Integration of Siemens S7 Data in IoT Cloud Solutions

S7 DATA IN IOT CLOUD SOLUTIONS

SOFTING INDUSTRIAL ANNOUNCED THAT ITS DATAFEED UAGATE SI GATEWAY NOW ALSO SUPPORTS THE MQTT PROTOCOL IN ADDITION TO OPC-UA, ENABLING EASY AND RELIABLE INTEGRATION OF SIEMENS S7 DATA INTO CLOUD SOLUTIONS.

Thanks to the MQTT protocol’s publisher functionality in the new 1.30 firmware version of its dataFEED uaGate SI, Softing is closing the gap between automation and IT. The gateway to Siemens S7 control systems now also allows easy and secure integration of data into cloud-based IoT and Industrie 4.0 applications. With this move, Softing acknowledges the growing acceptance of MQTT (Message Queue Telemetry Transport) as an IoT standard communication protocol. It is already being natively supported by many respected cloud providers, including Amazon Web Services, IBM Bluemix and Microsoft Azure.

“The dataFEED uaGate SI offers the highest level of security, simple configuration, and low maintenance costs”, says Sebastian Schenk, Product Manager at Softing Industrial. “This new version provides mechanical engineers, system integrators and other customers with a flexible and future-proof tool bridging the interface between industrial networks and IT applications.”

In addition to the MQTT Publisher functionality, the built-in OPC UA Server allows data to be integrated into ERP, MES or SCADA applications. User authentication, certificate handling and SSL encryption ensure maximum security. The gateway is easy to configure via a web browser and supports icon import directly from SIMATIC STEP 7 and TIA Portal projects. dataFEED uaGate SI is equally suitable for new systems and retrofits in existing systems.

The new firmware version 1.30 is available now for download from the Softing website. Existing customers can upgrade to the new version for free. Further information is available here.

ML700 – VDSL2/ADSL2+/ADSL2/ADSL

ML700 – VDSL2/ADSL2+/ADSL2/ADSL

ML700 family delivers high speed Carrier Ethernet services over up to 8 bonded copper pairs utilizing VDSL2/ADSL2+/ADSL2/ADSL technologies. ML700 can support up to 750 Mbps.

All ML700 platforms come in a compact 1RU high by half rack width wide, hardened, fixed form factor that can be flexibly deployed either as an EAD/NTU in a Point-To-Multi-Point scenario, or at both ends of the link in a Point-To-Point scenario.ML700 link rate and reach can be extended using Actelis’ BBA* Broadband Amplifiers(VBA or ABA).

The ML700 offer MEF compliant services, 802.1q VLAN-aware wire-speed bridging, double tagging (VLAN stacking), advanced provisioning using Ethernet Virtual Connections (EVCs), L2, L3 and L4 classification with flexible mapping into eight traffic classes to maximize the efficiency of access bandwidth.

ML700 can be deployed within Actelis’ compact enclosures offering integrated remote or local power modules for ease of installation.

ML700 EADs offer the highest link resilience and best-in-class customer Quality of Experience (QoE) through its unique implementation of SRA (Seamless Rate Adaptation) and Impulse Noise Protection (INP) mechanisms in accordance with G.inp for unsurpassed bonded-link reliability.

The ML700 EADs provide proactive and dynamic tools for enhanced trouble shooting and monitoring capabilities. Advanced Carrier-class EFM OAM, including 802.3ah, CFM (802.1ag) and Y.1731 (ITU), are incorporated, offering both physical link as well as service level end-to-end advanced troubleshooting mechanisms.

The ML700 EADs can be managed In and Out-of-Band by the Actelis’ MetaASSIST™ View and via the multi-platform Element Management SystemMetaASSIST EMS. The management protocols include standard command line interface and SNMP using standard MIBs for seamless integration with third-party Network Management Systems (NMS).

OPC UA C++ Developpement Toolkit pour Linux

OPC UA C++ : Outil de Développement pour environnement Linux

Developpement rapide des OPC UA Serveurs et Clients pour Linux en C++

L’OPC UA C++ Development Toolkit permet une intégration facile et rapide des capacités de connectivité OPC Unified Architecture (UA) dans les applications d’automatisation basée sous Linux. Il se compose d’un ensemble de bibliothèques, doté d’une interface de programmation simple et documentée. Les exemples d’applications, ainsi que les outils de test et de simulation, permettent une mise en service  rapide de vos applications OPC UA.

Interface d’intégration facile à utiliser  – “Time-to-Market” “Retour sur investissement” rapide

  • Développement des Clients et des serveurs OPC UA pour l’intégration des interfaces OPC UA, sur matériel basé sur Linux
  • Interface de programmation Optimisée (API) et facile à dans la compréhension de son utilisation
  • Exemples d’applications , tutorial , test complexe et simulation de clients et serveurs.  pour une mise en router de vos applications
  • Utilisable dans pour des taches critique de controle, ainsi que pour de projets d’automatisme complexes

Performance éprouvé sur le marché leader

  • Accès à plus de 15 années d’expertise dans le domaine du développement OPC
  • Technologie elle même, incorporée dans les produits “Middleware”
  • Système de développement fiable, qui permet la mise en oeuvre d’échange de données depuis un système de production à la gestion de l’entreprise.

Solution complète pour toutes les demandes de clients

  • Ensemble de blocs de construction offrant  des fonctionnalités requises pour implémenter des Clients et des serveurs OPC UA
  • Fonctionnalités étendues, comprenant la sécurité étendue, l’accès aux données, données complexes, concours complet et “accès historique” en C++ pour Linux
  • Concepts de sécurité intégrée, permettant à des données distantes et sécurisées, des  transferts actives, face aux menaces de sécurité moderne

Coup réduit de la téchnologie (Developpement, Maintenance)

  • OPC – pret à l’emploi – en accord avec les spécifications OPC
  • Economisant jusqu’à 2 ans d’effort de développement et réduit le temps de mise sur le marché de votre application
  • Rapididé de mise en conformité à la norme OPC
OPC Specifications Unified Architecture V1.04
OPC Roles OPC UA Client, OPC UA Server
OPC UA Client Profiles Core Characteristics, Data Access, Complex Data, Base Eventing, Methods, Audit, Historical Access, Alarms and Conditions, Query, Redundancy, Publisher, Subscriber
OPC UA Server Profiles Core Characteristics, Data Access, Complex Data, Base Eventing, Methods, Audit, Historical Access, Alarms and Conditions, Publisher, Subscriber
OPC UA Transport OPC UA TCP transport; UA Binary Encoding, UA Secure Conversation
HTTPS transport; UA Binary Encoding
UADP Publisher, UADP Subscriber
OPC UA Security Security policy: Aes128Sha256RsaOaep, Aes256Sha256RsaPss, Basic256Sha256/Basic256/Basic128Rsa15/None
Authentification: anonymous/user name and password/user certificate
Full compliance to OPC UA 1.04 specification
Programming Interface* C++
Development Environment* GCC (Version 4, 5, 6, 7)
Development Operating Systems* Any Linux system
(tested on Ubuntu 14, 16, 18)
Any Linux system
(The binary delivery includes: Linux PC platforms on Intel 32 and 64 Bit processors, ARMv6, 32 Bit)
Compliance/Certification OPC Foundation certification for Server, regularly tested at OPC Foundation interoperability workshops
Support Tools Comprehensive programming examples and tutorials, complex test and simulation OPC UA Server and Client applications, generic technology test and demonstration Client and Server tools
Trial Version Trial toolkit assemblies contain complete functionality. Limitation to 90-minute runtime period applies.
Trial version upgrades to unlimited functionality simply by using binary license activation key.
Licensing Trial and evaluation license, single seat developer license (binary and source code version)
Applications integrating licensed dataFEED OPC UA SDK libraries can be deployed in unlimited number of copies.

*Binary support for embedded systems is available on request and usually accompanied by a small integration project.
Please contact the Softing sales representative for requests of different compilers or operating system variants.
Known to work on several Linux distributions as well as on Solaris and QNX,, expected to be easily ported to other Unix-based platforms.

  • Data Sheets

  • Drivers & Software

    • OPC UA Demo Client Package (Free of Charge, Unlimited Runtime)
    • OPC UA Demo Server Package (Free of Charge, Unlimited Runtime)
  • Manuals & Documentation:

  • Articles & White Papers

  • Certificates

LMA-DD-035131 Service and Support Contract for OPC UA C++ Client Toolkit for Linux, Binary Format, Minimum Duration 3 Years, Includes WRL-DD-035131, single seat developer license
WRL-DD-035131 OPC UA C++ Client Toolkit for Linux, Single Seat Developer License, Binary Format. Available only in combination with LMA-DD-035131
LMA-DD-035132 Service and Support Contract for OPC UA C++ Server Toolkit for Linux, Binary Format, Minimum Duration 3 Years, Includes WRL-DD-035132 license
WRL-DD-035132 OPC UA C++ Server Toolkit for Linux, Single Seat Developer License, Binary Format. Available only in combination with LMA-DD-035132
LMA-DD-035231 Service and Support Contract for OPC UA C++ Client Toolkit for Linux, Source Format, Minimum Duration 3 Years, Includes WQL-DD-035231 license
WQL-DD-035231 OPC UA C++ Client Toolkit for Linux, Single Seat Developer License, Source Format. Available only in combination with LMA-DD-035231
LMA-DD-035232 Service and Support Contract for OPC UA C++ Server Toolkit for Linux, Source Format, Minimum Duration 3 Years, Includes WQL-DD-035232 license
WQL-DD-035232 OPC UA C++ Server Toolkit for Linux, Single Seat Developer License, Source Format, Available only in combination with LMA-DD-035232
LEA-DD-030300 Site License extension for OPC Development Toolkits

Scope of Delivery

Software Installation package on Softing OPC Toolkits DVD-ROM, installation package available for download
Support Dedicated Support Team
Documentation Reference Manual in English in CHM format as part of the installation package

Additional Products and Services

OPC-ENTW-TAG OPC Engineering / Consulting / Compliance Assistance
TRA-OPC-UA OPC UA Introductory Training for decision makers and technical leaders
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, OPC UA support, access of any number of OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and dataFEED OPC Tunnel Servers plus additional functionality like Database Access, File Access, Data Exchange, Optimizer, Concentrator and Bridge

From OPC Data Access to OPC Unified Architecture

The latest edition of the OPC Book provides an excellent overview of the fundamentals, implementation and application of standardized data exchange via OPC. A key focus is on the new OPC generation – OPC Unified Architecture – that allows for platform-independent data and information exchange.

  • Comprehensive Overview of OPC
  • Detailed Introduction to OPC UA
  • Tools and Demo Programs
Order the Book: From Data Access to Unified Architecture

Comprehensive Overview of Specifications and applications

The OPC Book provides an introduction to all OPC Specifications released by the OPC Foundation, from the very first to the most recent. OPC stands for Openness, Productivity and Collaboration, symbolizing the new possibilities opening up in automation technology. In addition to the fundamentals of OPC, the book discusses the implementation of OPC servers and clients, and presents application possibilities and examples. This gives readers a comprehensive overview of OPC technology and application areas.

The New OPC Generation – OPC Unified Architecture

A key focus of the book is on the OPC Unified Architecture (OPC UA). The new OPC generation allows service oriented, multivendor, and cross-platform capable data and information exchange. Among the most important subjects here are the specifications of this Windows-independent technology, the OPC UA application possibilities, the development of OPC UA products for Windows, Linux and VxWorks operating systems, and the migration from OPC Classic to OPC UA. The book provides a solid foundation of knowledge for readers to build and use products supporting OPC UA in automation.

Tools and Demo Programs on CD-ROM

The included CD-ROM contains demo versions of a variety of OPC servers and OPC tools. It also provides several demonstration programs for development, commissioning, testing, and for the simulation of OPC clients and servers. Another major part of the CD-ROM is dedicated to OPC UA introductory videos and presentations. The comprehensive content makes it easy for readers to get started with OPC Classic and OPC UA.

 

Contents

  • Introduction
  • Fundamentals – Classic OPC Specifications, OPC Unified Architecture, Companion Standards, OPC Compliance Testing
  • Implementation – Base Technologies and Architecture Concepts, Implementation of Classic OPC Components, Implementation of OPC UA Components
  • Application – Classic OPC Product and Application Samples, Aspects of Use of Classic OPC Products, OPC UA Product, Samples, Performance

Summary and Outlook

Scope of Delivery

OPC Book with CD-ROM

 

 

CAN-AC2-PCI

CAN-AC2-PCI

Carte Universelle PCI avec micro contrôleur

Interface CAN simple ou double canaux, au format PCI pour réseaux CAN et CANopen

Interface fléxible pour PC embarqués et industriels

  • Data exchange between PC applications and connected CAN bus
  • Available in single and dual channel versions
  • Universal solution matching almost any CAN application
  • Use, for instance, in machine controllers, PC-based applications, test rigs or real-time simulations
  • Integration in Mathworks xPC Target

Rapid Integration with right Software Interface

  • Flexible API including FIFO storage buffering all sent and received messages, separately for each channel
  • No data loss when computer working on other tasks
  • Filtering and buffering of messages of interest
  • Automatic transmission of data to bus in exact, individually configurable cycles
  • Free CANopen Client API available for use in CANopen networks

Application in a Wide Variety of Target Systems

  • Use in Windows operating systems
  • Linux driver
  • Sample projects for C, C# or VB.NET with commented source code
Single Channel Dual Channel
CAN Protocol and Available APIs
CAN V2.0 (11/29 Bit IDs)
CAN API
CANopen Client AP
CAN Bus Connection
Connector 9-pin D-sub male
No. of Channels 1 2
Galvanically Isolated
Physical Layer ISO 11898-2 (CAN High Speed)
PC Interface PCI Rev. 2.1, 4 KB DPRAM
Interrupts Plug-and-play
Operating Temperature 0 °C … +70 °C
Storage Temperature -20 °C … +70 °C
Relative Humidity < 90%, non-condensing
Dimensions 160 mm x 100 mm
Power supply
Supply voltage 5 VDC (±5 %)
Current consumption Typically 380 mA Typically 410 mA
Drivers available for Windows XP, Windows 7, Windows 8, Windows 10, Linux
Conformity
CAN-AC1-PCI Single Channel
CAN-AC2-PCI Dual Channel

Scope of Delivery

Hardware PC interface board
Software Drivers, APIs, sample programs on CD-ROM
Documentation On CD-ROM

CAN and CANopen have a permanent place in the industrial environment. The reliability and robustness are important aspects for optimal operation. Efficient failure analysis and fast troubleshooting contribute to the high availability in networks.

During our training you learn everything from A to Z on CAN and CANopen for daily practice. We teach you the necessary specific knowledge to plan, operate and maintain CAN networks.

The CAN-AC2-PCI has no ITAR  classification

The CAN-AC2-PCI has no ECCN  classification

Routeur BACnet

Routeur BACnet

Le Routeur BACnet (FS-routeur-BAC) de Sierra Monitor, offre une solution complete BACnet, pour les interconnexions de réseaux BACnet/IP, BACnet Ethernet et réseaux BACnet MS/TP, tout en assurant une connexion sécurisée

Connexions multiples BACnet peuvent être établies:

  • BACnet MS/TP vers BACnet/IP
  • BACnet MS/TP vers BACnet Ethernet
  • BACnet MS/TP vers BACnet MS/TP
  • BACnet/IP vers BACnet/IP
  • BACnet/IP vers BACnet Ethernet

Le routeur  FieldServer BACnet est disponible en 2 modèles : une verion “dual-port” et une  version “single-port”.

Acceder au routeur BACNet via FieldPoP

Profitez du Cloud,grâce a Fieldpop.  The routeur BACnet peut utiliser Filedpop. Ce qui signifie que tous les routeurs BACnet, peuvent s’enregistrer  sur le cloud Sierra Monitor, Filedpop pour le IIoT.

L’interface FieldPoP, permet au utilisateurs, d’accéder a distance aux routeurs, de façon sécurisée. la FS-GUI et les applications web, sont disponibles locallement sur le routeur BACnet. Ces applications offre la possibilité de configurer, monitoring, logging, sécurité, diagnostic et mise a jour.

Learn more about FieldServer and FieldPoP capabilities »

Des fonctionnalités innovantes

Le routeur possède 2 ports, RS-485 et permet de connecter jusqu’à 64 devices BACnet, sans utiliser de drivers additionel.The dual-port BACnet Router has two RS-485 ports, enabling connection to up to 64 BACnet devices without the use of additional line drivers. Using a BACnet router frees up valuable RS-485 ports on expensive BACnet Controllers and reduces the cost of connecting BACnet MS/TP devices to a BACnet/IP backbone. Compared to single-port BACnet routers, our dual-port BACnet router can reduce the cost of device connectivity or double the speed of connected devices (half the response time).

Ce routeur, d’entrée de gamme est à un prix très attractif solution BACnet. Il possède un port RS 485 et peux se connecter jusqu’à 32 devices BACnet, sans drivers additionnels.

DeviceFind™,  notre fonctionalité unique, permet l’intégration de tous les device BACnet connecté au routeur, par une simple pression d’un bouton sur le routeur, ce qui permet un gain de temps non négligeable. En complément à cette fonction, notre toolbox pour diagnostic, permet de faire un état du réseau, via le routeur.

Installation facile et rapide

Notre page de configuration, sur le routeur BACnet, se fait facilement. L’interface dispose d’une capacité de “Network discovery” et minimize le temps d’installation. La pile BACnet certifiée, permet d’éviter le temps de débug. Un modle MDIX, permet l’utilisation de n’importe quel cable Ethernet pour l’installation et le debug. Le DHCP permet d’obtenir une adresse IP automatiquement.

Le routeur BACnet inclu la fonction NAT avec un deuxieme connection  BACnet/IP. Il permet ainsi, de “router” des IP privées avec des adresses IP publiques. le “BACnet Broadcast Management Device (BBMD)” permet  la connexion entre différents ‘subnets’ La configuration ‘Web-based’ rend la configuration plus que facile.

Certifications & approbations

Les routeurs Sierra Monuitor sont les premiers appareils pour le domaine industriel, afin de porter la marque BTL La certification assure le standard de l’int”gration BACNet et assure l’utilisateur, d’utiliser un produit BACnet de qualité. le logo BTL indique que le routeur a passé des tests rigoureux en laboratoire et que le produit dispose des possibilités / qualités BACnet. De plus, nos routeurs sont certifiés :RoHS, Approuvé TUV jusqu’à UL-916, et CSA, CE et FCC approved.

RUT-955

LTE ( 4G ) ( Download jusqu’à : 100Mbps / Upload jusqu’à : 50Mbps) Routeur avec double carte SIM, avec wifi et 4 ports Ethernet, I/O, RS232, RS485 et GPS

RUT955 : hautement sécurisé et performant, ce routeur LTE possède des sorties I/O, GPS et RS232/RS485 pour applications professionnelles.

Ce routeur délivre de hautes performances, pour des missions de communication critiques et localisation GPS. Le RUT-955 est équipé de systemes de connectivité redondant, via double carte SIM.  Antennes externes de type SMA, permet d’utiliser le type d’Antennes souahité.

RUT955 Schema

TECHNOLOGY HARDWARE FIRMWARE
LAN RS232 i Remote configuration over SMS
4G (LTE) – Up to 100 Mbps i RS485 i Bridge mode
3G – Up to 42 Mbps i Micro SD i Automatic and manual operator selection
GNSS i 2x SIM Card (Dual-SIM) i Static routes i
WiFi – Up to 300 Mbps i 3x LAN 10/100Mbps Ethernet ports i PPPoE
GPRS i 1x WAN 10/100Mbps Ethernet ports i NTP i
SMS i IEEE 802.11b/g/n WiFi standards i Wireless Hotspot
  Durable aluminum housing i Wireless Client
  0 – 3V digital input i Wireless AP
  0 – 30V digital galvanically isolated input i Ping reboot i
  0 – 24V analog input i Periodic reboot i
  30V, 250mA digital open collector output i Real-time graphs
  40V, 4A SPST relay output i Backup WAN i
  USB A socket for external devices i Mobile Traffic counter
  2 pin industrial DC power socket i Connection status overview bar
  Power over Ethernet (not compliant with IEEE 802.3af – 2003) i Configuration backup/restore
  I/O connector VRRP
  Mobile antenna type – 2 x SMA IPsec
  WiFi antenna type – 2 x RP-SMA GRE Tunnel
  GNNS antenna type – 1 x SMA OpenVPN
  Input voltage range – 9-30 VDC PPTP i
  Operating temperature range – -40°C to 75° C L2TP i
  Storage temperature range – -45ºC to 80º C SNMP i
  Power consumption – < 7W SNMP Trap i
  Mounting options – DIN Rail, Wall Send/receive SMS
  LED indication – 1x bi-color connection status, 5x connection strength, 4x LAN status, 1x Power Status via SMS i
  SMS reboot i
  3G/4G enable/disable via SMS i
  Wireless on/off via SMS i
  OpenVPN on/off via SMS i
  Web Filter i
  Mobile on Demand i
  Mobile Data Limit i
  Configuration Profiles i
  Event logging i
  QoS i
  Restore Point i
  Call Utilities i
  SIM switch i
  FOTA (Firmware Over The Air) i
  Event reporting (via Email/SMS) i
  Integrated speed test i
  Network Scanner with Topology display i
  Disable Roaming i
  SMS gateway i
  OSPF i
  Access control safety i
  SIM Idle protection i
  VLAN i
  CLI i
  Firewall i
  IP/MAC filter i
  TR-069 i
  DHCP server i
  Dynamic DNS i
  RMS support
 

  • LTE up to 150 Mbps DL and 50 Mbps UL
  • DC-HSPA+ up to 42 Mbps DL and 5.73 Mbps UL
  • Multiple LTE FDD bands
  • IEEE 802.11b/g/n WiFi with 2×2 MIMO up to 300 Mbps
  • OpenVPN, PPTP, L2TP, IPsec, VRRP, GRE Tunnel
  • SMS Control, WiFi Hotspot, Mobile on Demand, Backup WAN
  • Input Triggers, Samba Share, GPS
  • Four Ethernet ports
  • 3 x input, 2 x output ports
  • MicroSD card slot
  • 4 pin industrial socket for 2/4 wire RS485
  • DB9 socket for full-featured RS232
  • USB type-A socket for external devices
  • Durable aluminum housing
  • External antennas
  • Dual SIM
  • Dual FW image

Reférence :

  • RUT-955-H ( Europe )
  • RUT-955-J ( USA /Canada )

Training on demand

FM1100

FM1100 – GPS Tracker sans battery interne

Un tout petit appareil avec des capacités incroyables. Le FM1100 est l’appareil idéal pour vos applications de tracking

FM1100 – Système GPS Tracking, sans antenne et sans batterie

  • Petite Taille
  • Car tracking
  • Opération de paramétrisation (acquire & send)
  • scenaries intégrés
    • Dépassement de vitesse
    • Conduite autorisée  (50 iButton keys)
    • Immobilisateur
  • Tracking à la volée
  • Faible consommation d’énergie en mode “sommeil”
  • Supporte les fonctionlaités LV-CAN200, ALL-CAN300
  • 1-wire (driver ID or temperature monitoring; RFID (Mifare) support)

TECHNOLOGY HARDWARE FIRMWARE
GNSS i External GSM antenna  LV-CAN support
GPRS i External GNSS antenna  ALL-CAN support
SMS i DIN – digital input – 3  Ignition detection
AIN – analog input – 1 Geo-fence
DOUT Sleep/Deep sleep i
1-Wire® – 1 Overspeeding detection i
Accelerometer FOTA i
IP41 Remote Log i
16MB memory GPRS commands i
10 – 30V  RFID 1-Wire® i
Overvoltage protection iButton 1-Wire® i
1x SIM Card Temp. 1-Wire® i
USB 2.0 Interface Immobilizer i
Green driving i
Jamming detection i
NTP time synch. i
SMS event i
Odometer i
Trip detection i
Integrated scenarios i
Remote configuration over SMS i
Offline tracking i
Auto Geofencing i

GSM:

  • Quad-band 900/1800 MHz; 850/1900 MHz
  • GPRS class 10 (up to 85,6 kbps);
  • SMS (text/data)

GPS/GLONASS:

  • NMEA protocol compatible. Messages: GGA, GGL, GSA, GSV, RMC, VTG, TXT
  • 32 channel GPS/GLONASS receiver
  • -161 dBm sensitivity

Interface:

  • 1 Digital Input Reserved for Ignition Status Monitoring
  • 2 Digital Inputs
  • 1 Analog Input (10V or 30V range)
  • 2 Digital Open-collector Outputs (connecting external relays, LED, buzzers etc.)
  • 1-Wire® protocol
  • Power supply (+10…+30) V DC
  • 2 Status LEDs
  • USB Port
  • Configuration and firmware upload (FOTA and via USB cable)
  • External GSM antenna (SMA connector)
  • External GPS/GLONASS antenna (MCX connector)

Features:

  • GPS/GLONASS and I/O data acquisition
  • Real Time tracking
  • Smart algorithm of data acquisition (time, distance, angle, ignition and event based)
  • Sending acquired data via GPRS (TCP/IP and UDP/IP protocols)
  • Smart algorithm of GPRS connections (GPRS traffic saving)
  • Operating in roaming networks (preferred GSM providers list)
  • Events on I/O detection and sending via GPRS or SMS.
  • Scheduled 24 coordinates SMS sending
  • 5 geofence zones (rectangular or circle)
  • Deep Sleep mode (saving vehicle’s accumulator)
  • FOTA (firmware updating via GPRS)
  • Motion sensor
  • Small and easy to mount case
  • Roaming dependant operation (GPRS traffic saving in roaming zones)
  • Operation mode presets:
    • Advanced overspeeding detection
    • Driver identification (1-Wire® iButton ID key)

Reference : FM1100

Téléchargement

User manual

[ TELTONIKA ] Antenne déportée 3G/4G

Antenne déportée 3G/4G – Longueur de cable 3.00m

3G/4G Remote antenna

Antenne déportée 3G/4G

  • Connecteur SMA
  • Longueur de cable: 3.00 m
  • Base magnétique
  • 5 dBi

( Ref : ANTENNA-GSM-1 )

SMA Connecteur

People also viewed :

RUT-900

Catégories 3G, 4G

IPGS-0204DSFP

IPGS-0204DSFP

4 10/100/1000T PoE at + 2 Dual Speed SFP Industrial Unmanaged Switch

IPGS-0204DSFP

4 10/100/1000T PoE at + 2 Dual Speed SFP switch Industrial “non administrable”

  • Conformes aux directives du standard IEEE 802.3at/af PoE
  • Alimentation redondante
  • “Booster” d’alimentation de 12V à 48V DC
  • Temperature d’utilisation de  -40°C à 75°C

Le switch IGS-0204DSFP est un  4* 10/100/1000T + 2 Dual Speed SFP Switch Industriel.  Ce switch extra plat, peut se fixer sur un mur ou via DIN rail, faisant de ce switch facile a flexible

Le switch IGS-0204DSFP a été conçu our répondre aux exigences industriels les plus strictes. Avec un boitier  IP30, il rempli toutes les exigences industriels standard EMI EMC. Mécanique testée contre les choques et vibration. Ce switch support des températures d’utilisation de  -40°C to 75°C.

  • DIP switch to adjust SFP 100M or 1000M speed
  • Back-plane (Switching Fabric): 12Gbps
  • Supports wide operating temperature (-40°C~75°C)
  • Redundant power with polarity reverse protection
  • IP-30 protection with DIN Rail and Wall Mount design
  • Relay output for power fail and alarm

Hardware Specifications

Switch Architecture Back-plane (Switching Fabric): 12Gbps
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet port
Packet Buffer 1Mbits
Mac Address 8K MAC address table
Connector 10/100/1000T: 4 x RJ-45
Mini-GBIC: 2 x 100/1000 Dual Speed SFP Sockets
DIP Switch SFP Speed 1000M or 100M
Protocol CSMA/CD
LED Per unit: Power 1 (Green), Power 2 (Green), Fault (Red)
4 port 10/100/1000T: Link/Activity (Green), Full duplex/Collision (Yellow)
SFP port: LNK/ACT(Green)
Power Supply Dual DC 9.5V~56V
Operating Humidity 5% to 95% (Non-condensing)
Operating Temperature -40°C ~ 75°C
Storage Temperature -40°C ~ 85°C
Case Dimension IP30, 43mm (W) x 152mm (H) x 105mm (D)
Installation DIN rail or Wall mounting design
EMC/EMI FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT),
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8, CE EN55022 Class A, CE EN55024
Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration)
MTBF 1,890,546 hrs
Warranty 5 years

Accessoires Optionnels – Mini GBIC (SFP)

Nom et description
8330-162X MINI GBIC 1000SX (LC/0.5KM) Transceiver 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-163X MINI GBIC 1000SX2 (LC/2KM) Transceiver 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-165X MINI GBIC 1000LX (LC/10KM) Transceiver 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8340-0591 MINI GBIC 1000LHX (LC/40KM) Transceiver 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-166 MINI GBIC 1000XD (LC/50KM) Transceiver 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-169 MINI GBIC 1000XD (LC/60KM) Transceiver 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-167 MINI GBIC 1000ZX (LC/80KM) Transceiver 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-170 MINI GBIC 1000EZX (120KM) Transceiver 8330-071 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver
8330-168 MINI GBIC 10/100/1000T (100m) Transceiver 8330-072 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver
8330-060 100Base FX 2KM, Multi-mode, LC Transceiver 8330-069 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver
8330-065 100Base FX 5KM, Multi-mode, LC Transceiver 8330-068 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver
8330-061 100Base LX 30KM, Single-mode, LC Transceiver 8330-080 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver
8330-197 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) 8330-082 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver
8330-198 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) 8330-081 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-195 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) 8330-083 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver
8330-196 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) 8330-084 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver
8330-188 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) 8330-085 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver
8330-189 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) 8330-191 Dual Speed SFP 100M/1000M-LX 10KM Transceiver
8330-186 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310)

 

IPES IES 5416T

16 10/100TX + 4 10/100/1000T X-coded L2+ 8 PoE at/af Industrial Managed Switch w/ enhanced G.8032 Ring & PTP

  • Support PTPv2 two-step transparent clock @ 4 10/100/1000T ports
  • EN50155/61373/45545-2 verification
  • IEEE802.3at/af up to 30W per port; PoE management incl. detection and scheduling
  • Optional 12V input boost to 54V output for IEEE802.3at/af max.80W
  • Optional 72V input steps down to 48V output for IEEE 802.3at/af max.80W
  • Optional 110V input to 48V output for IEEE 802.3at/af max.80W
  • Enhanced G.8032 ring protection < 20ms with auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP
  • Relay contact & environmental monitoring
  • Miss-wiring avoidance; Repowered auto ring restore (node failure protection)
  • IP67/IP54 housing; User friendly UI, including auto topology drawing; Complete CLI
  • N-key configurator** for upgrading, auto/editable configuration back up and restoration without computer
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port&VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3, IPv6, SMS
OVERVIEW
Lantech IPES-5416T-8-X (IP67/IP54) is a high performance L2+ (Gigabit uplink) switch with 16 10/100TX(d-coded) + 4 10/100/1000T(x-coded) w/8 PoE 802.3af/at Injectors by M12 provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including train coupling ring , and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.
Lantech IPES-5416T-8-X (IP67/IP54) features hardware-based PTP IEEE1588 v2 two-step function which can allow 4 10/100/1000T uplinks to synchronize the network with precise accuracy.
Lantech IPES-5416T-8-X (IP67/IP54) supports IEEE802.3at/af standard which can feed HI-power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, High power wireless AP etc. The advanced PoE management includes PoE detection and scheduling besides the regular PoE per port status. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status can remotely On/Off the power and display information of voltage, current, watt and PoE temperature.
The Lantech IPES-5416T-8-X (IP67/IP54) series is designed with various dual power input at 12/24/48VDC input (12V model), 72V input to feed 48V PoE (72V model). The 110V model can accept dual 110V to feed 48V POE and feed PoE power 48V at PoE budget max 80W. Featured with relay contact alarm function, the IPES-5416T-8-X (IP67/IP54) is able to connect with alarm system in case of power failure or port disconnection events. The IPES-5416T-8-X (IP67/IP54) also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
The IPES-5416T-8-X (IP67/IP54) also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5416T-8-X (IP67/IP54) is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 and relay agent function (port&vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.
Lantech InstaConfig software** provides easy configuration for mass deployment. The configuration file can also be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The built-in watchdog design can automatically reboot the switch when cpu is found dead.
The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5416T-8-X (IP67/IP54) much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The complete CLI enables professional engineer to configure setting by command line.
Lantech IPES-5416T-8-X (IP67/IP54) features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 16 MSTI. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.
The configuration file of Lantech IPES-5416T-8-X (IP67/IP54) can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The optional N-key configurator offers firmware upgrade, auto/editable configuration back up and restoration without computer by adjusting the DIP switch.
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
In case of event alarm, the IPES-5416T-8-X (IP67/IP54) will immediately send an email & SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 1DI and 1DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
The built-in environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.
The IPES-5416T-8-X (IP67/IP54) is designed to meet with critical network environment with IP67/IP54 aluminum enclosure and M12 connectors for water proof. It passed serious tests under extensive Industrial EMI and Safety standards. With EN45545-2 Fire & Smoke, and EN50155 verification, the IPES-5416T-8-X (IP67/IP54) is best for railway and vehicle applications. For more usage flexibilities, IPES-5416T-8-X (IP67/IP54) supports wide operating temperature from -40°C to 75°C.
The optional bypass relay is set to bypass the switch to the next one in 4ms when power is off in order to protect the network from crashing. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. The bypass is also activated when detecting the CPU watchdog is ON.
FEATURES
  • 16 10/100TX d-coded + 4 10/100/1000T x-coded w/8 PoE 802.3af/at Injectors Industrial Managed IP67 M12 Switch (Total 20 Ports Switch)
  • EN45545-2 Fire & Smoke, EN50155 and EN61373 shock/vibration verification
  • IEEE802.3at/af feeding power up to 30W per PoE port at 45~56VDC at port 1-8
  • PoE management including PoE detection and scheduling for PD (power devices)
  • 12V model can accept dual 12V power input and boost to 54V for PoE 802.3at/af max 80W budget
  • 72V model can accept dual 50.4~90V power input and feed 48V for PoE at/af at max 80W budget
  • 110V model can accept dual 43V~137.5V inputs and feed 48V for PoE at/af at max 80W budget
  • IEEE 1588 PTP v2 two-step at 4 Giga ports
  • Back-plane (Switching Fabric): 11.2Gbps
  • 16K MAC address table
  • 10KB Jumbo frame supported on all ports
  • User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
  • Enhanced G.8032 Ring protection in 20ms < 256 switches
    • Support various ring/chain topologies, including train dynamic coupling ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Co-exist with RSTP on different ports
  • Provides EFT protection ±2000 VDC for power line.
  • Supports ±6000 VDC Ethernet ESD protection
  • LACP load balancing to distribute the load*
  • Built-in RTC (Real Time Clock) to keep track of time
  • Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority
  • IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy
  • 4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*
  • Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server for Port&Vlan based DHCP distribution
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress packet filter and egress rate limit
    • Broadcast/multicast packet filter control
  • Relay alarm output system events
  • Miss-wiring avoidance
    • LED indicator
    • Email, traps, or SMS notification
  • Repowered auto ring restore
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
  • System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • Management access control with priority
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
  • Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow
  • Multicast VLAN registration* for metro video
  • IGMPv1,v2,v3 with Query mode for multi media; GMRP**
  • N-key** configurator for firmware upgrade, auto/editable configuration back up and restoration
  • Watchdog design to auto reboot switch CPU is found dead
  • Built-in environmental monitoring for system input voltage, current, ambient temperature
  • Supports DIDO (Digital Input/Digital Output)
  • IP67 aluminum housing with wall mount and DIN rail** design; IP54 aluminum housing with wall mount design
  • Bypass protection** – Bypass failed switch caused by power failure of switch to protect network intactness

With Bypass Protection

P/N Model name Description
8361-6179 IPES-5416T-8-X-67-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection
8361-6049 IPES-5416T-8-X-67-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection
8361-6189 IPES-5416T-8-X-67-12V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6059 IPES-5416T-8-X-67-12V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6159 IPES-5416T-8-X-67-72V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
w/ 1 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6069 IPES-5416T-8-X-67-72V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
w/ 2 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6178 IPES-5416T-8-X-54-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection
8361-6048 IPES-5416T-8-X-54-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection
8361-6188 IPES-5416T-8-X-54-12V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 1 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6058 IPES-5416T-8-X-54-12V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
w/ 2 pair GigaT bypass protection; 12V~48V dual input; 80W@12V; 120W@24V
8361-6158 IPES-5416T-8-X-54-72V-B 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
w/ 1 pair GigaT bypass protection; 50.4~90V dual input 80W PoE
8361-6068 IPES-5416T-8-X-54-72V-BB 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
w/ 2 pair GigaT bypass protection; 50.4~90V dual input 80W PoE

Without Bypass Protection

P/N Model name Description
8360-6179 IPES-5416T-8-X-67 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C
8360-6189 IPES-5416T-8-X-67-12V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
12V~48V dual input; 80W@12V; 120W@24V
8360-6159 IPES-5416T-8-X-67-72V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 60°C;
50.4~90V dual input 80W PoE
8360-7379 IPES-5416T-8-X-67-110V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP67 Switch; -40°C to 75°C;
43~137.5V dual input 80W PoE
8360-6178 IPES-5416T-8-X-54 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C
8360-6188 IPES-5416T-8-X-54-12V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
12V~48V dual input; 80W@12V; 120W@24V
8360-6158 IPES-5416T-8-X-54-72V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 60°C;
50.4~90V dual input 80W PoE
8360-7378 IPES-5416T-8-X-54-110V 16 10/100TX 8 PoE at/af up to 30W + 4 Giga T PTP L2+ Managed Industrial PoE M12 IP54 Switch; -40°C to 75°C;
43~137.5V dual input 80W PoE

Optional accessories

odel name Description
ECONM23-5P(F)70CM CABLE M23 power cable 90 degree angle, 70cm, 5 pin, Made in Taiwan
ECONM23-5P(F)70CM CABLE-C M23 power cable 90 degree angle, 70cm, 5 pin, Made in China
ECAB124030MJS 4 Pin M12 RJ45 Male 3 Meters; STP Cable
ECABM12X83MSTP 8 Pin M12 X-coded RJ45 Male 3 METER, STP CABLE w/ Shielding

Training on demand available

SPECIFICATIONS

Hardware Specifications

Standards IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
Switch Architecture Back-plane (Switching Fabric): 11.2Gbps
Transfer Rate 14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port
CPU Marvell 800Mhz
RAM 256M Byte
Flash 128M Byte
Mac Address 16K MAC address table
Jumbo frame 10KB on all ports
Connectors 10/100TX: 16 x ports M12 4-pole D-coded with Auto MDI/MDI-X function
10/100/1000T: 4 x ports M12 8-pole X-coded with Auto MDI/MDI-X function
RS-232 connector: 1 x M12 5-pole A-coded
Power Input connector : 1 x M23 5-pole A-coded
Relay contact : 1 x M12 5-pole A-coded
Network Cable 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
Bypass Protection** High-speed optical switching (<4ms)
Minimal insertion loss (Max 1.6dB as Bypass Mode)
Protocol CSMA/CD
LED Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), RM (Green)
Ethernet port: Link/Activity (Green), Speed (Green); Optical fiber: Link/Activity (Green)
DI/DO 1 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
1 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating Humidity 5% ~ 95% (Non-condensing)
Operating Temperature -40°C~75°C / -40°F~167°F
(72V model: -40°C~60°C / -40°F~140°F)
Storage Temperature -40°C~85°C / -40°F~185°F
Power Supply 44~57VDC on standard model
9.5~57VDC on 12V model
50.4~90VDC on 72V model
43~137.5VDC on 110V model with input isolation
PoE Budget 240W for 44~57V input
(55V input is recommended for 802.3at 30W applications)
80W for 12V input
120W for 24V input
80W for 72V/110V Input
PoE pin assignment M12 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W PoE at/ 15W PoE af.
Power Consumption Max. 13W 12V~48VDC input
Max. 16W 72VDC/110VDC input
Case Dimension IP67 Aluminum case
285mm(W)x200mm(H)x84.4mm(D)
IP54 Aluminum case
250mm(W)x179mm(H)x82mm(D)
Weight 2.1kgs(IP67) 1.8kgs(IP54)
Installation IP67 model: DIN Rail** and Wall Mount Design
IP54 model: Wall Mount Design
EMI & EMS FCC Class A,
CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11
Stability Testing IEC60068-2-32 (Free fall), EN61373 (Shock and Vibration)
MTBF 217,019 hrs
Verifications & report EN50155/EN50121-3-2/EN50121-4 verification
EN45545-2 R24/R25 (EN ISO 4589-2, EN ISO 5659-2, NF X70-100-1 & 2) Fire & Smoke verification
Safety EN 60950-1 (Standard model and 110V model)
Warranty 5 years

Software Specifications

Management SNMP v1 v2c, v3/ Web/Telnet/CLI
SNMP MIB RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
LLDP MIB*
RSTP MIB*
Private MIB
ITU G.8032 Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)
Support various ring/chain topologies
Includes train dynamic coupling ring
Enhanced G.8032 ring configuration with ease
Co-exist with RSTP on different ports
PoE Management
  1. PoE Detection to check if PD is hang up then restart the PD
  2. PoE Scheduling to On/OFF PD upon routine time table
  3. On/ Off, voltage, current, watts, temperature
PTP v2 Support hardware-based IEEE1588 PTP v2, End to End (2-step) and Peer to Peer (2-step) modes in Transparent Clock, with 4 10/100/1000T
User friendly UI
  1. Auto topology drawing
  2. Topology demo
  3. Auto configuration for G.8032(auto mode) for single ring
  4. Complete CLI for professional setting
Port Trunk with LACP LACP Port Trunk: 8 Trunk groups/Maximum 16 trunk members
LLDP Supports LLDP to allow switch to advise its identification and capability on the LAN
CDP Cisco Discovery Protocol for topology mapping
Environmental Monitoring System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status
VLAN Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP(256 groups)**, QinQ*
IPv6/4 Present
Spanning Tree Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree
Quality of Service The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP
Class of Service Support IEEE802.1p class of service, per port provides 8 priority queues
QoS by VLAN Tagged QoS by VLAN for all devices in the network
IP Security Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
Login Security Supports IEEE802.1X Authentication/RADIUS
Port Mirror Support 3 mirroring types: “RX, TX and Both packet”
Network Security Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
Ingress/Egress ACL L2/L3
SSL/ SSH for Management
HTTPS for secure access to the web interface
TACACS+ for Authentication
IGMP Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP**
MVR Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
Bandwidth Control Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.
RTC Built-in Real Time Clock to keep track of time always
Flow Control Supports Flow Control for Full-duplex and Back Pressure for Half-duplex
System Log Supports System log record and remote system log server
SMTP/Text SMS Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile
Relay Alarm Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V
Protection
  1. Miss-wiring avoidance
  2. Repowered auto ring restore
  3. Loop protection
SNMP Trap Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. PoE ping failure
  7. Power failure
  8. Environmental abnormal
DHCP Provide DHCP Client/ DHCP Server/DHCP Option 82/ DHCP Option 82 server/ Port based&VLAN based DHCP distribution (DHCP relay agent)
Mac based DHCP Server Assign IP address by Mac that can include dumb switch in DHCP network
DNS Provide DNS client feature and support Primary and Secondary DNS server.
SNTP Supports SNTP to synchronize system clock in Internet
Firmware Update Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
N-Key Configurator** RJ45 dongle for firmware upgrade, auto / editable configuration backup/restoration
Configuration
upload and download
Supports text configuration file for system quick installation
IfAlias Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface
*Future release
**Optional