Responsive Menu
Add more content here...
Responsive Menu
Add more content here...
Ateva Technologies

IPES IES 5416T

16 10/100TX + 4 10/100/1000T X-coded L2+ 8 PoE at/af Industrial Managed Switch w/ enhanced G.8032 Ring & PTP

  • Support PTPv2 two-step transparent clock @ 4 10/100/1000T ports
  • EN50155/61373/45545-2 verification
  • IEEE802.3at/af up to 30W per port; PoE management incl. detection and scheduling
  • Optional 12V input boost to 54V output for IEEE802.3at/af max.80W
  • Optional 72V input steps down to 48V output for IEEE 802.3at/af max.80W
  • Optional 110V input to 48V output for IEEE 802.3at/af max.80W
  • Enhanced G.8032 ring protection < 20ms with auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP
  • Relay contact & environmental monitoring
  • Miss-wiring avoidance; Repowered auto ring restore (node failure protection)
  • IP67/IP54 housing; User friendly UI, including auto topology drawing; Complete CLI
  • N-key configurator** for upgrading, auto/editable configuration back up and restoration without computer
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port&VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3, IPv6, SMS
OVERVIEW
Lantech IPES-5416T-8-X (IP67/IP54) is a high performance L2+ (Gigabit uplink) switch with 16 10/100TX(d-coded) + 4 10/100/1000T(x-coded) w/8 PoE 802.3af/at Injectors by M12 provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including train coupling ring , and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.
Lantech IPES-5416T-8-X (IP67/IP54) features hardware-based PTP IEEE1588 v2 two-step function which can allow 4 10/100/1000T uplinks to synchronize the network with precise accuracy.
Lantech IPES-5416T-8-X (IP67/IP54) supports IEEE802.3at/af standard which can feed HI-power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, High power wireless AP etc. The advanced PoE management includes PoE detection and scheduling besides the regular PoE per port status. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status can remotely On/Off the power and display information of voltage, current, watt and PoE temperature.
The Lantech IPES-5416T-8-X (IP67/IP54) series is designed with various dual power input at 12/24/48VDC input (12V model), 72V input to feed 48V PoE (72V model). The 110V model can accept dual 110V to feed 48V POE and feed PoE power 48V at PoE budget max 80W. Featured with relay contact alarm function, the IPES-5416T-8-X (IP67/IP54) is able to connect with alarm system in case of power failure or port disconnection events. The IPES-5416T-8-X (IP67/IP54) also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
The IPES-5416T-8-X (IP67/IP54) also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5416T-8-X (IP67/IP54) is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 and relay agent function (port&vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.
Lantech InstaConfig software** provides easy configuration for mass deployment. The configuration file can also be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The built-in watchdog design can automatically reboot the switch when cpu is found dead.
The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5416T-8-X (IP67/IP54) much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The complete CLI enables professional engineer to configure setting by command line.
Lantech IPES-5416T-8-X (IP67/IP54) features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 16 MSTI. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.
The configuration file of Lantech IPES-5416T-8-X (IP67/IP54) can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The optional N-key configurator offers firmware upgrade, auto/editable configuration back up and restoration without computer by adjusting the DIP switch.
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
In case of event alarm, the IPES-5416T-8-X (IP67/IP54) will immediately send an email & SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 1DI and 1DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
The built-in environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.
The IPES-5416T-8-X (IP67/IP54) is designed to meet with critical network environment with IP67/IP54 aluminum enclosure and M12 connectors for water proof. It passed serious tests under extensive Industrial EMI and Safety standards. With EN45545-2 Fire & Smoke, and EN50155 verification, the IPES-5416T-8-X (IP67/IP54) is best for railway and vehicle applications. For more usage flexibilities, IPES-5416T-8-X (IP67/IP54) supports wide operating temperature from -40°C to 75°C.
The optional bypass relay is set to bypass the switch to the next one in 4ms when power is off in order to protect the network from crashing. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. The bypass is also activated when detecting the CPU watchdog is ON.
FEATURES
  • 16 10/100TX d-coded + 4 10/100/1000T x-coded w/8 PoE 802.3af/at Injectors Industrial Managed IP67 M12 Switch (Total 20 Ports Switch)
  • EN45545-2 Fire & Smoke, EN50155 and EN61373 shock/vibration verification
  • IEEE802.3at/af feeding power up to 30W per PoE port at 45~56VDC at port 1-8
  • PoE management including PoE detection and scheduling for PD (power devices)
  • 12V model can accept dual 12V power input and boost to 54V for PoE 802.3at/af max 80W budget
  • 72V model can accept dual 50.4~90V power input and feed 48V for PoE at/af at max 80W budget
  • 110V model can accept dual 43V~137.5V inputs and feed 48V for PoE at/af at max 80W budget
  • IEEE 1588 PTP v2 two-step at 4 Giga ports
  • Back-plane (Switching Fabric): 11.2Gbps
  • 16K MAC address table
  • 10KB Jumbo frame supported on all ports
  • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
  • Enhanced G.8032 Ring protection in 20ms < 256 switches
    • Support various ring/chain topologies, including train dynamic coupling ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Co-exist with RSTP on different ports
  • Provides EFT protection ±2000 VDC for power line.
  • Supports ±6000 VDC Ethernet ESD protection
  • LACP load balancing to distribute the load*
  • Built-in RTC (Real Time Clock) to keep track of time
  • Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority
  • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy
  • 4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*
  • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server for Port&Vlan based DHCP distribution
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress packet filter and egress rate limit
    • Broadcast/multicast packet filter control
  • Relay alarm output system events
  • Miss-wiring avoidance
    • LED indicator
    • Email, traps, or SMS notification
  • Repowered auto ring restore
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
  • System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • Management access control with priority
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
  • Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow
  • Multicast VLAN registration* for metro video
  • IGMPv1,v2,v3 with Query mode for multi media; GMRP**
  • N-key** configurator for firmware upgrade, auto/editable configuration back up and restoration
  • Watchdog design to auto reboot switch CPU is found dead
  • Built-in environmental monitoring for system input voltage, current, ambient temperature
  • Supports DIDO (Digital Input/Digital Output)
  • IP67 aluminum housing with wall mount and DIN rail** design; IP54 aluminum housing with wall mount design
  • Bypass protection** – Bypass failed switch caused by power failure of switch to protect network intactness

With Bypass Protection

P/N Model name Description
8361-6179 IPES-5416T-8-X-67-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection
8361-6049 IPES-5416T-8-X-67-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection
8361-6189 IPES-5416T-8-X-67-12V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6059 IPES-5416T-8-X-67-12V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6159 IPES-5416T-8-X-67-72V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
w/ 1 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6069 IPES-5416T-8-X-67-72V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
w/ 2 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6178 IPES-5416T-8-X-54-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection
8361-6048 IPES-5416T-8-X-54-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection
8361-6188 IPES-5416T-8-X-54-12V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6058 IPES-5416T-8-X-54-12V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6158 IPES-5416T-8-X-54-72V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
w/ 1 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6068 IPES-5416T-8-X-54-72V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
w/ 2 pair GigaT bypass protection; 50.4~90V dual input 80W PoE

Without Bypass Protection

P/N Model name Description
8360-6179 IPES-5416T-8-X-67 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C
8360-6189 IPES-5416T-8-X-67-12V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
12V~48V dual input; 80W@12V; 120W@24V
8360-6159 IPES-5416T-8-X-67-72V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
50.4~90V dual input 80W PoE
8360-7379 IPES-5416T-8-X-67-110V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
43~137.5V dual input 80W PoE
8360-6178 IPES-5416T-8-X-54 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C
8360-6188 IPES-5416T-8-X-54-12V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
12V~48V dual input; 80W@12V; 120W@24V
8360-6158 IPES-5416T-8-X-54-72V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
50.4~90V dual input 80W PoE
8360-7378 IPES-5416T-8-X-54-110V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
43~137.5V dual input 80W PoE

Optional accessories

odel name Description
ECONM23-5P(F)70CM CABLE M23 power cable 90 degree angle, 70cm, 5 pin, Made in Taiwan
ECONM23-5P(F)70CM CABLE-C M23 power cable 90 degree angle, 70cm, 5 pin, Made in China
ECAB124030MJS 4 Pin M12 RJ45 Male 3 Meters; STP Cable
ECABM12X83MSTP 8 Pin M12 X-coded RJ45 Male 3 METER, STP CABLE w/ Shielding

Training on demand available

SPECIFICATIONS

Hardware Specifications

Standards IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
Switch Architecture Back-plane (Switching Fabric): 11.2Gbps
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port
CPU Marvell 800Mhz
RAM 256M Byte
Flash 128M Byte
Mac Address 16K MAC address table
Jumbo frame 10KB on all ports
Connectors 10/100TX: 16 x ports M12 4-pole D-coded with Auto MDI/MDI-X function
10/100/1000T: 4 x ports M12 8-pole X-coded with Auto MDI/MDI-X function
RS-232 connector: 1 x M12 5-pole A-coded
Power Input connector : 1 x M23 5-pole A-coded
Relay contact : 1 x M12 5-pole A-coded
Network Cable 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
Bypass Protection** High-speed optical switching (<4ms)
Minimal insertion loss (Max 1.6dB as Bypass Mode)
Protocol CSMA/CD
LED Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), RM (Green)
Ethernet port: Link/Activity (Green), Speed (Green); Optical fiber: Link/Activity (Green)
DI/DO 1 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
1 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating Humidity 5% ~ 95% (Non-condensing)
Operating Temperature -40°C~75°C / -40°F~167°F
(72V model: -40°C~60°C / -40°F~140°F)
Storage Temperature -40°C~85°C / -40°F~185°F
Power Supply 44~57VDC on standard model
9.5~57VDC on 12V model
50.4~90VDC on 72V model
43~137.5VDC on 110V model with input isolation
PoE Budget 240W for 44~57V input
(55V input is recommended for 802.3at 30W applications)
80W for 12V input
120W for 24V input
80W for 72V/110V Input
PoE pin assignment M12 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W PoE at/ 15W PoE af.
Power Consumption Max. 13W 12V~48VDC input
Max. 16W 72VDC/110VDC input
Case Dimension IP67 Aluminum case
285mm(W)x200mm(H)x84.4mm(D)
IP54 Aluminum case
250mm(W)x179mm(H)x82mm(D)
Weight 2.1kgs(IP67) 1.8kgs(IP54)
Installation IP67 model: DIN Rail** and Wall Mount Design
IP54 model: Wall Mount Design
EMI & EMS FCC Class A,
CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11
Stability Testing IEC60068-2-32 (Free fall), EN61373 (Shock and Vibration)
MTBF 217,019 hrs
Verifications & report EN50155/EN50121-3-2/EN50121-4 verification
EN45545-2 R24/R25 (EN ISO 4589-2, EN ISO 5659-2, NF X70-100-1 & 2) Fire & Smoke verification
Safety EN 60950-1 (Standard model and 110V model)
Warranty 5 years

Software Specifications

Management SNMP v1 v2c, v3/ Web/Telnet/CLI
SNMP MIB RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
LLDP MIB*
RSTP MIB*
Private MIB
ITU G.8032 Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)
Support various ring/chain topologies
Includes train dynamic coupling ring
Enhanced G.8032 ring configuration with ease
Co-exist with RSTP on different ports
PoE Management
  1. PoE Detection to check if PD is hang up then restart the PD
  2. PoE Scheduling to On/OFF PD upon routine time table
  3. On/ Off, voltage, current, watts, temperature
PTP v2 Support hardware-based IEEE1588 PTP v2, End to End (2-step) and Peer to Peer (2-step) modes in Transparent Clock, with 4 10/100/1000T
User friendly UI
  1. Auto topology drawing
  2. Topology demo
  3. Auto configuration for G.8032(auto mode) for single ring
  4. Complete CLI for professional setting
Port Trunk with LACP LACP Port Trunk: 8 Trunk groups/Maximum 16 trunk members
LLDP Supports LLDP to allow switch to advise its identification and capability on the LAN
CDP Cisco Discovery Protocol for topology mapping
Environmental Monitoring System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status
VLAN Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP(256 groups)**, QinQ*
IPv6/4 Present
Spanning Tree Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree
Quality of Service The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP
Class of Service Support IEEE802.1p class of service, per port provides 8 priority queues
QoS by VLAN Tagged QoS by VLAN for all devices in the network
IP Security Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
Login Security Supports IEEE802.1X Authentication/RADIUS
Port Mirror Support 3 mirroring types: “RX, TX and Both packet”
Network Security Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
Ingress/Egress ACL L2/L3
SSL/ SSH for Management
HTTPS for secure access to the web interface
TACACS+ for Authentication
IGMP Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP**
MVR Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
Bandwidth Control Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.
RTC Built-in Real Time Clock to keep track of time always
Flow Control Supports Flow Control for Full-duplex and Back Pressure for Half-duplex
System Log Supports System log record and remote system log server
SMTP/Text SMS Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile
Relay Alarm Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V
Protection
  1. Miss-wiring avoidance
  2. Repowered auto ring restore
  3. Loop protection
SNMP Trap Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. PoE ping failure
  7. Power failure
  8. Environmental abnormal
DHCP Provide DHCP Client/ DHCP Server/DHCP Option 82/ DHCP Option 82 server/ Port based&VLAN based DHCP distribution (DHCP relay agent)
Mac based DHCP Server Assign IP address by Mac that can include dumb switch in DHCP network
DNS Provide DNS client feature and support Primary and Secondary DNS server.
SNTP Supports SNTP to synchronize system clock in Internet
Firmware Update Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
N-Key Configurator** RJ45 dongle for firmware upgrade, auto / editable configuration backup/restoration
Configuration
upload and download
Supports text configuration file for system quick installation
IfAlias Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface
*Future release
**Optional

PB-LSZ-CHB3

Pince pour mesure de courants de fuite

 

La pince PB-LSZ-CHB3 permet la mesure de courants de fuite; eg : fuite, Measures leakage currents, e.g. leakage and fault currents, and current pick-up of instruments without breaking the circuit. Measurements according to DIN VDE 0701/0702 and the German BetrSichV (BGV A3, VBG 4).

  • D’une fiabilité redoutable, cette pince détecte des courants de fuite très faitble, résultant de problèmes de champs ElectroMagnétique ( EMC )

    Fonctionnalités PB-LSZ-CHB3:

  • Mesure de courants de fuite
  • Mesure de courants différentiels
  • Mesure de résistance et tension
  • Fréquence de mesure pour Courant alternatif / Tension  40 Hz…1 kHz
  • Test de continuité accoustique
  • MIN/MAX et mesure relative
  • Sélection manuel de la plage de mesure
  • data hold intégré
  • Affichage bar graph additionnel
  • Ouverture de la pince : ouvrant jusqu’à : 30 mm
  • Extension automatique

Pince numérique pour la mesure des coutants de fuite :  2 batteries 1.5 V IEC LR6, housse de protection, cables de mesure (1 x rouge, 1 x noir) et manuel utilisateur.

Ref : ATV-DDA-ZZ-004010 ( anciennement :PB-LSZ-CHB3 )

pb-lsz-chb3

WireXpert 4500

Ethernet tester : WireXpert 4500

Ethernet Tester : WireXpert 4500 le premier du marché à obtenir le certificat : Bel Stewart Category 8.2 / Class ll .

Soyez le premier a tester et vérifier l’installation de votre Datacenter jusqu’à la vitesse de 40GB/s !!

Le WireXpert, avec sa gamme de mesure inégalée de 2 500 MHz, est le premier appareil de certification de câbles capable de certifier les systèmes de câblage les plus performants dans les réseaux d’entreprise et les centres de données. Les installateurs de câbles obtiennent un gain de productivité significatif grâce à la vitesse de test et à la facilité d’utilisation de WireXpert. Avec le test de certification pour le câblage en cuivre classe FA et CAT8, ainsi que pour le câblage par fibre optique MPO, SM, MM et MMEF, le WireXpert est prêt pour 40G et au-delà.

  • Works now and in the future. Supporting measurements up to 2,500 MHz, WireXpert already now complies with the upcoming CAT8 standards
  • Unsurpassed measurement accuracy reveals hidden faults in the telecommunication cabling
  • Ultra-fast measurement and certification procedures coupled with practical features speed-up your work flow. It only takes a few seconds per link to perform the required measurements and analysis
  • Highly accurate results and professional reporting provide customer-ready output
  • Intuitive user interface on a large color LCD touchscreen makes it easy for anyone to operate the unit
  • You open up new potential applications. Universally expandable with a variety of adapters

Copper testing

Certification Testing TIA 568-C.2 CAT5e, 6, 6A, draft CAT8
ISO/IEC 11801, EN 50173 Class D,E,EA,F,FA
draft Class I and Class II Permanent link and channel
Autotest time – CAT6A
Autotest time – Class FA
Max cable length for dual ended autotest 500m
Insertion Cycles Channel: 10,000 typical
Permanent link: 5,000 typical
Testparameters As specified in TIA 1152, IEC 61935-1
Wiremap
Loop Resistance 0 to 40 Ω, ±0.1 Ω
Length 0 to 500m, ±0.5m (dual ended testing)
Propagation Delay and Delay Skew 0 to 5000 ns, ±1 ns
Attenuation 0 to 70 dB, ±0.1dB
Pair-to-Pair and Power-Sum NEXT 0 to 85 dB, ±0.2 dB
Pair-to-Pair and Power-Sum ACRF 0 to 85 dB, ±0.2 dB
Return Loss 0 to 40 dB, ±0.2 dB
ACRN, PSACRN 0 to 85 dB, ±0.5 dB
Advanced Diagnostics Time-domain fault Locator for RL and NEXT
Measurement accuracy Exceeds TIA 1152 Level IIIe, IEC 61935 level IV
Measurement frequency range 1- 2,500 MHz

General Specifications

Interfaces Probe Interface, RJ-45 Ethernet, USB host and device, talkset, power jack
Display 6“ industrial LCD, touch sensitive area on both units
Enclosure Ruggedized plastic with rubber over-mold, withstands 1.5m drop test on hard surface
Remote unit abilities View test results, save tests, start autotest
Power supply AC 100-240V to 12V, 3A power adapter
Input over-voltage protection Protected against Telco voltages
Battery Removable and rechargeable Li-Ion
Battery Capacity >8 hours continuous operation
Internal Storage Capacity 2000 copper test results with full plot information
External Storage USB Flash Drive
Dimensions 232 X 126 X 87 mm(9.1 X 5.0 X 3.4 inch)
Weight Approx. 1.4 kg (3.0 lb) / unit
Supported Languages Chinese, Czech, English, Finnish, French, German,
Italian, Japanese, Korean, Polish, Portuguese,
Russian, Spanish, Swedish, Turkish
Calibration period 1 year

Environmental

Operating Temparature 0 to 40 °C
Storage Temperature -20 to 60 °C
Relative humidity 10% to 80%
  • WX4500-FA
  • 2x Main certification test units
  • 2x Li-Ion batteries
  • 2x Stylus with Cords
  • 2x Display protection cover
  • 2x CAT 6A Permanent Link Adapter
  • 2x CAT 6A Permanent Link Test Cords
  • 2x CAT 6A Channel Adapter
  • USB Stick with reference manual and eXport software
  • 2x Talk sets
  • 2x AC Power Adapters
  • 2x Country Specific Power Cords
  • Calibration certificate
  • Quick Reference Guide
  • Carry bag

WireXpert4500 settings

TACC Software

TACC Software

tacc_ht_d_en_160401_300

TACC :Central Management of HART Field Devices With Emerson AMS Suite

The TACC software product extends Emerson’s AMS functionality by providing central access to HART devices via a PROFIBUS network. For this, TACC supports the use of Remote I/Os from all leading manufacturers, such as ABB, Altus, Pepperl+Fuchs, Siemens, STAHL, Turck and Wago. In combination with TH LINK PROFIBUS, the solution allows the parallel monitoring of the PROFIBUS network and the connected field devices.

Efficient Use of Field Devices in the Process Industry :  TACC is right for you

  • Fast plant commissioning, fast replacement of defective devices
  • Simple remote device parameterization
  • Central management of all device parameters
  • Comprehensive monitoring of process-critical devices
  • Automatic creation of plant documentation

Additional Benefit From Integrated PROFIBUS Monitoring

  • Use of TH LINK PROFIBUS for simultaneous PROFIBUS diagnostics
  • TH LINK PROFIBUS optionally expandable by TH SCOPE diagnostics software

Ease of Use

  • Seamless integration into Emerson AMS
  • Accessibility of HART devices in familiar tool environment
  • Support for wide variety of different network accesses
PROFIBUS Access
(Max. 12 Mbit/s)
  • TH LINK PROFIBUS
  • PROFIusb
  • PBpro ETH
  • PBpro PCI
  • PBpro PCI Express
  • PBpro CompactPCI
  • PBpro PC104plus
  • PROFI104
Supported Remote I/O Stations
  • S800, S900 (ABB)
  • Ponto 5064, Ponto 5065 Redundant (Altus)
  • MTL8000 (MTL)
  • LB, FB, RPI (Pepperl+Fuchs)
  • ET 200M, ET 200iSP (Siemens)
  • I.S.1 (STAHL)
  • BL20, Excom (Turck)
  • 750-333, 750-833 (Wago)

(For detailed descriptions of supported components, see Release Note)

Supported Operating Systems Windows 7, Windows 8 (English, 32 Bit), Windows Server 2003, Windows Server 2003 R2, Windows Server 2008, Windows Server 2012
System Requirements
  • Emerson AMS 11.5, AMS 12.5, AMS 13
  • Adobe Reader 8.0 or higher for reading the documentation
VAA-NM-023001 TACC (free of charge)

Scope of Delivery

Software TACC V3.1 (by download)
Documentation Installation Guide, User Manual for HART Over PROFIBUS, Release Note

Additional Products and Services

GEA-JN-003006 TH LINK PROFIBUS
PBPro USB PROFIusb
DEL-NN-012311 PBpro ETH, single-channel (different versions)
PB-PRO1-PCI / PB-PRO1-PCI/LP1 PBpro PCI Master/Slave, single-channel
PB-PRO1-PCIE / PB-PRO1-PCIE/LP1 PBpro PCI Express Master/Slave, single-channel (different versions)
PB-PRO1-CPCI PBpro PROFIBUS CompactPCI interface card
PB-PRO1-PC104+ PBpro PC/104plus card (different versions)
PB-PC104-MS PROFI104 Master/Slave (different versions)

No training on this product

Les personnes intéressés par ce produit, peuvent aussi être intéressés par :

CANPro USB

canprousb_d_en_160801_201

CANPro USB : Interface USB « High Speed » vers interface CAN, pour une utilisation mobile

CANPro USB équipe un PC, un ordinateur portable avec des preformances optimales, des réponses rapides de l’interface CAN. Le CANPro USB correspond à de larges utilisations de CAN et CANOpen, comme le contrôle, la mesure, la confirguration et l’analyse de tache. Il est disponible dans une version « Heavt Duty »

Un débit de données élevé grâce à un temps de réponse court

  • Standard USB 2.0 « High Speed »
  • Une des interfaces CAN les plus rapides du marché
  • Processeur et rapidité optimisé par firmware. conçu pour 100% de charge de bus à 1 Mbit/s
  • Débit de données élevé, grâce à un temps de réponse de 100 μs à 500 μs
  • Convient à une large gamme d’applications, incluant les applications ou le timing est une variable critique
  • Très simple d’utilisation
  • Status USB et CAN affichés par LED
  • Installation facile par connexion du cable USB vers le PC et connecteur ‘D-Sub’ vers réseaux CAN
  • Aucune alimentation électrique nécessaire.

Convient pour des applications « statiques » et « mobiles »

  • Petit et robuste, désign métalique qui convient à un usage de tout les jours
  • S’adresse aussi bien a des applications mobiles que standards
  • Une version « Heavy duty » disponible offrant un cable USB fixé et sécurisé et un kit de montage sur PC. Idéal pour applications industrielles en environnement dur

Fonctionalité facile supportant une large variété d’utilisations

  • Intégration facile dans vos applications CAN
  • APIs basé sur  C et .NET
  • Support d’une FIFO et d’un mode « objet buffer »
  • API Client CANopen gratuit, pour intégration d’applications comme le contrôle et la mesure, la configuration et l’analyse
CAN Protocol and Available APIs CAN V2.0 (11/29 Bit-IDs)
CAN API
CANopen Client API
Bus Connection
Connector 9-pin D-sub male
Galvanically Isolated Yes
Physical Layer ISO 11898-2 (CAN High Speed)
PC Interface USB 2.0 High Speed, 480 Mbit/s
Indicators
USB LED USB status
CAN LED CAN status
Operation Temperature 0 °C … +55 °C (standard version) / -20 °C … +70 °C (heavy duty version)
Storage Temperature -20 °C … +70 °C (standard version) / -20 °C … +70 °C (heavy duty version)
Relative Humidity < 90 %, non-condensing
Dimensions 74 mm x 55 mm x 26 mm
Power supply
Supply Voltage 5 VDC (±5 %) via USB connector
Current Consumption Typically 200 mA
Drivers Available for Windows XP, Windows 7, Windows 8, Windows 10, Linux
Conformity
DUL-OO-012410 CANpro USB (Version standard)
DUL-OO-012411 CANpro USB (Version  » renforcée « )

Scope of Delivery

Hardware (Version Standard ) CANpro USB ( version standard ), Cable USB
Hardware (Heavy Duty Version) CANpro USB (heavy duty version), lockable USB cable with cable connector and mounting kit
Software Drivers, APIs, sample programs on CD-ROM
Documentation Manual on CD-ROM

Contactez nous pour des formations CAN – Formation disponible en langue Anglaise uniquement

BC-502-PB

Le BC-502-PB – pour PROFIBUS DP

BC-502-PB : moniteur de reseau PROFIBUS DP, pour une analyse de vos réseaus PROFIBUS DP : 24H/24

Moniteur Réseau PROFIBUS DP

PROFIBUS DP Moniteur (BC-502-PB)

Disponibilité maximale grâce au moniteur BC-502-PB, de bus PROFIBUS DP

Le moniteur PROFIBUS DP ( BC-502-PB) est un « inspecteur » de reseaux. Il analyse de façon continue, les données qui transite sur le réseau PROFIBUS DP..Dans le cas ou l’outils detecte un echange critique qui pourrait amener à une panne du réseau, il génère automatiquement une notification de disfonctionnement et une action préventive peut être effectué.

  • Prévient de pertes de production dans le cas de problèmes de bus
  • Permets la planification des maintenance réseaux
  • Facile a utiliser, via une interface Web intégré
  • Etat de chaque esclave sur le bus PROFIBUS DP

le BC-502-PB permet la détections rapide des problèmes de bus

Le moniteur PROFIBUS se fixe dans un rack de contrôle, ( Rail DIN ). On dispose d’un moniteur par ligne de bus PROFIBUS, indépendement du nombre physique de segments a analyser. Le BC-502-PB détecte les déteriorations de la communication du bus et les rapporte. Cela permet d’établir une stratégie  de maintenance, qui réduit les interventions des équipes, seulement en cas de besoin. Les ressources maintenance sont alors optimisées.

Le BC-502-PB permet une lecture facile et simple.

Aucun changement d’adresse ni même de programmation de la PLC n’est nécessaire., lors de l’installation du moniteur PROFIBUS. La configuration et la visualisation sont fait via le réseau, grâce à une interface web intégrée.  le debug, l’analyse des problèmes demande une connaissance minimum des réseaux PROFIBUS.

 

Le BC-502-PB  avertit des pannes prochaines….

En se connectant sur un segment PROFIBUS, le moniteur PROFIBUS détecte automatiquement, la vitesse de transmission ( Baud Rate ) et démarre instantanément l’analyse du réseau PROFIBUS DP. Il détermine les temps de cycles et compte les événements critiques. Les événements critics sont : les erreurs de trames, redémarrage, les messages de diagnostics.. De cette manière, les détériorations lentes du réseau, dû à l’age de l’installation, sont rapidement détectées. Quand le nombre d’erreurs dépasse une limite par unité de temps, le moniteur PROFIBUS envoie une alarme à la PLC via un contact, ou ( optionel) vers le réseau Ethernet. Les 100 dernières alarmes sont stockées sous forme de liste. Dans le cas d’une apparition d’alarmes, le BC-502-PB permet de retrouver l’historique de la période en question. Le fichier trace peut etre analysé ultérieurement grâce à l’outil PROFIBUS Diagnostics Suite.

 

Power Supply DC 24 V +/–20%, typ. 0.3 A, max. 1 A
PROFIBUS PROFIBUS Protocols: DP, DPV1, FMS, MPI; Connection: 9-Pin D-Sub, Baud Rates: 9.6 Kbit/s .. 12 Mbit/s
Ethernet 100BASE-TX, 10BASE-T, Connection: RJ45, IP Address: Manually or via DCHP
RS232 Reserved
USB Only available with BC-502-PB/CL Option
Control Signals Potential-free Contact, 3 Inputs DC 24 V, Active High
Dimensions HxWxD: 131 x 47 x 111 mm
Weight Approx. 0.4 kg
Mounting 35 mm DIN Rail
Protection Class IP20
Operating Temperature 5 °C to 55 °C
Storage Temperature –20 °C to 70 °C
Conformity CE, FCC, VCCI
Display & Parameterization Via Integrated Web Interface
Snapshot Analysis Via PROFIBUS Diagnostics Suite PC Software, see separate Data Sheet
BC-502-PB PROFIBUS Monitorr for Continuous Bus Monitoring and Condition-based Maintenance of DP/DPV1/FMS/MPI, DIN Rail Mounted, External 24 VDC Power Supply Required, Signaling
Contact, Control Inputs, Ethernet 10/100BASE-T(X),RJ45, Integrated Web Server, User Manual, PB-DIAG-SUITE Analysis Software (See seperate Tab.)
BC-502-PB-START PROFIBUS Monitor Start Package Consisting of BC-502-PB, BC-131-PB, AC Adapter/Cable, Patch/Crossover Cable and Carrying Case

Additional Products and Services

BC-131-PB Optional Active Connection Cable for Hassle-free Integration into Existing or Running Installations Without Recabling or the Disturbances Caused by a Spur Cable, 3m Length, Bus-powered Internal Repeater
BC-502-PB/CL “Comfort Line” Option, Allows Full-Featured Protocol Analysis via USB, Supplied as Activation Code
BC-502-PB/SNMP “Premium Line” Option, Provides SNMP Network Interface for Measurement Data, Supplied as Activation Code
BC-502-PB/CLP “Comfort Line Plus” Option, Allows Full-featured Protocol Analysis via USB and Provides SNMP Network Interface for
Measurement Data, Supplied as Activation Code
TRA-PB-TECH PROFIBUS Technology Training, 2-Day
TRA-PB-TS PROFIBUS Troubleshooting Training, 3-Day

Universal Software for All Diagnostic Tools of the bus check Family

PC software for performing, evaluating and managing tests of bus physics, bus communication and cabling in PROFIBUS networks. The application is extremely easy to use, with a quick test available at a click of the mouse.

One Software for All Diagnostic Products

  • Comprehensive analysis of PROFIBUS DP and PROFIBUS PA networks
  • Diagnostic functionality available depending on connected test tool
  • License-free use on any number of PCs – no activation required

Suitable for the Fieldbus Novice

  • Bus test initiated with a single mouse click
  • Clear, easy-to-read display of test results
  • Separate expert mode providing in-depth diagnostic features for network specialists

Functionality for All Diagnostic Tasks

  • Continuous display of current bus status in status bar
  • Overall bus health indicated by traffic light symbols for bus physics and bus communication
  • Detail views with additional diagnostic information, also for advanced analyses by experts
  • Testing of bus and connected devices via integrated master simulator without configuration or parameterization
  • Generation of test reports for acceptance testing of PROFIBUS installations

Functionality of the Test Tools

Technical Data

Operating Systems:
PC Hardware*
RAM 500 MB for Windows XP
1 GB for Windows 7, Windows 8
Processor 1 GHz for recording at baud rates up to 1.5 Mbit/s
2 GHz for recording at baud rates over 1.5 Mbit/s
Screen Resolution 1024 x 768 pixels (XGA)
USB Interface 2.0
Supported Operating Systems Windows XP, Windows 7, Windows 8

* The above minimum requirements are only general guidelines. Requirements may vary depending on the PC/notebook used.

Order Number

PB-DIAG-SUITE PROFIBUS Diagnostics Suite

Scope of Delivery

Software PROFIBUS Diagnostics Suite, PC software on CD-ROM for PROFIBUS Tester 5 BC-700-PB, PROFIBUS Tester 4 BC-600-PB and PROFIBUS Monitor BC-502-PB
Documentation Manual “Getting Started”

Additional Products and Services

TRA-PB-TECH PROFIBUS Technology Training, 2 Days
TRA-PB-TS PROFIBUS Troubleshooting Training, 3 Days

Fieldbus Shield Digital Leakage Current Clamp – Locating EMC Problems

Measures leakage currents, e.g. leakage and fault currents, and current pick-up of instruments without breaking the circuit. Measurements according to DIN VDE 0701/0702 and the German BetrSichV (BGV A3, VBG 4).
  • Reliably Detects Even Very Small Improper Shield Currents Resulting from EMC Problems.
Fieldbus Shield Digital Leakage Current Clamp

Functionality

Included in Package

  • Leakage current measurement
  • Differential current measurement
  • Voltage and resistance measurement
  • Frequency range for AC current / voltage 40 Hz…1 kHz
  • Acoustical continuity test
  • MIN/MAX and relative value measurement
  • Manual selection of the measurement range
  • Integrated data hold
  • Additional analog bar graph display
  • Clamp opening 30 mm
  • Auto power off
Digital leakage current clamp, 2 batteries 1.5 V IEC LR6, carrying case, measuring cables (1 x red, 1 x black) and user manual.

Order Number:

PB-LSZ-CHB3


Interface for Providing an Access Point to Test PROFIBUS Networks if the D-sub Connectors have no Service Socket or if the Devices are Connected via Terminal Block

Provides an access point for testing PROFIBUS networks if the D-sub connectors have no service socket or if the stations are connected via terminal block.
  • Allows Testing the Bus During Operation
  • Exchange of Bus Devices at the Beginning or End of the Bus Without Causing Problems on the Bus
D-Sub Service Interface

Application

The service interface is top hat rail mounted. An external 24 VDC power source is required for power supply to the terminating resistor in the PROFIBUS connector included in the package. The service interface can thus be used as an active bus termination at the beginning or end of the bus. If the PLC allows dropping and adding bus stations on the live bus, the service interface offers the possibility to exchange the first and last bus stations without causing problems on the bus. Application example:Application Example D-Sub Service Interface

Included in Package

PBMB adapter and 90° angled PROFIBUS connector with switchable terminating resistor, strain relief and screw terminal technology.

Order Number:

BC-PBMB-PB-S


Interface for Providing an Access Point to Test PROFIBUS Networks With M12 Connectors

Provides an access point for testing PROFIBUS networks with M12 connectors.
  • Allows Testing the Bus During Operation
M12 Service Interface

Application

The service interface is inserted between two bus stations. When not in use, the service output of the T piece is closed with an end cap. At baud rates of 1.5 Mbit/s or higher, use the supplied cable to ensure that the required minimum distance between bus stations is maintained. Application example:

Application Example M12 Service Interface

Downloads

Included in Package

T piece (protection class IP68) with end cap and a 1 m DP cable fitted with a male/female M12 connector on each end.

Order Number:

BC-M12DP-PB


RUT-900

RUT-900

RUT-900 : Routeur 3G Industriel, VPN, Firewall et double cartes SIM

Routeur 3G (21Mbps/5.76Mbps), double carte SIM, avc Wifi ett 4 ports Ethernet ( 100Mb/s)

Le RUT-900, est un routeur 3G,  d’une grande fiabilité, et sécurisé, dédié aux applications industriels, Ce routeur delivre des performances exceptionnelles, pour des missions Telecom critiques, Le routeur 3G  RUT-900, est équipé avec une double carte SIM, pour les situations de redondance.. Des connecteurs SMA externes, permettent l’utilisation d’ antennes aux choix.

TECHNOLOGY

  • 3G –Up to 21 Mbps i
  • 2G –Up to 236.8 kbps i
  • Wi-Fi –Up to 300 Mbps i
  • Ethernet –4 ports i
  • SMS i

HARDWARE

  • Mobile antenna type –2 x SMA
  • Wi-Fi antenna type –2 x RP-SMA
  • Input voltage –9 – 30 VDC
  • SIM card slots –2
  • Operating temperature range –-40 °C to 75 °C
  • Storage temperature range –-45 °C to 80 °C
  • Power consumption –< 7W
  • Mounting options –Din rail
  • LED indication –Power, status, signal, ethernet

FIRMWARE

  • emote configuration over SMS i
  • Bridge mode i
  • Automatic and manual operator selection i
  • Static routes i
  • PPPoE i
  • NTP i
  • Wireless Hotspot i
  • Wireless Client i
  • Wireless AP i
  • Ping reboot i
  • Periodic reboot i
  • Realtime graphs i
  • Backup WAN i
  • Mobile Traffic counter i
  • Connection status overview bar i
  • Configuration backup/restore i
  • VRRP i
  • IPSec i
  • GRE Tunnel i
  • OpenVPN i
  • PPTP i
  • L2TP i
  • SNMP i
  • SNMP trap i
  • Send/receive SMS i
  • Status via SMS i
  • SMS reboot i
  • 3G/4G enable/disable via SMS i
  • Wireless on/off via SMS i
  • OpenVPN ON and OFF via SMS i
  • Web Filter i
  • Mobile on Demand i
  • Mobile Data Limit i
  • Configuration Profiles i
  • Event logging i
  • QoS i
  • Restore point i
  • Call Utilities i
  • SIM switch i
  • FOTA (Firmware Over The Air) i
  • Event reporting (via Email/SMS) i
  • Integrated speed test i
  • Network Scanner with Topology display i
  • Disable Roaming i
  • SMS gateway i
  • OSPF i
  • Access control safety i
  • SIM Idle protection i
  • VLAN i
  • CLI i
  • Firewall i
  • IP/MAC filter i
  • TR-069 i
  • DHCP server i
  • Dynamic DNS i
  • RMS support i
  • HSDPA 21 Mbps DL and 5.76 Mbps UL
  • IEEE 802.11b/g/n WiFi with 2×2 MIMO up to 300 Mbps
  • OpenVPN, PPTP, L2TP, IPsec, VRRP, GRE Tunnel
  • SMS Control, WiFi Hotspot, Mobile on Demand, Backup WAN
  • Four Ethernet ports
  • Durable aluminum housing
  • External antennas
  • Dual SIM
  • Dual FW image
  • HSDPA 21 Mbps DL and 5.76 Mbps UL
  • IEEE 802.11b/g/n WiFi with 2×2 MIMO up to 300 Mbps
  • OpenVPN, PPTP, L2TP, IPsec, VRRP, GRE Tunnel
  • SMS Control, WiFi Hotspot, Mobile on Demand, Backup WAN
  • Four Ethernet ports
  • Durable aluminum housing
  • External antennas
  • Dual SIM
  • Dual FW image

IPES-3416DSFP

IPES-3416DSFP

IPES-3416DSFP

16 10/100TX PoE at + 4 Dual Speed SFP L2+ Industrial Managed Switch w/ ITU G.8032

  • Support IEEE802.3at/af up to 30W per port
  • PoE management incl. Detection and Scheduling
  • PTP 1588 v2 supported on fiber ports
  • Enhanced G.8032 ring protection < 20ms with easy configuration; Dynamic coupling ring; Aggregation ring*
  • Miss-wiring avoidance & Repowered auto ring restore (node failure protection)
  • User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port&VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, TACAS+*, ACL, IPv6, SMS
  • Environmental Monitoring for temp., voltage & current**

Lantech IPES-3416DSFP is a high performance L2+ (Gigabit uplink) switch with 16 10/100TX + 4 100/1000M SFP w/16 PoE 802.3af/at Injectors which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, enhanced mode for easy configuration and aggregation ring*, comprehensive QoS, QoS by VLAN, advanced security including ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.

Compliant with 802.3af/at standard, the Lantech IPES-3416DSFP is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPES-3416DSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.

Lantech IPES-3416DSFP features hardware-based PTP IEEE1588 v2 function which can allow 4 100/1000 SFP uplinks to synchronize the network with precise accuracy (under 1μs). It has RTC (Real Time Clock) inside that can keep track of current time.

The IPES-3416DSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-3416DSFP is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

DHCP option 82 and relay agent function (port&vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of police setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.

The user friendly UI, innovative auto topology drawing and topology demo makes IPES-3416DSFP much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IPES-3416DSFP supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.

Lantech IPES-3416DSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for ring/chain topologies which covers dynamic coupling ring & aggregation ring* protection. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. The enhanced mode and dynamic coupling mode ring configuration have never been easier. It supports MSTP that allows RSTP over Vlan for redundant links. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.

The configuration file of Lantech IPES-3416DSFP can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead. The USB slot allows user to backup/ restore configuration.

QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.

The IPES-3416DSFP DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-3416DSFP will immediately send an email & SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.

The optional environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.

The Lantech IPES-3416DSFP is designed with dual power supply at 48VDC. Featured with relay contact alarm function, the IPES-3416DSFP is able to connect with alarm system in case of power failure. The IPES-3416DSFP also provides ±4000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.

Lantech IPES-3416DSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.

The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.

      • 16 10/100TX + 4 100/1000M SFP w/16 PoE 802.3af/at Injectors (Total 20 Ports Switch)
      • Embedded 16 PoE Injectors IEEE802.3af/at function to feed power up to 30W@54V; 15W @ 48V per port for active operation
      • PoE management including PoE detection and scheduling for PD (power devices)
      • IEEE 1588 PTP v2 (under 1μs) on fiber ports
      • Back-plane (Switching Fabric): 11.2Gbps
      • 16K MAC address table
      • DDM to support SFP diagnostic function***
        • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
      • 9KB Jumbo frame supported on all ports
      • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
      • Enhanced G.8032 Ring protection in 20ms < 256 switches
        • Support various ring/chain topologies, including dynamic coupling ring& aggregation ring*
        • Enhanced G.8032 ring configuration with ease
        • Auto ring configuration(auto mode) for single ring
        • Co-exist with RSTP on different ports
      • Aggregation ring for ring redundancy and bandwidth combination*
      • Provides EFT protection ±4000 VDC for power line.
      • Supports ±6000 VDC Ethernet ESD protection
      • LACP load balancing to distribute the load*
      • Built-in RTC (Real Time Clock) to keep track of time
      • Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority
      • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy
      • 4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*
      • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**
      • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server for Port&Vlan based DHCP distribution
      • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
      • Bandwidth Control
        • Ingress packet filter and egress rate limit
        • Broadcast/multicast packet filter control
      • Relay alarm output system events
      • Miss-wiring avoidance
        • LED indicator
        • Email, traps, or SMS notification
      • Repowered auto ring restore
        • Ensure the switches in a ring to survive after power breakout is back
        • The status can be shown in NMS when each switch is back
      • TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade; USB for auto restore/backup
      • System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters
      • Security
        • SSL/SSH/ACL L2&L3
        • Port Security: MAC address entries/Filter/MAC-Port binding
        • IP Security: IP address security management to prevent unauthorized intruder.
        • Management access control with priority
        • Login Security: IEEE802.1X/RADIUS
        • HTTPS for secure access to the web interface
      • Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
      • Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow
      • Multicast VLAN registration* for metro video
      • IGMPv1,v2,v3 with Query mode for multi media; GMRP**
      • Factory reset button to restore setting to factory default
      • Watchdog design to auto reboot switch CPU is found dead
      • Optional environmental monitoring for system input voltage, current, ambient temperature
      • Supports DIDO (Digital Input/Digital Output)
      • IP30 metal housing with DIN rail and Wall-mount** design

Hardware Specifications

Standards IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX
IEEE802.3z Gigabit fiber
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
Switch Architecture Back-plane (Switching Fabric): 11.2Gbps
Packet throughput ability (Full-Duplex): 23.8Mpps @64bytes
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Fiber Ethernet port
CPU Marvell 800Mhz
RAM 256M Byte
Flash 128M Byte
Mac Address 16K MAC address table
Jumbo frame 9KB on all ports
Connectors 10/100TX: 16 x ports RJ-45 with Auto MDI/MDI-X function
Mini-GBIC: 4 x 100/1000 SFP socket with DDM
RS-232 connector: RJ-45 type
Power & P-Fail connector: 1 x 6-pole terminal block
DIDO : 1 x 6-pole terminal block
Network Cable 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
Optical Cable 1.25Gbps:
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)
125Mbps:
Multi mode: 0 to 2 km/ 5 km, 1310 nm (62.5/125 μm)
Single mode: 0 to 30 km, 1310 nm (62.5/125 μm)
WDM 1.25Gbps:
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
WDM 125Mbps:
Single mode: 0 to 20 km/ 40 km/ 60 km/ 80 km, 1310 nm (9/125 μm); 0 to 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
Protocol CSMA/CD
LED Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red)
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)
DI/DO 2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating Humidity 5% ~ 95% (Non-condensing)
Operating Temperature -20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F(-E model)
Storage Temperature -40°C~85°C / -40°F~185°F
Power Supply 48VDC
PoE Budget 480W for 45~56V input
(55V input is recommended for 802.3at 30W applications)
120W for 802.3af 48V input
PoE pin assignment RJ-45 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W at 54~56VDC/15W at 48V~56VDC.
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.
Power Consumption 10W
Case Dimension Metal case. IP-30,
74 (W) x 135 (D) x 152 (H) mm
Weight 1000 g
Installation DIN Rail and Wall Mount** Design
EMI & EMS FCC Class A,
CE EN61000-6-2, CE EN61000-6-4, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11
Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock),
IEC60068-2-6 (Vibration)
MTBF NA
Warranty 5 years

Software Specifications

Management SNMP v1 v2c, v3/ Web/Telnet/CLI
SNMP MIB RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1643 EtherLike,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
RFC 2790 Host Resource MIB
LLDP MIB*
RSTP MIB*
Private MIB
ITU G.8032 Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)
Support various ring/chain topologies
Includes dynamic coupling ring & aggregation ring*
Enhanced G.8032 ring configuration with ease
Co-exist with RSTP on different ports
PTP v2 Support hardware-based IEEE1588 PTPv2 in 1μs with 4 Dual Speed SFP
PoE Management
  1. PoE Detection to check if PD is hang up then restart the PD
  2. PoE Scheduling to On/OFF PD upon routine time table
Per Port PoE Status On/ Off, voltage, current, watts, temperature
User friendly UI
  1. Auto topology drawing
  2. Topology demo
  3. Auto configuration for G.8032(auto mode) for single ring
  4. DDM threshold monitoring with dB values***
  5. Complete CLI for professional setting
Port Trunk with LACP LACP Port Trunk: 8 Trunk groups/Maximum 16 trunk members
Aggregation ring for ring redundancy and bandwidth combination*
LLDP Supports LLDP to allow switch to advise its identification and capability on the LAN
CDP Cisco Discovery Protocol for topology mapping
Environmental Monitoring** System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models)
VLAN Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP(256 groups)**, QinQ
IPv6/4 Present
Spanning Tree Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree
Quality of Service The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP
Class of Service Support IEEE802.1p class of service, per port provides 8 priority queues
QoS by VLAN Tagged QoS by VLAN for all devices in the network
Login Security Supports IEEE802.1X Authentication/RADIUS
Port Mirror Support 3 mirroring types: “RX, TX and Both packet”
Network Security Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
256 Policy based Access Control List
SSL/ SSH for Management
HTTPS for secure access to the web interface
TACACS+ for Management Authentication*
IGMP Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP**
MVR Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
Bandwidth Control Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.
RTC Built-in Real Time Clock to keep track of time always
Flow Control Supports Flow Control for Full-duplex and Back Pressure for Half-duplex
System Log Supports System log record and remote system log server
SMTP/Text SMS Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile
Relay Alarm Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V
Protection
  1. Miss-wiring avoidance
  2. Repowered auto ring restore
  3. Loop protection
SNMP Trap Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. PoE ping failure
  7. Power failure
  8. Environmental abnormal**
DHCP Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&VLAN based DHCP distribution (DHCP relay agent)
Mac based DHCP Server Assign IP address by Mac that can include dumb switch in DHCP network
DNS Provide DNS client feature and support Primary and Secondary DNS server.
SNTP Supports SNTP to synchronize system clock in Internet
Firmware Update Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
Configuration
upload and download
Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default; USB for auto restore/backup
IfAlias Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface
P/N Model name Description
8350-796 IPES-3416DSFP 16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; 48VDC
8350-797 IPES-3416DSFP-E 16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; -40°C to 75°C; 48VDC
8350-798 IPES-3416DSFP-M 16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; Environmental monitoring; -20°C to 60°C; 48VDC
8350-799 IPES-3416DSFP-M-E 16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; Environmental monitoring; -40°C to 75°C; 48VDC

OPTIONAL ACCESSORIES – 55VDC DIN Rail Power for 802.3at Applications

Model name Description
AD1240-48S-5 48~56VDC, 4.3A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
AD1360-48S-5 48~56VDC, 6.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
AD1500-48S-5 48~56VDC, 9A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)

OPTIONAL ACCESSORIES – Mini GBIC (SFP)

Model name Description Model name Description
8330-162 MINI GBIC 1000SX (LC/0.5km) Transceiver 8330-188 LTSFP-1000BX-10KM Transceiver (WDM 1310)
8330-163 MINI GBIC 1000SX2 (LC/2km) Transceiver 8330-189 LTSFP-1000BX-10KM Transceiver (WDM 1550)
8330-165 MINI GBIC 1000LX (LC/10km) Transceiver 8330-186 LTSFP-1000BX-20KM Transceiver (WDM 1310)
8340-0591 MINI GBIC 1000LHX (LC/40km) Transceiver 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-166 MINI GBIC 1000XD (LC/50km) Transceiver 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-169 MINI GBIC 1000XD (LC/60km) Transceiver 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8330-167 MINI GBIC 1000ZX (LC/80km) Transceiver 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-170 MINI GBIC 1000EZX (120km) Transceiver 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-060 100Base FX 2KM, Multi-mode, LC Transceiver 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-065 100Base FX 5KM, Multi-mode, LC Transceiver 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-061 100Base LX 30KM, Single-mode, LC Transceiver 8330-168 MINI GBIC 1000T (100m) Transceiver

Formations disponibles sur la configuration des switches et les réseaux TCP/IP

IES-2208CA

8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Industrial Managed Switch

  • UL Class I Division II pour les groupes certifiés: A,B,C et D
  • Directive ATEX 94/9/EC certifié (- model ATEX uniquement)
  • « Pro-Ring2se » pour anneaux « self-heal » <20ms
  • Support élaboré SNMP incluant QoS, IGMP query & source uniquement, DDM***, CPU ( charge processeur )
  • Fonction « Factory Default » pour revenir à la configuration de base
  • Certification DNV Type approuvé pour navire , hors bord et plateforme « Off-Shore »
 

 

OVERVIEW

The Lantech IES-2208CA est un switch administrable 8-port 10/100BaseTX + 2-port 10/100/1000T/Dual Speed SFP Combo, avec Pro-Ring2se self-recovery en moin de 20ms. La connexion SFP est disponible pour des vitesses de 100M ou 1000M. Les fonctions avancées SNMP, inclu un QoS à 4 segments , 802.1q VLAN, IGMP snooping, query and source only pour surveillance  Multicast IP, également DDM*** comme fonction « ping » Web, Charge CPU, SNTP et SMTP etc.

 

The Pro-Ring2se self-recovery scheme can recover Ring network in less than 20ms with single ring up to 50 switches with one step setup. Lantech IES-2208CA builds all the important management features required in large network like DHCP Client/Server, 802.1X authentication, IGMP Query / Snooping, and advanced QoS. The exclusive source only function is good for reverse multicast flow which can automatically select the query (router port) in a ring for IP surveillance application. It also supports Ping commands via Web to detect whether a specific device is still connected for easy trouble-shooting.

 

The IES-2208CA has the relay contact that is able to connect with alarm system and send Email and SNMP trap alert in case of power or port failure. It also has the built-in factory reset button can restore all setting back to factory default.

 

The IES-2208CA is designed to meet with critical network environment with IP 30 enclosure and test under extensive Industrial EMI and Safety standards. With UL Class I Division II / ATEX Directive 94/9/EC approval, the IES-2208CA can be implemented in hazardous or explosive condition without accelerating the damage. It’s the best choice for inflammable environment where the liquid, gas and vapor etc might present the hazardous condition which generally to be find in mining, oil & gas, chemical, processing automation areas. It’s also suitable for surveillance, factory automation, transportation, telecom / ISP outside terminal, heavy industrial factory and other factory assembly lines.

 

The -E / -ATEX / DNV model can be used in extreme environments with an operating temperature range of -40°C to 75°C.

 

The Lantech IES-2208CA-DNV meets with the most critical test criteria in DNV Type* test directives consisting of MED (Marine Equipment Directive), EMC (Electromagnetic Compatibility Directive) and LVD (Low Voltage Directive) in which vibration, high voltage, compass safe distance, salt mist tests, humidity etc are conducted to ensure the switch sustaining the harsh on-board environments often founded in Ships, Crafts and Offshore platforms.

FEATURES

  • Pro-Ring2se for self-recovery scheme in less than 20ms for single-ring with one setup
  • SFP slot supports 100/1000 Dual Mode with DDM*** for SFP diagnostic and monitoring
  • Back-plane (Switching Fabric): 5.6Gbps
  • 1Mbits Packet Buffer / 8K MAC address table
  • UL Class I Division II for Group A,B,C and D certified
  • ATEX Directive 94/9/EC certified (-ATEX model)
  • IP30 metal housing with DIN rail and Wall-mount** design
  • Provides EFT protection ±2000 VDC for power line
  • Supports ±6000 VDC for ESD protection
  • Support CPU load monitoring and Web Ping to check if the connected device is alive
  • IEEE 802.1d Spanning Tree & IEEE 802.1w RSTP
  • IGMP with Snooping and Query mode for Multi Media Application
  • IGMP source only for reverse multicast application
  • Static Multicast Route for non-IGMP application
  • Port Based VLAN, 802.1Q Tag VLAN, GVRP
  • Port Trunk with LACP
  • Supports IEEE 802.1ab LLDP
  • Supports IEEE 802.1p CoS, 4 priority queues per port
  • Port base, Tag Base and Type of Service Priority
  • Supports Ingress Packet Filter and Egress Rate Limit
  • Supports Broadcast/Multicast Packet Filter Control
  • Port Mirror: Monitor traffic in switched networks
    • TX, RX, Both of TX and RX Packet
  • System Log Server/Client
  • SMTP e-mail Alert up to 6 emails
  • Security
    • Port Security: MAC address entries/Filter
    • IP Source Guard: IP address security management to prevent unauthorized intruder
    • Login Security: IEEE802.1X/RADIUS;SSH* / SSL*
  • SNMP Trap
    • Device cold start, Power status, Authentication failure, Port Link up/Link down
  • Relay Alarm Output System Events
  • TFTP & Web Firmware Update & System Configure Restore/Backup;
  • Factory reset bottom can restore all setting back to factory default
  • DNV Type Approved* for Ships, Craft and Off-shore Platforms
P/N Model name Description
8350-451 IES-2208CA 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; -20°C to 60°C
8350-452 IES-2208CA-E 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; -40°C to 75°C
8350-451-DLR IES-2208CA-DLR 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; -20°C to 60°C; DLR
8350-452-DLR IES-2208CA-DLR-E 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; -40°C to 75°C; DLR
8350-452-ATEX IES-2208CA-ATEX 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; -40°C to 75°C; ATEX Directive 94/9/EC

OPTIONAL ACCESSORIES – DIN Rail Power

Model name Description
AD1048-24FS 24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)
AD1024-24F 24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)
AD1240-48S 48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
AD1120-48F 48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)

OPTIONAL ACCESSORIES – Mini GBIC (SFP)

Model name Description Model name Description
8330-162 MINI GBIC 1000SX (LC/0.5km) Transceiver 8330-188 LTSFP-1000BX-10KM Transceiver (WDM 1310)
8330-163 MINI GBIC 1000SX2 (LC/2km) Transceiver 8330-189 LTSFP-1000BX-10KM Transceiver (WDM 1550)
8330-165 MINI GBIC 1000LX (LC/10km) Transceiver 8330-186 LTSFP-1000BX-20KM Transceiver (WDM 1310)
8340-0591 MINI GBIC 1000LHX (LC/40km) Transceiver 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-166 MINI GBIC 1000XD (LC/50km) Transceiver 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-169 MINI GBIC 1000XD (LC/60km) Transceiver 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8330-167 MINI GBIC 1000ZX (LC/80km) Transceiver 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-170 MINI GBIC 1000EZX (120km) Transceiver 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-060 100Base FX 2KM, Multi-mode, LC Transceiver 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-065 100Base FX 5KM, Multi-mode, LC Transceiver 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-061 100Base LX 30KM, Single-mode, LC Transceiver 8330-168 MINI GBIC 1000T (100m) Transceiver

All SFP P/N# ended with D are with DDM function