Webmaster
IGS-3408DSFP
IGS-3408DSFP : Switch LANTECH managed
8 10/100/1000T + 4 100/1000M SFP L2+ Industrial Managed Switch w/PTP V2

IGS-3804DSFP : Switch LANTECH manageable
- Support PTPv2 two-step transparent clock @ all ports
- Enhanced G.8032 ring protection < 20ms with auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP
- Miss-wiring avoidance & Repowered auto ring restore (node failure protection)
- User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
- Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port&VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, ACL, IPv6, SMS
- Environmental Monitoring for temp., voltage & current**
OVERVIEW
Lantech IGS-3408DSFP is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 4 1000M SFP which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, enhanced mode for easy configuration and aggregation ring*, comprehensive QoS, QoS by VLAN, advanced security including ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.
Lantech IGS-3408DSFP features hardware-based PTP IEEE1588 v2 two-step function which can allow 8 10/100/1000T and 4 100/1000 SFP uplinks to synchronize the network with precise accuracy (under 1μs). It has RTC (Real Time Clock) inside that can keep track of current time.
The IGS-3408DSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IGS-3408DSFP is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 and relay agent function (port&vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.
The user friendly UI, innovative auto topology drawing and topology demo makes IGS-3408DSFP much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IGS-3408DSFP supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.
Lantech IGS-3408DSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 16 MSTI. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.
The configuration file of Lantech IGS-3408DSFP can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
The IGS-3408DSFP DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IGS-3408DSFP will immediately send an email & SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
The optional environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.
The Lantech IGS-3408DSFP is designed with dual power supply at 24/48VDC or single power supply at 90~305VAC/120~430VDC. Featured with relay contact alarm function, the IGS-3408DSFP is able to connect with alarm system in case of power failure. The IGS-3408DSFP also provides ±4000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
Lantech IGS-3408DSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.
The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.
- 8 10/100/1000T + 4 1000M SFP (Total 12 Ports Switch)
- IEEE 1588 PTP v2 two-step (under 1μs)
- Back-plane (Switching Fabric): 24Gbps
- 16K MAC address table
- DDM to support SFP diagnostic function***
- Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
- 9KB Jumbo frame supported on all ports
- User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting
- Enhanced G.8032 Ring protection in 20ms < 256 switches
- Support various ring/chain topologies, including dynamic coupling ring& aggregation ring*
- Enhanced G.8032 ring configuration with ease
- Auto ring configuration(auto mode) for single ring
- Co-exist with RSTP on different ports
- Aggregation ring for ring redundancy and bandwidth combination*
- Dual DC input from 18V~57VDC, HV model with single 90~305VAC or 120~430VDC power input
- Provides EFT protection ±4000 VDC for power line.
- Supports ±6000 VDC Ethernet ESD protection
- LACP load balancing to distribute the load*
- Built-in RTC (Real Time Clock) to keep track of time
- Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority
- IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy
- 4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*
- Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**
- DHCP server / client / Port&Vlan based DHCP distribution / DHCP Option 82 supported
- Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
- Bandwidth Control
- Ingress packet filter and egress rate limit
- Broadcast/multicast packet filter control
- Relay alarm output system events
- Miss-wiring avoidance
- LED indicator
- Email, traps, or SMS notification
- Repowered auto ring restore
- Ensure the switches in a ring to survive after power breakout is back
- The status can be shown in NMS when each switch is back
- TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade
- System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters
- Security
- SSL/SSH/ACL L2&L3
- Port Security: MAC address entries/Filter/MAC-Port binding
- IP Security: IP address security management to prevent unauthorized intruder.
- Management access control with priority
- Login Security: IEEE802.1X/RADIUS
- HTTPS for secure access to the web interface
- Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application
- Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow
- Multicast VLAN registration* for metro video
- IGMPv1,v2,v3 with Query mode for multi media; GMRP**
- Factory reset button to restore setting to factory default
- Watchdog design to auto reboot switch CPU is found dead
- Optional environmental monitoring for system input voltage, current, ambient temperature
- Supports DIDO (Digital Input/Digital Output)
- IP30 metal housing with DIN rail and Wall-mount** design
Hardware Specifications
| Standards | IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE802.3ab 1000Base-T IEEE802.3z Gigabit fiber IEEE802.3x Flow Control and Back Pressure IEEE802.3ad Port trunk with LACP IEEE802.1d Spanning Tree IEEE802.1w Rapid Spanning Tree IEEE802.1s Multiple Spanning Tree IEEE 802.3ad Link Aggregation Control Protocol (LACP) IEEE 802.1AB Link Layer Discovery Protocol (LLDP) IEEE 802.1X User Authentication (Radius) IEEE802.1p Class of Service IEEE802.1Q VLAN Tag |
| Switch Architecture | Back-plane (Switching Fabric): 24Gbps |
| Transfer Rate | 14,880pps for Ethernet port 148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Ethernet / Gigabit Fiber port |
| CPU | Marvell 800Mhz |
| RAM | 256M Byte |
| Flash | 128M Byte |
| Mac Address | 16K MAC address table |
| Jumbo frame | 9KB on all ports |
| Connectors | 10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function Mini-GBIC: 4 x 100/1000 SFP socket with DDM RS-232 connector: RJ-45 type Power & P-Fail connector: 1 x 6-pole terminal block DIDO : 1 x 6-pole terminal block |
| Network Cable | 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) 1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) |
| Optical Cable | 1.25Gbps: Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm) Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm) 125Mbps: Multi mode: 0 to 2 km/ 5 km, 1310 nm (62.5/125 μm) Single mode: 0 to 30 km, 1310 nm (62.5/125 μm) WDM 1.25Gbps: Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm) WDM 125Mbps: Single mode: 0 to 20 km/ 40 km/ 60 km/ 80 km, 1310 nm (9/125 μm); 0 to 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm) |
| Protocol | CSMA/CD |
| LED | Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red) Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green) |
| DI/DO | 2 Digital Input (DI) : Level 0: -30~2V / Level 1: 10~30V Max. input current:8mA 2 Digital Output(DO): Open collector to 40 VDC, 200mA |
| Operating Humidity | 5% ~ 95% (Non-condensing) |
| Operating Temperature | -20°C~60°C / -4°F~140°F (Standard model) -40°C~75°C / -40°F~167°F(-E model) |
| Storage Temperature | -40°C~85°C / -40°F~185°F |
| Power Supply | Dual 18~57VDC (Standard model) Single 90~305VAC/120~430VDC (HV model) |
| Power Consumption | 10W |
| Case Dimension | Metal case. IP-30, 74 (W) x 105 (D) x 152 (H) mm (Standard model) 74 (W) x 135 (D) x 152 (H) mm (HV model) |
| Weight | 900 g |
| Installation | DIN Rail and Wall Mount** Design |
| EMI & EMS | FCC Class A, CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11 |
| Stability Testing | IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) |
| MTBF | NA |
| Warranty | 5 years |
Software Specifications
| Management | SNMP v1 v2c, v3/ Web/Telnet/CLI |
| SNMP MIB | RFC 1215 Traps MIB, RFC 1213 MIBII RFC 1158 MIBII RFC 1157 SNMP MIB, RFC 1493 Bridge MIB, RFC 1573 IF MIB RFC 2674 VLAN MIB, Partial RFC 1643 EtherLike, Partial RFC 1757 RMON, RFC 2674 Q-Bridge MIB; Bridge MIB, RFC 2790 Host Resource MIB LLDP MIB* RSTP MIB* Private MIB |
| ITU G.8032 | Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode) Support various ring/chain topologies Includes dynamic coupling ring & aggregation ring* Enhanced G.8032 ring configuration with ease Co-exist with RSTP on different ports |
| PTP v2 | Support hardware-based IEEE1588 PTPv2 in 1μs, End to End (2-step) and Peer to Peer (2-step) modes in Transparent Clock, with 8 10/100/1000T and 4 100/1000 SFP |
| User friendly UI |
|
| Port Trunk with LACP | LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members Aggregation ring for ring redundancy and bandwidth combination* |
| LLDP | Supports LLDP to allow switch to advise its identification and capability on the LAN |
| CDP | Cisco Discovery Protocol for topology mapping |
| Environmental Monitoring** | System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models) |
| VLAN | Port Based VLAN IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.) GVRP(256 groups)**, QinQ* |
| IPv6/4 | Present |
| Spanning Tree | Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree |
| Quality of Service | The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP |
| Class of Service | Support IEEE802.1p class of service, per port provides 8 priority queues |
| QoS by VLAN | Tagged QoS by VLAN for all devices in the network |
| IP Security | Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
| Login Security | Supports IEEE802.1X Authentication/RADIUS |
| Port Mirror | Support 3 mirroring types: “RX, TX and Both packet” |
| Network Security | Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. 802.1X access control for port based and MAC based authentication/MAC-Port binding Management access control with priority 256 Policy based Access Control List SSL/ SSH for Management HTTPS for secure access to the web interface TACACS+ for Authentication |
| IGMP | Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP** |
| MVR | Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application |
| Bandwidth Control | Support ingress packet filter and egress packet limit. The egress rate control supports all of packet type. Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet. The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit. |
| RTC | Built-in Real Time Clock to keep track of time always |
| Flow Control | Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
| System Log | Supports System log record and remote system log server |
| SMTP/Text SMS | Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile |
| Relay Alarm | Provides one relay output for port breakdown, power fail and alarm. Alarm Relay current carry ability: 1A @ DC24V |
| Protection |
|
| SNMP Trap | Up to 10 trap stations; trap types including:
|
| DHCP | Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&VLAN based DHCP distribution (DHCP relay agent) |
| Mac based DHCP Server | Assign IP address by Mac that can include dumb switch in DHCP network |
| DNS | Provide DNS client feature and support Primary and Secondary DNS server. |
| SNTP | Supports SNTP to synchronize system clock in Internet |
| Firmware Update | Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade |
| Configuration upload and download |
Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default |
| IfAlias | Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface |
*Future Release
**Optional
***Optional DDM SFP required
| 8350-806 | IGS-3408DSFP | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; Dual 24/48VDC |
| 8350-807 | IGS-3408DSFP-E | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -40°C to 75°C; Dual 24/48VDC |
| 8350-808 | IGS-3408DSFP-M | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; Environmental monitoring; Dual 24/48VDC |
| 8350-809 | IGS-3408DSFP-M-E | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -40°C to 75°C; Environmental monitoring; Dual 24/48VDC |
| 8350-853 | IGS-3408DSFP-HV | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; Single 90~305VAC/120~430VDC |
| 8350-854 | IGS-3408DSFP-HV-E | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -40°C to 75°C; Single 90~305VAC/120~430VDC |
| 8350-8531 | IGS-3408DSFP-HV-M | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; Environmental monitoring; Single 90~305VAC/120~430VDC |
| 8350-8541 | IGS-3408DSFP-HV-M-E | 8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -40°C to 75°C; Environmental monitoring; Single 90~305VAC/120~430VDC |
OPTIONAL ACCESSORIES – DIN Rail Power
| Model name | Description |
|---|---|
| AD1048-24FS | 24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.) |
| AD1024-24F | 24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.) |
| AD1240-48S | 48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
| AD1120-48F | 48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
Formation disponible sur la parametrisation des Switches L2+
PB-PRO1-PCIE
Carte universelle PROFIBUS, format PCI Express, pour une utilisation Maitre ou Esclave
Simple ou double canaux, l’interface PB-PRO1 est une interface au format PCI Express pour l’intégration de PC/ Servers dans une architecture PROFIBUS. la carte PB-PRO1-PCIE, permet d’utiliser vos PC comme “contrôleur”, Système de contrôle d’applications et panneau opérateur.

| Master/Slave, Single Channel 1) | Slave, Single Channel 1) | Master/Slave, Dual Channel | |
| PROFIBUS Protocol | |||
| DP-V0 Master | |||
| DP-V1 Master: Acyclic C2 Services | |||
| FMS | |||
| FDL | |||
| DP-V0 Slave | |||
| Fieldbus Connection | 9-Pin D-Sub Female, RS485, Galvanically Isolated | ||
| Transfer Rates | 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s | ||
| PC Interface | PCI Express x1 According to PCIe r1.0a and CEM 1.1, 512 KB Shared RAM per Channel | ||
| Operating Temperature | 0 oC .. +55 oC | ||
| Storage Temperature | -20 oC .. +70 oC | ||
| Relative Humidity | < 90%, Non-Condensing | ||
| Dimensions [mm] | 168 x 69 | 168 x 69 | 168 x 103 |
| Power Supply | |||
| Supply Voltage | 3.3V / 12V (± 5%) DC | ||
| Current Consumption [mA] | typ. 500 / 90 | typ. 500 / 90 | typ. 640 / 170 |
| Drivers available for | Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10 | ||
| Conformity | |||
| PB-PRO 1-PCIE (PB-PRO 1-PCIE/LP1)) | Master/Slave, Single Channel 1) |
| PB-PRO 1S-PCI E(PB-PRO 1S-PCIE/LP1)) | Slave, Cingle Channel 1) |
| PB-PRO 2-PCIE | Master/Slave, Dual Channel |
Scope of Delivery
| PC interface Board, CD with Drivers, Documentation and Sample Programs |
Additional Products and Services
| OPC-PB | PROFIBUS OPC Server for DP-V0 / DP-V1 |
| DCF-DY-4100 | OPC Server for S7 / S5 |
| TRA-PB-TECH | PROFIBUS Technology Training |
1) Also Available with Low Profile Slot Bracket
IGS-5408DSFP
8 10/100/1000T + 4 100/1000M SFP L2+ Industrial Managed Switch w/PTP V2
- Support PTPv2 two-step transparent clock @ all ports
- Enhanced G.8032 ring protection < 20ms with auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP
- Miss-wiring avoidance & Repowered auto ring restore (node failure protection)
- User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI
- Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port&VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, ACL, IPv6, SMS
- Environmental Monitoring for temp., voltage & current**
- USB slot for edited restoration and auto backup
THLink – PROFINET
PROFINET : THLink Profinet
Diagnostic PROFINET : Indépendant du contrôleur
L’outil de diagnostic THLink PROFINET est totalement indépendant du contrôleur. Il permet le “monitoring” des réseaux PROFINET. Les données sont collectés dans des réseaux comprenant jusqu’à 254 Noeuds et mise à la disposition des utilisateurs via le logiciel THScope. THLink PROFINET facile d’utilisations’intègre facilement sans intéraction avec le fonctionnement de l’installation existante.
| Functionality |
|
| Input Voltage | 24 VDC (18 VDC … 32 VDC) |
| Current consumption | max. 180 mA |
| Current consumption relay contact | max. 100 mA |
| Operating Temperature | -40 °C … +75 °C |
| Relative Air Humidity | 5 … 95 % (no condensation) |
| Ethernet Ports | RJ-45 (10Base-T/100Base-TX) |
| Supported SD Cards | See Release Notes |
| Mounting | 35 mm DIN rail |
| Dimensions (HxWxD) | 22.5 x 99 x 114.5 mm |
| Weight | 120 g |
| Certifications | CE |
-
Data Sheets
-
Drivers & Software
-
Manuals & Documentation
| GDA-JA-003034 | TH LINK PROFINET |
Scope of Delivery
| Hardware | TH LINK PROFINET |
| Documentation | Installation Manual, Release Note (by download) |
Additional Products and Services
| LRA-JY-003024 | TH SCOPE (software key) |
| LRL-JY-003025 | TH SCOPE (hardware key) |
| LRA-JY-003028 | TH LINK PC Industrial Ethernet (software key) |
| LRL-JY-003029 | TH LINK PC Industrial Ethernet (hardware key) |
| GDA-JY-003037 | TH LINK Industrial Ethernet |
| TRA-PN-TECH | Training “PROFINET Technology” |
| TRA-PN-CERTENG | Training “PROFINET Commissioning and Troubleshooting” |
TH LINK:
enablement of the following ports:
- HTTP Protocol: 80 TCP
- Firmware update: 1100 TCP
- communication with each other: 1123, 1124, 2364 UDP
- communication with TH SCOPE via Multicast: 2364 UDP
- communication with TH SCOPE via Unicast: 1151, 2365 UDP
There must be no firewall between the TH LINK and the PROFINET and/or EtherNet/IP devices.
TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.
- Enabling of HTTP port 80 – inbound and outbound
- Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
- Enabling of IP 224.0.5.128 port 2364 UDP outbound
- Enabling of UDP ports 2365 outbound and 2366 inbound
The following ports are used by TH SCOPE for internal communication only:
- Port 22
- Port 80
- Port 1100
- Ports 1123 – 1151
- Port 1500
- Port 1501
- Ports 2363 – 2366
- Ports 49152 – 49171
Produits qui pourrait vous intéresser
BC-230-PB
BC-230-PB : Testeur Profibus PA : Pour les Zones ATEX et non-ATEX


Le testeur PROFIBUS PA ( BC-230-PB) est un outil pratique et indispensable pour les tests de réseaux PROFIBUS PA ( Zone ATEX et non ATEX )
Test du bus PA, facile et rapide
Le moniteur de diagnostic est un outil polyvalent et indispensable pour la mesure des réseaux Profibus PA. C’est auss un produit ATEX, ce qui en fait un appareil utilisable en zone a risque. Pas de besoin de batterie ni de source électrique externe.
| put voltage: | Fieldbus mode: 8 to 32 VDC, USB mode: 4.1 to 5.5 VDC |
| Max. input current: | Fieldbus mode: 10 mA *, USB mode: 30 mA |
| Power dissipation: | Fieldbus mode: max. 320 mW (at 32 VDC), USB mode: max. 165 mW (at 5.5 VDC) |
| Operating temperature: | –20 to +50 °C ** |
| Dimensions: | 146 x 88 x 28 mm |
| Weight: | 378 g |
| Case material: | ABS |
| DC voltage measurement range: | 8 to 32 VDC ± 0.5 VDC |
| Signal level measurement range: | 0.12 to 2 Vpp ±10% ±0.025 Vpp |
| LF noise measurement range: | 50 Hz to 4 kHz, 0 to 1000 mVpp ±15% ±25 mVpp *** |
| FF noise measurement range: | 9 kHz to 40 kHz, 0 to 1000 mVpp ±10% ±25 mVpp *** |
| HF noise measurement range: | 90 kHz to 350 kHz, 0 to 250 mVpp ±20% ±25 mVpp *** |
| Conformity | CE, FCC |
| Hazardous area approvals | FM USA and Canada: —Class I Division 2 Groups A, B, C and D T4 —Class I Zone 2 Group IIC T4 —Class I Division 1 Groups A, B, C and D T4 —Class I Zone 0 and 1 Ex/AEx ia IIC T4 ATEX Ex ia IIC T4 ATEX Ex nL IIC T4 ATEX Ex ic IIC T4 |
| Data transfer to PC | Via supplied PC software for Windows 2000, XP and VISTA, Windows 7 (32/64 bit) and USB interface version 1.1 or 2.0 |
| * In fieldbus mode the BC-230-PB is powered by the fieldbus and draws approximately 9.4 mA of current from the segment (depending on bus voltage and ambient temperature). ** Display update speed is impaired below –10°C. *** Vpp = Volts peak-to-peak; excessive noise adjacent to the fieldbus frequency (FF) band will prevent the BC-230-PB from reading the fieldbus data and thus reduce functionality. |
| BC-230-PB | Diagnostic Monitor for PROFIBUS PA |
Scope of Delivery
| Hardware | Diagnostic Monitor for PROFIBUS PA (BC-230-PB), connection cables, carrying case |
| Software | PC software (in English) on CD-ROM |
| Documentation | Manual (in English), certificates (in English) |
Additional Products and Services
| PB-LSZ-CHB3 | Digital fieldbus leakage current clamp for locating EMC problems, 40 Hz … 1,000 Hz, Min/Max, Data Hold, measuring cables, supplied in handy case |
Pour toute demande, nous consulter
Ce produit fait partie de la famille des “Process automation”. Afin de connaitre notre gamme complete de produits, vous pouvez télécharger notre brochure : Process Automation.
PB-PRO1-PCI
PB-PRO1-PCI
Carte d’interface à un ou deux canaux au format PCI universel pour l’intégration des PC dans les architectures PROFIBUS en tant que contrôleurs de machines, applications de contrôle de supervision, dispositifs de terrain ou panneaux opérateurs.
Fonctionalité PROFIBUS Maître et esclave supportée
Le protocole requis pour le cas d’utilisation spécifique peut être sélectionnable par l’utilisateur et exécuté sur la carte PBpro PCI. En tant qu’esclave DP, la carte intègre le PC dans des architectures de contrôle superposées. Configurée comme maître DP, la carte transforme le PC lui-même en contrôleur. En tant que DP Master Class 2, il constitue la base des tâches de paramétrage et de gestion d’actifs. En outre, l’intégration dans des systèmes FMS ou des applications propriétaires est tout aussi simple et sans problème que l’accès direct au niveau de protocole le plus bas (FDL). Cela fait du PBpro PCI une solution d’interface universelle et permet aux fabricants d’optimiser leurs productions et l’inventaire pour leurs options PROFIBUS.
Intégration rapide grâce à l’interface adaptée
Le logiciel de pilote PROFIBUS inclus est complété par de nombreux exemples de programmes qui démontrent comment utiliser l’API PROFIBUS. Des exemples de programmes commentés montrent comment faire. Un serveur OPC Softing correspondant, qui est disponible en tant qu’interface standard facultative, se connecte rapidement et facilement à n’importe quelle application qui possède un client OPC intégré. Les applications typiques incluent la visualisation, les systèmes SCADA ou MES. Les outils de paramétrage compatibles FDT utilisent le PROFIdtm Communication DTM de Softing comme lien vers la carte. Utilisée avec le pilote STEP7 (gratuit), la carte peut également fournir un adaptateur PG / PC pour la programmation des automates Siemens.
Grande variété d’applications
la carte prend en charge de nombreux autres systèmes d’exploitation et environnements en temps réel. Sur demande, nous pouvons personnaliser les drivers, selon les spécifications du client.
| Master/Slave, Single Channel 1) | Slave, Single Channel 1) | Master/Slave, Dual Channel | |
| PROFIBUS Protocol | |||
| DP-V0 Master | |||
| DP-V1 Master: Acyclic C2 Services | |||
| DP-V2 Master 2) | |||
| FMS | |||
| FDL | |||
| DP-V0 Slave | |||
| Fieldbus Connection | 9-Pin D-Sub Female, RS485, Galvanically Isolated | ||
| Transfer Rates | 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s | ||
| PC Interface | PCI V2.2, 128 KB Shared RAM per Channel | ||
| Operating Temperature | 0oC..+55oC | ||
| Storage Temperature | -20oC..+70oC | ||
| Relative Humidity | < 90%, Non-Condensing | ||
| Dimensions [mm] | 168×64 | 168×64 | 168×107 |
| Power Supply | |||
| Supply Voltage | 5V/3.3V(±5%)DC | ||
| Current Consumption [mA] | Typ. 500 / 200 | Typ. 500 / 200 | Typ. 700 / 300 |
| Drivers available for | Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10 Linux |
||
| Conformity | |||
1) Also Available with Low Profile Slot Bracket
2) DP-V2 Available for Custom Integration. Please contact Softing to discuss your specific requirements.
Downloads
-
Drivers & Software
-
Articles & White Papers
-
Certificates
-
Data Sheets
| PB-PRO 1-PCI (PB-PRO 1-PCI/LP1)) | Master/Slave, Single Channel 1) |
| PB-PRO 1S-PCI (PB-PRO 1S-PCI/LP1)) | Slave, Single Channel 1) |
| PB-PRO 2-PCI | Master/Slave, Dual Channel |
Scope of Delivery
| PC interface Board, CD with Drivers, Documentation and Sample Programs |
Additional Products and Services
| OPC-PB3) | PROFIBUS OPC Server for DP-V0 / DP-V1 |
| DCF-DY-41003) | OPC Server for S7 / S5 |
| TRA-PB-TECH | PROFIBUS Technology Training |
1) Also Available with Low Profile Slot Bracket
3) Requires PROFIBUS Master Interface Board
Formation disponible. Pour plus d’information, contactez nous
Testeur PROFIBUS : PB-T5 (BC-700-PB)
Testeur Profibus: SOFTING PB-T5 ( BC-700-PB ) : Pour Test rapide et facile; bus physique, bus de communication et câblage de vos réseaux PROFIBUS
Le testeur PROFIBUS: ‘PROFIBUS Tester 5’ (BC-700-PB) est un outil de diagnostic et de dépannage puissant pour tester les câbles, mesurer les signaux et l’analyse de la communication de réseaux PROFIBUS. Il est alimenté par batterie et fournit un affichage graphique, ce qui permet des résultats rapides lorsque vous travaillez en mode autonome. En option, également le réseau PROFIBUS PA peut être analysé. En outre, le BC-700-PB soutient l’exportation des résultats des tests pour l’analyse avancée.
Le testeur profibus vous permet le test des câbles, bus physique et bus de communication “All-In-One”
- Combinaison de testeur de signal, oscilloscope à mémoire, protocolanalyzer, simulateur de maître et la fonctionnalité de testeur de câble en un seul outil de diagnostic
- Mode autonome, plus des diagnostics basés sur PC étendues
- Adaptés pour l’installation, la configuration et la mise en service, la documentation, les tests d’acceptation, l’optimisation du réseau, la maintenance préventive, le dépannage ainsi que des tests de laboratoire
Très mobile, le testeur de bus permet des tests, même sans ordinateur
- fonctionnement sur batterie sans avoir besoin d’alimentation supplémentaire
- Affichage graphique fournissant facile à comprendre la présentation des résultats des tests
- tests de réseau complets en mode autonome sans nécessiter un ordinateur portable
Caractéristiques de diagnostic améliorée grâce à complément logiciel PC-Based
- De nombreuses fonctionnalités supplémentaires pour l’exécution, l’analyse et la gestion des tests de bus en mode PC (Tendance, Topologie Numériser, Master Simulator, Oscilloscope, analyseur Frame)
- Test rapide et test contrôlé par l’utilisateur pour l’évaluation de l’état du réseau facile à la simple pression d’un bouton
- Génération de rapports d’essais qui décrivent l’état actuel de l’installation PROFIBUS
- Idéal pour les utilisateurs moins expérimentés, ainsi que pour les spécialistes de bus de terrain
Adaptateur de mesure en option pour MBP (Manchester Coded Bus Powered) Physique
- Analyse spécifique du signal de support physique MBP (de feedingvoltage, type de signal, le signal de polarité, divergence bitrate)
- Analyse complète du protocole directement au niveau du segment PROFIBUS PA
| Diagnostics Functionality | |
| Protocol and Frame Analysis | PROFIBUS DP-V0 and DP-V1, automatic baud rate detection in the range of 9.6 kbit/s … 12 Mbit/s |
| Signal Analysis | PROFIBUS DP-V0, DP-V1, FMS and MPI |
| … via EIA-485 | Signal quality index 0 … 5,000, determined from signal wave form as well as signal/noise ratio and rise time; signal sampling with 8/16 samples per bit |
| … via MBP (requires optional adapter) |
Fieldbus feeding voltage: 0 V … 35 V at 0.1 V resolution, signal level: 100 mV … 1,200 mV at 10 mV resolution, signal polarity, bitrate divergence: ±1.2 % at 0.01 % resolution, signal sampling with 128 samples per bit |
| Oscilloscope Display (Not Available for MBP) |
Test range: ±5 V at 10 mV resolution (differential), 0 V … 15 V at 15 mV resolution (A or B to DGND); sampling rate: up to 384 Msamples/s; sampled points: 2,400 (signal details), 8,192 (oscilloscope analysis) |
| Topology Scan (Not Available for MBP) |
Active, maximum distance: 230 m, accuracy: ±2 m |
| Cable Test (Not Available for MBP) |
Active, supported cable segment length: 5 m … 1,500 m, accuracy: 5 % |
| Operation | Via graphical colour display, four function keys and scrollwheel including central push-button or via PC/notebook |
| Internal Memory Capacity | 3 user-definable network directories (segment and test location) for storing quick tests, trend logs and cable test results Trend logging: max. 99 hours |
| Trigger | IN: L = 0 V .. 0.8 V; H = 2.4 V .. 24 V; pulse > 10 μs, active high OUT: approximately 5 V, active low (connection to storage oscilloscope) |
| PC Operating Software | PROFIBUS Diagnostics Suite, see separate datasheet for details |
| Connectors | |
| EIA-485 (PROFIBUS DP) | PROFIBUS D-sub connector, 9 pins, power supply for external bus termination |
| MBP (PROFIBUS PA) | Connector, 3 pins, for screw terminals at optinal measuring adapter, measuring cable set including 3 probes(adapter for MBP measurement is attached to D-sub connector) |
| USB | V 2.0, high speed 480 Mbit/s, galvanically isolated |
| Dimensions (H x W x D) | 35 mm x 220 mm x 110 mm |
| Power Supply | Built-in three-cell lithium-ion battery supporting 11.1 VDC or external AC adapter 100 VAC … 240 VAC, 50/60Hz (galvanically isolated) The rechargeable battery has a runtime of up to 5 hours (runtime depends on the performed test functionality and rate of wear of the rechargeable battery) Battery is charged via external AC adapter |
| Operating/Storage Temperature | Operating temperature: 0 °C … 50 °C, storage temperature: -20 °C … 70 °C |
| Relative Humidity | Air humidity: 10 % … 90 % without condensation |
| Weight | Test tool, no cable: approximately 0.75 kg; complete carrying case: approximately 4.2 kg |
| Conformity | CE, FCC, VCCI |
| ATV-DDA-NN-006014 | PROFIBUS Tester 5 (BC-700-PB) |
| ATV-DDL-NN-006012 | PROFIBUS Tester 5 (BC-700-PB) with Oscilloscope Option |
| ATV-LRA-NN-006011 | Oscilloscope Option (Oscilloscope view in stand-alone mode) |
| ATV-DDL-NL-006010 | PROFIBUS PA option for BC-700-PB (BC-700-PB serial number required for order placement) |
Scope of Delivery
| Hardware | PROFIBUS Tester 5 (BC-700-PB), power supply unit 100 VAC … 240 VAC, 50/60 Hz with connecting cables for Europe and USA, adaptor cables, carrying case Measuring adapter BC-700-H1, measuring cable set (for PROFIBUS PA option) |
| Software | PROFIBUS Diagnostics Suite (PC software for Windows on CD-ROM) BC-700-PB upgrade license (on CD-ROM, for PROFIBUS PA option) |
| Documentation | Device Manual, “Getting Started“ Manual |
Additional Products and Services
| ATV-ACA-NN-006031 | EIA-485 D-Sub adapter cable for testing operational networks with reduced influence on segment operation |
| ATV-ACA-NN-006033 (view product) |
Adapteur D-Sub vers M12, fourni avec un T et bus M12 de terminaison, pour profibus DP |
| ATV-PB-LSZ-CHB3 (view product) |
Pince pour mesure des courants de fuite. Localise les problèmes électromagnétique ( EMC ) . 40 ..1000 Hz, MIN/MAX, Data Hold, Cable pour mesure, fourni avec son étui. |
| ATV-BC-PBMB-PB-S (view product) |
D-Sub Service Interface with Active Bus Termination and 90° Angled Connector for PROFIBUS DP |
| ATV-BC-M12DP-PB (view product) |
M12 Service Interface for PROFIBUS DP, Comprising M12 T-Piece, End Cap and M12 Connection Cable (1 m) |
PROFIBUS Diagnostics SuiteUniversal Software for All Diagnostic Tools of the bus check Family |
||
PC software for performing, evaluating and managing tests of bus physics, bus communication and cabling in PROFIBUS networks. The application is extremely easy to use, with a quick test available at a click of the mouse.![]() |
||
One Software for All Diagnostic Products
Suitable for the Fieldbus Novice
Functionality for All Diagnostic Tasks
|
Technical Data
| Operating Systems: PC Hardware* |
RAM | 500 MB for Windows XP 1 GB for Windows 7, Windows 8 |
| Processor | 1 GHz for recording at baud rates up to 1.5 Mbit/s 2 GHz for recording at baud rates over 1.5 Mbit/s |
|
| Screen Resolution | 1024 x 768 pixels (XGA) | |
| USB Interface 2.0 | ||
| Supported Operating Systems | Windows XP, Windows 7, Windows 8, Windows 10 |
* The above minimum requirements are only general guidelines. Requirements may vary depending on the PC/notebook used.
Fieldbus Shield Digital Leakage Current Clamp – Locating EMC Problems

Measures leakage currents, e.g. leakage and fault currents, and current pick-up of instruments without breaking the circuit. Measurements according to DIN VDE 0701/0702 and the German BetrSichV (BGV A3, VBG 4).
- Reliably Detects Even Very Small Improper Shield Currents Resulting from EMC Problems.
Functionality
- Leakage current measurement
- Differential current measurement
- Voltage and resistance measurement
- Frequency range for AC current / voltage 40 Hz…1 kHz
- Acoustical continuity test
- MIN/MAX and relative value measurement
- Manual selection of the measurement range
- Integrated data hold
- Additional analog bar graph display
- Clamp opening 30 mm
- Auto power off
Included in Package
Digital leakage current clamp, 2 batteries 1.5 V IEC LR6, carrying case, measuring cables (1 x red, 1 x black) and user manual.
Order Number
DDA-ZZ-004010
M12 Service Interface for PROFIBUS DP
Interface for Providing an Access Point to Test PROFIBUS Networks With M12 Connectors
Provides an access point for testing PROFIBUS networks with M12 connectors.
- Allows Testing the Bus During Operation
Application
The service interface is inserted between two bus stations. When not in use, the service output of the T piece is closed with an end cap. At baud rates of 1.5 Mbit/s or higher, use the supplied cable to ensure that the required minimum distance between bus stations is maintained.
Included in Package
T piece (protection class IP68) with end cap and a 1 m DP cable fitted with a male/female M12 connector on each end.
Order Number
ATV-ACA-NN-006034
M12 adaptor PROFIBUS Tester PB-T5
Application example:
Interface for Providing an Access Point to Test PROFIBUS Networks With M12 Connectors
M12 Adaptor for PB-T5
- Allows Testing the Bus During Operation
Application
The service interface is inserted between two bus stations. When not in use, the service output of the T piece is closed with an end cap. At baud rates of 1.5 Mbit/s or higher, use the supplied cable to ensure that the required minimum distance between bus stations is maintained.
Included in Package
M12 Adaptor for PB-T5
Order Number
ATV-ACA-NN-006033

- [ VIDEO ] Comment utiliser le Profibus Testeur 5
- [ VIDEO ] PB-T5 – Logiciel PB-DIAG TOOL
- [ VIDEO ] PB-T5
Les clients intéressé par ce produit peuvent aussi etre intéressé par :
- TH Link PROFIBUS ( pour la paramétrisation FDT/DTM )
- Testeur PROFIBUS PA pour Zone ATEX
- Pince pour la mesure des courants de Fuites :
- Valise de protection IP67 : Etanche et robuste, une garantie pour la protection de votre matériel