<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SWITCH-eng | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/product-category/switch/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Thu, 26 Feb 2026 06:12:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>SWITCH-eng | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TPES-0008CB-54-24VI</title>
		<link>https://www.atevatech.net/produit/tpes-0008cb-54-24vi/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=tpes-0008cb-54-24vi</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 06 Aug 2025 16:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=39659</guid>

					<description><![CDATA[<p>8 10/100TX IP54 rated PoE at/af Ethernet<br />
Switch w/M12 connectors; -40°C to 75°C;<br />
9~36VDC dual input; E- marking certified; w/PoE<br />
ethernet galvanic isolation</p>
The post <a href="https://www.atevatech.net/produit/tpes-0008cb-54-24vi/">TPES-0008CB-54-24VI</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>TPES-0008CB-54-24VI</h1>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3>LANTECH : 8 10/100TX (PoE at/af) EN50155 Ethernet Switch</h3>
<div class="col-md-12">
<ul class="list-unstyled">
<li><i class="fa fa-check color-green"></i> IEEE802.3at/af up to 30W PoE output (for PoE model)</li>
<li><i class="fa fa-check color-green"></i> Dual power inputs 9~36V (24VI model) or 16.8~56V (24TVI model); with galvanic isolation between input power, PoE (for PoE model) and all Ethernet ports</li>
<li><i class="fa fa-check color-green"></i> Wide Operating Temperature from -40°C to 75°C</li>
<li><i class="fa fa-check color-green"></i> Efficient PoE configuration when ignition off (-IGN model)</li>
<li><i class="fa fa-check color-green"></i> Inrush current prevention; polarity reverse protection</li>
<li><i class="fa fa-check color-green"></i> IP54 Aluminum housing for best heat dissipation and preventing moist ingress</li>
<li><i class="fa fa-check color-green"></i> EN50155/50121-3-2/50121-4 and EN45545-2 Fire &amp; Smoke verification</li>
<li><i class="fa fa-check color-green"></i> E-mark certificate for vehicle (24VI model)</li>
<li><i class="fa fa-check color-green"></i> ITxPT* labeled w/ignition function (24VI-IGN model)</li>
</ul>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="627" height="163" src="https://www.atevatech.net/wp-content/uploads/2025/08/Selection_337.png" class="vc_single_image-img attachment-full" alt="" title="Selection_337" srcset="https://www.atevatech.net/wp-content/uploads/2025/08/Selection_337.png 627w, https://www.atevatech.net/wp-content/uploads/2025/08/Selection_337-300x78.png 300w, https://www.atevatech.net/wp-content/uploads/2025/08/Selection_337-400x104.png 400w" sizes="(max-width: 627px) 100vw, 627px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519"><span class="vc_tta-title-text">Technical Data</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>OVERVIEW</h4>
<p>Lantech T(P)ES-0008CB is an 8 10/100 Base-TX with M12-connectors EN50155 unmanaged Ethernet switch with IP54 rated protection which meets the high-reliability requirements demanded by industrial rolling stock applications.</p>
<p><strong><em>Redundant dual 24VI/24TVI input with max PoE budget; inrush current prevention and polarity reverse protection</em></strong><br />
The T(P)ES-0008CB 24VI model accepts 9~36VDC dual input and 24TVI model accepts 16.8~56VDC with galvanic isolation to PoE and all Ethernet ports. PoE feeding with 80W budget from internal power. The redundant power input design prevents inrush current and safeguards against polarity reversal.</p>
<p><strong><em>E-marking certificate, ITxPT*; ISO 7637-2 compliant and extended working temperature</em></strong><br />
The T(P)ES-0008CB is designed to meet with critical network environment with IP54 enclosure and M12 connectors for protection against dust and water. It has passed harsh environmental testing to comply with Industrial EMI and Safety standards as well as stability testing such as Free fall, Shock, and vibration. It is labeled with ITxPT* public transport standards and also compliant with ISO 7637-2 which protects switch from being damaged by high voltage that could be found at vehicle cranky start. For greater flexibility in application the T(P)ES-0008CB supports an extended operating temperature range from -40°C to 75°C.</p>
<p><strong><em>Efficient PoE configuration when ignition off</em></strong><br />
Supports optional PoE feeding OFF timer (1/5/10mins or others) at ignition off mode to prevent car battery drain-out. (-IGN model) The E-marking certificate makes it the most suitable switch for bus, carriage, other vehicle applications as well as for industrial areas where the power source is limited with 12V or 24V but has demand of IP surveillance or VoIP applications. ※The optional PoE off-timer is available after February 23, 2024.</p>
<div align="right"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Data</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>SPECIFICATIONS</h4>
<div class="col-md-12">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-cogs"></i> Hardware Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">IEEE Standard</td>
<td valign="top">IEEE802.3 10BASE-T Ethernet<br />
IEEE802.3u 100BASE-T Ethernet<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3at/af Power over Ethernet (For PoE Model)</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Connector</td>
<td valign="top">10/100TX: 8 x M12, 4-pole D-coded, Female with auto MDI/MDI-X function<br />
Power connector: 1 x M12, 4-pole A coded, Male<br />
1 x M12, 5-pole A-coded, Male (-IGN model)</td>
</tr>
<tr>
<td valign="top">Rotary Switch</td>
<td valign="top">Rotary switch for delay time configuration (-24VI-IGN model)</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green),<br />
Ethernet: Link/Activity (Green)<br />
PoE: (Green)</td>
</tr>
<tr>
<td valign="top">PoE pin assignment</td>
<td valign="top">M12 port # 1~ # 8 support IEEE 802.3at/af End-point. Per port provides up to 30W</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">Dual input<br />
9~36VDC (24VI model)<br />
16.8~56VDC (24TVI model)</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">3.5W without PoE</td>
</tr>
<tr>
<td valign="top">Power Budget</td>
<td valign="top">Total 80W @ 24VDC and above</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% to 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-40°C ~ 75°C (-40°F ~ 167°F)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C ~ 85°C (-40°F ~ 185°F)</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Aluminum case, IP54 rated<br />
135mm(W)x165mm(H)x76.5mm(D)</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">700g</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">Wall Mount Design</td>
</tr>
<tr>
<td valign="top">EMC</td>
<td valign="top">FCC Part 15, Subpart B ICES-003 Issue 7,<br />
EN 55035:2017/A11:2020,<br />
EN 55032:2015/A11:2020,<br />
IEC 61000-4-2:2008,<br />
IEC 61000-4-3:2020,<br />
IEC 61000-4-4:2012,<br />
IEC 61000-4-5:2014+AMD1:2017 CSV,<br />
IEC 61000-4-6:2023,<br />
IEC 61000-4-8:2009,<br />
IEC 61000-6-2:2016,<br />
IEC 61000-6-4:2018,<br />
EN IEC 61000-6-2:2019,<br />
EN IEC 61000-6-4:2019,<br />
BS EN 55035:2017+A11:2020,<br />
BS EN 55032:2015+A11:2020</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">EN 61373:2010 (Shock and Vibration)</td>
</tr>
<tr>
<td valign="top">Verifications &amp; Report</td>
<td valign="top">EN 50155:2021,<br />
EN 50121-4:2016/A1:2019,<br />
EN 50121-3-2:2016/A1:2019,<br />
EN 50124-1:2017,<br />
EN 45545-1, EN 45545-2 Fire &amp; Smoke verification</td>
</tr>
<tr>
<td valign="top">Vehicle certificate</td>
<td valign="top">E24 marking* (24VI model)<br />
ITxPT* labeled (24VI-IGN model)</td>
</tr>
<tr>
<td valign="top">MTBF</td>
<td valign="top">1,240,250 hours<br />
1,502,043 hours (Non PoE)</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>
</div>
<div align="right"></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc7012-d519" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>All model packages include M12 caps and wall mount bracket. All standard models are non-coating, optional coating models are available with –C model name.</p>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">P/N</th>
<th width="15%">Model name</th>
<th width="75%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8351-142</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/E24.png" alt="" width="20" /></td>
<td>TPES-0008CB-54-24VI</td>
<td>8 10/100TX PoE at/af Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-red rounded">9~36VDC dual power inputs w/ PoE galvanic isolation</span>; E-marking certified; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8351-1421</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/en50155.png" alt="" width="20" /></td>
<td>TPES-0008CB-54-24TVI</td>
<td>8 10/100TX PoE at/af Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-orange rounded">16.8~56VDC dual power inputs w/ PoE galvanic isolation</span>; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8351-1422</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/E24.png" alt="" width="20" /></td>
<td>TPES-0008CB-54-24VI-IGN</td>
<td>8 10/100TX PoE at/af Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-red rounded">9~36VDC dual power inputs w/ PoE galvanic isolation</span>; E-marking and ITxPT certified w/ignition; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8351-1426</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/E24.png" alt="" width="20" /></td>
<td>TES-0008CB-54-24VI</td>
<td>8 10/100TX Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-red rounded">9~36VDC dual power inputs w/ galvanic isolation</span>; E-marking certified; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8351-14261</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/en50155.png" alt="" width="20" /></td>
<td>TES-0008CB-54-24TVI</td>
<td>8 10/100TX Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-orange rounded">16.8~56VDC dual power inputs w/ galvanic isolation</span>; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8351-1427</span><br />
<img decoding="async" src="https://www.lantechcom.tw/global/eng/assets/img/icons/E24.png" alt="" width="20" /></td>
<td>TES-0008CB-54-24VI-IGN</td>
<td>8 10/100TX Ethernet Switch w/M12 connectors; <span class="text-highlights text-highlights-red rounded">9~36VDC dual power inputs w/ galvanic isolation</span>; E-marking and ITxPT certified w/ignition; <span class="text-highlights text-highlights-blue rounded">IP54 rated</span>; -40°C to 75°C</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – Connector</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="20%">Model name</th>
<th width="80%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>ECON120005PF</td>
<td>5 pin M12 (Female) A-coded 180 degree crimp type connector for power supply</td>
</tr>
<tr>
<td>ECONM12-04A(F)-C-180</td>
<td>4 pin M12 (Female) A-coded 180 degree crimp type connector for power supply</td>
</tr>
<tr>
<td>ECONM12-04D(M)-C-180</td>
<td>4 pin M12 (Male) D-coded 180 degree crimp type connector for data</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – Cable</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="20%">Model name</th>
<th width="80%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>ECONM12-5P(F)70CM CABLE</td>
<td>5 pin M12 (Female) A-coded 90 degree cable for power supply, 70cm</td>
</tr>
<tr>
<td>ECONM12-4P(F)1.5M CABLE</td>
<td>4 pin M12 (Female) A-coded 90 degree cable for power supply, 150cm</td>
</tr>
<tr>
<td>ECAB124030MJS</td>
<td>4 pin M12 (Male) D-coded 180 degree RJ45 STP cable for data, 300cm</td>
</tr>
<tr>
<td>ECONM12-05A(F) to MCP 6P-20CM CABLE</td>
<td>5 pin M12 (Female) A-coded 180 degree to 6 pin MCP power cable, 20cm (For ignition models)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/tpes-0008cb-54-24vi/">TPES-0008CB-54-24VI</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IPGS-3408GSFP</title>
		<link>https://www.atevatech.net/produit/ipgs-3408gsfp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipgs-3408gsfp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 10 May 2023 16:24:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=35192</guid>

					<description><![CDATA[<h3>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h3>
The post <a href="https://www.atevatech.net/produit/ipgs-3408gsfp/">IPGS-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h1>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="800" height="471" src="https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E.png" class="vc_single_image-img attachment-full" alt="IPES-3408GSFP-E" title="IPGS-3408GSFP-E" srcset="https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E.png 800w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-400x236.png 400w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-300x177.png 300w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-768x452.png 768w" sizes="(max-width: 800px) 100vw, 800px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>PoE Managed switch : 8* 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h2>
<div class="col-md-12">
<ul class="list-unstyled">
<li><i class="fa fa-check color-green"></i> Support IEEE802.3at/af up to 30W per port</li>
<li><i class="fa fa-check color-green"></i> PoE management incl. Detection and Scheduling</li>
<li><i class="fa fa-check color-green"></i> Enhanced G.8032 ring protection &lt; 20ms for single ring. Supports auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP; support MRP ring</li>
<li><i class="fa fa-check color-green"></i> Miss-wiring avoidance &amp; Node failure protection</li>
<li><i class="fa fa-check color-green"></i> User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI</li>
<li><i class="fa fa-check color-green"></i> Support LACP link aggregation, IGMP v3/router port, MLD snooping, DHCP server &amp; DHCP Option82; DHCP Snooping, Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH v2/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3,TACACS+**, QinQ</li>
<li><i class="fa fa-check color-green"></i> Protocol based VLAN; IPv4 Subnet based VLAN</li>
<li><i class="fa fa-check color-green"></i> Environmental Monitoring for temp., voltage &amp; current**</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-35205" src="https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-300x80.png" alt="" width="442" height="118" srcset="https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-300x80.png 300w, https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-400x107.png 400w, https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624.png 521w" sizes="(max-width: 442px) 100vw, 442px" /></p>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview266a-758d"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Technical Data</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Misc</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Lantech IPGS-3408GSFP is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 4 1000M SFP w/8 PoE 802.3af/at ports which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode , multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) for Ciscoworks to detect the switch info and show on L2 map topology.</p>
<p>&nbsp;</p>
<p><strong><em>Up to 8 PoE at/af ports w/advanced PoE management </em></strong><br />
Compliant with 802.3af/at standard, the Lantech IPGS-3408GSFP is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPGS-3408GSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.</p>
<p>&nbsp;</p>
<p><strong><em>Miss-wiring avoidance, Loop protection, Node failure protection</em></strong><br />
The IPGS-3408GSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-3408GSFP is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.</p>
<p>&nbsp;</p>
<p><strong><em>DHCP option 82 &amp; Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server</em></strong><br />
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.</p>
<p>&nbsp;</p>
<p><strong><em>User friendly GUI, Auto topology drawing</em></strong><br />
The user friendly UI, innovative auto topology drawing and topology demo makes IPGS-3408GSFP much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.</p>
<p>&nbsp;</p>
<p><strong><em>Enhanced G.8032 ring, 16 MSTI MSTP; MRP ring</em></strong><br />
Lantech IPGS-3408GSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.</p>
<p>&nbsp;</p>
<p>MRP (Media Redundancy Protocol) can be supported for industrial automation networks.</p>
<p>&nbsp;</p>
<p><strong><em>Editable configuration file</em></strong><br />
The configuration file of Lantech IPGS-3408GSFP can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p>&nbsp;</p>
<p><strong><em>QoS by VLAN for legacy device</em></strong><br />
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p>&nbsp;</p>
<p><strong><em>QinQ, QoS and GVRP supported</em></strong><br />
It supports the QinQ, QoS, GVRP for large VLAN segmentation.</p>
<p>&nbsp;</p>
<p><strong><em>802.1X security by MAC address</em></strong><br />
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host&#8217;s source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.</p>
<p>&nbsp;</p>
<p><strong><em>IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection</em></strong><br />
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.</p>
<p>&nbsp;</p>
<p><strong><em>Event log &amp; message; 2 DI + 2DO</em></strong><br />
In case of event, the IPGS-3408GSFP is able to send an email to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO when disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.</p>
<p>&nbsp;</p>
<p><strong><em>Optional environmental monitoring for switch inside information (-M model) </em></strong><br />
The optional environmental monitoring can detect switch overall temperature, voltage, total PoE load and current where can send the SNMP traps, email when abnormal.</p>
<p>&nbsp;</p>
<p><strong><em>Wide range dual DC powered input with galvanic isolation; Relay contact alarm, High ESD protection</em></strong><br />
The Lantech IPGS-3408GSFP is designed with dual power supply at 24/48VDC or single power supply at 90~305VAC/120~430VDC. Featured with relay contact alarm function, the IPGS-3408GSFP is able to connect with alarm system in case of power failure. The IPGS-3408GSFP also provides ±2000V EFT/SURGE and ±4000 VDC (Contact) / ±8000 VDC (Air) Ethernet ESD protection, which can reduce unstable situation caused by power line and Ethernet.</p>
<p>&nbsp;</p>
<p><strong><em>Industrial hardened design for extended temperature operation </em></strong><br />
Lantech IPGS-3408GSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.</p>
<p>&nbsp;</p>
<p>The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Data</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>FEATURES</h4>
<ul>
<li>8 10/100/1000T + 4 1000M SFP w/8 PoE 802.3af/at ports (Total 12 Ports Switch)</li>
<li>Embedded 8 PoE ports IEEE802.3af/at function to feed power up to 30W@54V; 15W @ 48V per port for active operation</li>
<li>PoE voltage boost from 12V to 54V (12V model)</li>
<li>PoE management including PoE detection and scheduling for PD (power devices)</li>
<li>Back-plane (Switching Fabric): 24Gbps, non-blocking</li>
<li>16K MAC address table</li>
<li>DDM to support SFP diagnostic function***
<ul>
<li>Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance</li>
</ul>
</li>
<li>10KB Jumbo frame on all ports</li>
<li>User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting</li>
<li>Enhanced G.8032 Ring protection in 20ms for single ring
<ul>
<li>Support various ring/chain topologies, including dynamic coupling ring</li>
<li>Enhanced G.8032 ring configuration with ease</li>
<li>Auto ring configuration(auto mode) for single ring</li>
<li>Ring covers multicast on different ports</li>
</ul>
</li>
<li>Provides EFT protection ±2000 VDC for power line.</li>
<li>Supports ±4000 VDC (Contact) and ±8000 VDC (Air) Ethernet ESD protection</li>
<li>LACP load balancing to distribute the load*</li>
<li>Built-in RTC (Real Time Clock) to keep track of time</li>
<li>Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority</li>
<li>IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy</li>
<li>4K 802.1Q VLAN, Port based VLAN, GVRP, QinQ*</li>
<li>Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console</li>
<li>DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server; Port based DHCP server; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server</li>
<li>Mac based DHCP server to assign IP address</li>
<li>MLD Snooping for IPv6 Multicast stream</li>
<li>Bandwidth Control
<ul>
<li>Ingress packet filter and egress rate limit</li>
<li>Broadcast/multicast packet filter control</li>
</ul>
</li>
<li>Relay alarm output system events</li>
<li>Miss-wiring avoidance
<ul>
<li>LED indicator</li>
<li>Email or traps notification</li>
</ul>
</li>
<li>Node failure protection
<ul>
<li>Ensure the switches in a ring to survive after power breakout is back</li>
<li>The status can be shown in NMS when each switch is back</li>
</ul>
</li>
<li>TFTP/HTTP firmware upgrade</li>
<li>System Event Log and SNMP Trap for alarm support; 32 RMON counters</li>
<li>Security
<ul>
<li>SSL/SSH v2/INGRESS/EGRESS ACL L2/L3</li>
<li>MAC address table: MAC address entries/Filter/MAC-Port binding</li>
<li>IP Security: IP address security management to prevent unauthorized intruder.</li>
<li>Management access control with priority</li>
<li>Login Security: IEEE802.1X/RADIUS</li>
<li>HTTPS for secure access to the web interface</li>
<li>TACACS+**</li>
</ul>
</li>
<li>Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application</li>
<li>IGMP router port to assign query in ring and for reversed multicast video flow</li>
<li>Multicast VLAN registration* for metro video</li>
<li>IGMPv1,v2,v3 with Query mode for multi media; GMRP</li>
<li>Factory reset button to restore setting to factory default</li>
<li>Watchdog design to auto reboot switch CPU is found dead</li>
<li>Diagnostic including Ping / DDM information</li>
<li>Optional environmental monitoring for system input voltage, current, ambient temperature</li>
<li>Supports DIDO (Digital Input/Digital Output)</li>
<li>Fanless design, no moving parts</li>
<li>IP30 metal housing with DIN rail and Wall-mount** design</li>
<li>Auto Provision to verify switch firmware with the latest or certain version</li>
</ul>
<div align="right">
<h6>*Future Release</h6>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: IPGS-3408GSFP</h4>
<p>Technical specifications and features.</p>
</div>
<p><a class="dl-link" href="https://atevatech.aztgrp.net:8080/index.php/s/YSxncryNjAABT88" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-611</span></td>
<td>IPGS-3408GSFP-48V</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-612</span></td>
<td>IPGS-3408GSFP-48V-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-613</span></td>
<td>IPGS-3408GSFP-48V-M</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-614</span></td>
<td>IPGS-3408GSFP-48V-M-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-617</span></td>
<td>IPGS-3408GSFP-12V</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-618</span></td>
<td>IPGS-3408GSFP-12V-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-6171</span></td>
<td>IPGS-3408GSFP-12V-M</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-6181</span></td>
<td>IPGS-3408GSFP-12V-M-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Misc</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4></h4>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-cogs"></i> Hardware Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Standards</td>
<td valign="top">IEEE 802.3 10Base-T Ethernet<br />
IEEE 802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z Gigabit fiber<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1s Multiple Spanning Tree<br />
IEEE 802.3ad Link Aggregation Control Protocol (LACP)<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE 802.1X User Authentication (Radius)<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.3at/af Power over Ethernet</td>
</tr>
<tr>
<td valign="top">Switch Architecture</td>
<td valign="top">Back-plane (Switching Fabric): 24Gbps</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port<br />
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port</td>
</tr>
<tr>
<td valign="top">CPU</td>
<td valign="top">Marvell 800Mhz</td>
</tr>
<tr>
<td valign="top">RAM</td>
<td valign="top">256M Byte</td>
</tr>
<tr>
<td valign="top">Flash</td>
<td valign="top">128M Byte</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Jumbo frame</td>
<td valign="top">10KB on all ports</td>
</tr>
<tr>
<td valign="top">Connectors</td>
<td valign="top">10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function<br />
Mini-GBIC: 4 x 1000 SFP socket with DDM<br />
RS-232 connector: RJ-45 type<br />
Power &amp; P-Fail connector: 1 x 6-pole terminal block<br />
DIDO : 1 x 6-pole terminal block</td>
</tr>
<tr>
<td valign="top">Network Cable</td>
<td valign="top">10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td valign="top">Optical Cable</td>
<td valign="top"><strong>1.25Gbps:</strong><br />
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)<br />
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)<br />
<strong>WDM 1.25Gbps:</strong><br />
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)</td>
</tr>
<tr>
<td valign="top">Protocol</td>
<td valign="top">CSMA/CD</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), RM (Green)<br />
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)</td>
</tr>
<tr>
<td valign="top">DI/DO</td>
<td valign="top">2 Digital Input (DI) :<br />
Level 0: -30~2V / Level 1: 10~30V<br />
Max. input current:8mA<br />
2 Digital Output(DO): Open collector to 40 VDC, 200mA</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% ~ 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-20°C~60°C / -4°F~140°F (Standard model)<br />
-40°C~75°C / -40°F~167°F(-E model)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C~85°C / -40°F~185°F</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">44~56VDC (48V model)<br />
9.5~56VDC (12V model)</td>
</tr>
<tr>
<td valign="top">PoE Budget</td>
<td valign="top">240W for 45~56V input<br />
(55V input is recommended for 802.3at 30W applications)<br />
120W for 24V input<br />
90W for 12V input<br />
Higher PoE budget can be applied upon request. **</td>
</tr>
<tr>
<td valign="top">PoE pin assignment</td>
<td valign="top">RJ-45 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W PoE at/ 15W PoE af.<br />
Positive (VCC+): RJ-45 pin 1,2.<br />
Negative (VCC-): RJ-45 pin 3,6.</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">10W</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Metal case. IP-30,<br />
74 (W) x 105 (D) x 152 (H) mm (Standard model)<br />
74 (W) x 105 (D) x 152 (H) mm (12V model)<br />
96.3 (W) x 135 (D) x 152 (H) mm (-E model)</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">900 g</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">DIN Rail and Wall Mount** Design</td>
</tr>
<tr>
<td valign="top">EMI &amp; EMS</td>
<td valign="top">FCC Class A,<br />
CE EN55032 Class A, CE EN55024 ,<br />
CE EN61000-4-2, CE EN61000-4-3,<br />
CE EN61000-4-4, CE EN61000-4-5,<br />
CE EN61000-4-6, CE EN61000-4-8<br />
CE EN61000-6-2<br />
BS EN55032, BS EN55024,<br />
BS EN61000-4-2, BS EN61000-4-3,<br />
BS EN61000-4-4, BS EN61000-4-5,<br />
BS EN61000-4-6, BS EN61000-4-8</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">IEC60068-2-32 (Free fall),<br />
IEC60068-2-27 (Shock),<br />
IEC60068-2-64 (Vibration)</td>
</tr>
<tr>
<td valign="top">MTBF</td>
<td valign="top">782,391 hours</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-desktop"></i> Software Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Management</td>
<td valign="top">SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td valign="top">SNMP MIB</td>
<td valign="top">MIB<br />
MIBII<br />
SNMP MIB<br />
Bridge MIB<br />
IF MIB<br />
RMON MIB<br />
Private MIB</td>
</tr>
<tr>
<td valign="top">ITU G.8032</td>
<td valign="top">Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)<br />
Support various ring/chain topologies<br />
Includes dynamic coupling ring<br />
Enhanced G.8032 ring configuration with ease<br />
Ring covers multicast on different ports</td>
</tr>
<tr>
<td valign="top">PoE Management</td>
<td valign="top">
<ol>
<li>PoE Detection to check if PD hangs then restart the PD</li>
<li>PoE Scheduling to On/OFF PD upon routine time table</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Per Port PoE Status</td>
<td valign="top">On/ Off, voltage, current, watts, temperature</td>
</tr>
<tr>
<td valign="top">User friendly UI</td>
<td valign="top">
<ol>
<li>Auto topology drawing</li>
<li>Topology demo</li>
<li>DDM threshold monitoring with dB values***</li>
<li>Complete CLI for professional setting</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Port Trunk with LACP</td>
<td valign="top">LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members</td>
</tr>
<tr>
<td valign="top">LLDP</td>
<td valign="top">Supports LLDP to allow switch to advise its identification and capability on the LAN</td>
</tr>
<tr>
<td valign="top">CDP</td>
<td valign="top">Cisco Discovery Protocol for topology mapping</td>
</tr>
<tr>
<td valign="top">Environmental Monitoring**</td>
<td valign="top">System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models)</td>
</tr>
<tr>
<td valign="top">VLAN</td>
<td valign="top">Port Based VLAN<br />
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096)<br />
GVRP, QinQ, Protocol based VLAN; IPv4 Subnet based VLAN</td>
</tr>
<tr>
<td valign="top">Spanning Tree</td>
<td valign="top">Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree</td>
</tr>
<tr>
<td valign="top">Quality of Service</td>
<td valign="top">The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4</td>
</tr>
<tr>
<td valign="top">Class of Service</td>
<td valign="top">Support IEEE802.1p class of service, per port provides 8 priority queues</td>
</tr>
<tr>
<td valign="top">MLD Snooping</td>
<td valign="top">Support IPv6 Multicast stream</td>
</tr>
<tr>
<td valign="top">Login Security</td>
<td valign="top">Supports IEEE802.1X Authentication/RADIUS</td>
</tr>
<tr>
<td valign="top">Port Mirror</td>
<td valign="top">Support 3 mirroring types: “RX, TX and Both packet”</td>
</tr>
<tr>
<td valign="top">Network Security</td>
<td valign="top">Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.<br />
802.1X access control for port based and MAC based authentication/MAC-Port binding<br />
Management access control with priority<br />
Ingress/Egress ACL L2/L3<br />
SSL/ SSH v2 for Management<br />
HTTPS for secure access to the web interface<br />
TACACS+** for Authentication</td>
</tr>
<tr>
<td valign="top">IGMP</td>
<td valign="top">Support IGMP snooping v1,v2,v3; 1024 multicast groups; IGMP router port ; IGMP query; GMRP</td>
</tr>
<tr>
<td valign="top">Static MAC-Port bridge</td>
<td valign="top">Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application</td>
</tr>
<tr>
<td valign="top">Bandwidth Control</td>
<td valign="top">Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td valign="top">RTC</td>
<td valign="top">Built-in Real Time Clock to keep track of time always</td>
</tr>
<tr>
<td valign="top">Flow Control</td>
<td valign="top">Supports Flow Control for Full-duplex and Back Pressure for Half-duplex</td>
</tr>
<tr>
<td valign="top">System Log</td>
<td valign="top">Supports System log record and remote system log server</td>
</tr>
<tr>
<td valign="top">Relay Alarm</td>
<td valign="top">Provides one relay output for port breakdown, power fail and alarm.<br />
Alarm Relay current carry ability: 1A @ DC24V</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">
<ol>
<li>Miss-wiring avoidance</li>
<li>Node failure protection</li>
<li>Loop protection</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">SNMP Trap</td>
<td valign="top">Up to 10 trap stations; trap types including:</p>
<ol>
<li>Device cold start</li>
<li>Authorization failure</li>
<li>Port link up/link down</li>
<li>DI/DO open/close</li>
<li>Typology change(ITU ring)</li>
<li>PoE ping failure</li>
<li>Power failure</li>
<li>Environmental abnormal**</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">DHCP</td>
<td valign="top">Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server</td>
</tr>
<tr>
<td valign="top">Mac based DHCP Server</td>
<td valign="top">Assign IP address by Mac</td>
</tr>
<tr>
<td valign="top">DNS</td>
<td valign="top">Provide DNS client feature</td>
</tr>
<tr>
<td valign="top">Diagnostic</td>
<td valign="top">Support Ping and DDM information</td>
</tr>
<tr>
<td valign="top">SNTP</td>
<td valign="top">Supports SNTP to synchronize system clock in Internet</td>
</tr>
<tr>
<td valign="top">Firmware Update</td>
<td valign="top">Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade</td>
</tr>
<tr>
<td valign="top">Configuration<br />
upload and download</td>
<td valign="top">Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default</td>
</tr>
<tr>
<td valign="top">IfAlias</td>
<td valign="top">Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface</td>
</tr>
<tr>
<td valign="top">Auto Provision</td>
<td valign="top">To verify switch firmware with the latest or certain version</td>
</tr>
</tbody>
</table>
</div>
</div>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/ipgs-3408gsfp/">IPGS-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FINISAR &#8211; FTLF8524P2BNV</title>
		<link>https://www.atevatech.net/produit/finisar-ftlf8524p2bnv-2/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=finisar-ftlf8524p2bnv-2</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 25 Jan 2023 17:00:15 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=34229</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Module SFP Finisar’s FTLF8524P2xNV</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Finisar 500m Duplex SFP Transceiver | FTLF8524P2BNV</h2>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p style="text-align: justify"><strong>Product description</strong></p>
<p style="text-align: justify">Write a product description integrating the word or group of keywords to be referenced of at least 50 words. The keyword or group of keywords should be repeated at least 2 or 3 times in this paragraph.<br />
The photos arranged on the left are preferably in 4/3 format, it is possible to change the format by indicating the resolution. It is very important to specify a file name understandable by google (keyword) and to repeat it in the &#8220;alt&#8221; attribute.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Technical Details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Finisar 500m Duplex SFP Transceiver | FTLF8524P2BNV</h2>
<p>The Finisar FTLF8524P2BNV 1000BASE-SX Ethernet transceiver is a Duplex SFP transceiver for optical communications, rated for distances up to 500m and a maximum bandwidth of 4.25Gbps. The FTLF8524P2BNV transceiver operates at 850nm wavelength. 4Gb/s 850nm FC -20 to 85C, Rate Select SFP. Finisar FTLF8524P2xNV SFP transceivers are compatible with the small form factor pluggable MSA.. Note: Due to manufacturer restrictions, Finisar FTLF8524P2BNV is a non-cancellable &amp; non-returnable product. Please call to confirm stock. This product is manufactured by Finisar USA, ships directly from Finisar and is covered by full manufacturer warranty within the USA. For most up-to-date specifications, refer to datasheets on Finisar website. Images are for illustrative purposes only.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>Finisar 1000BASE-SX Ethernet SFP</li>
<li>Up-to 500m over MMF @ 4.25Gbps</li>
<li>850nm Duplex SFP Transceiver</li>
<li>-10º &#8211; 85º Operating Case Temperature</li>
<li>SFF-8724 Digital optical monitoring</li>
<li>Hot-swappable for SFP LC ports</li>
<li>Finisar Standard 1 Year Warranty</li>
<li>Metal enclosure, for lower EMI</li>
<li>SFP MSA / IEEE Std 802.3</li>
<li>Finisar FTLF8524P2BNV is RoHS complian</li>
<li>1000BASE-SX Ethernet</li>
<li>1.063/2.125/4.25 Gb/s FC</li>
<li>Rate selectable version</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: FINISAR FTLF8524P2BNV</h4>
<p>SFP transceiver specifications.</p>
</div>
<p><a class="dl-link" href="/ftp/SFP/FTLF8524P2BNV_datasheet.pdf" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Ref: FTLF8524P2BNV</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/finisar-ftlf8524p2bnv-2/">FINISAR – FTLF8524P2BNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IGS-0008B</title>
		<link>https://www.atevatech.net/produit/igs-0008b/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=igs-0008b</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 18 Jul 2021 08:52:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=30381</guid>

					<description><![CDATA[<p>Galvanic isolation for dual 48V, 12V, 24V input with max PoE budget<br />
The IPGS-0008B supports IEEE802.3at/af standard which can feed HI-power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, high power wireless AP etc.</p>
The post <a href="https://www.atevatech.net/produit/igs-0008b/">IGS-0008B</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3>8 10/100/1000T Industrial Unmanaged Switch</h3>
<div class="col-md-12">
<ul class="list-unstyled">
<li><i class="fa fa-check color-green"></i> Supports 10K bytes jumbo frame</li>
<li><i class="fa fa-check color-green"></i> Wide-range dual isolated power 9.5~60V input</li>
<li><i class="fa fa-check color-green"></i> Provides ESD/ EFT protection; Voltage transient protection</li>
<li><i class="fa fa-check color-green"></i> DIN rail and wall mount** design with IP30 enclosure</li>
</ul>
<h5></h5>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874ab2163-094e5af5-15ab3ae8-d10aabed-e0ab1d8c-f48ab230-3bcab0d2-6c6ab9ee-2c29" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874ab2163-094e5af5-15ab3ae8-d10aabed-e0ab1d8c-f48ab230-3bcab0d2-6c6ab9ee-2c29"><span class="vc_tta-title-text">Technical details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441334172163-09433af5-15d53338-d10a833d-e00a338c-33827230-3bc330d2-633d49ee-2c29" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441334172163-09433af5-15d53338-d10a833d-e00a338c-33827230-3bc330d2-633d49ee-2c29"><span class="vc_tta-title-text">Reference</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29"><span class="vc_tta-title-text">Training</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29"><span class="vc_tta-title-text">Downloads</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Le switch Lantech IGS-0008B, est un switch 8-Port 10/100/1000T Industriel. Afin d&#8217;augmenter la fiabilité, il fournit une alimentation redondante, detecte la tension d&#8217;entée et accèpte une tension étendue de 9.5v à 60VDC.</p>
<p>Pour une meilleure stabilité et performance, le IGS-008B supporte les trames &#8220;jumbo &#8221; jusqu&#8217;à 10k Octet.</p>
<p>Le IGS -0008B, est conçu pour satisfaire les demandes les plus exigentes de l&#8217;industrie et est fournit avec un boitier IP30. Il a été testé pour satisfaire les exigence de compatibilité electromagnetique et interférences. C&#8217;est un switch robuste, anti choc, stabilité aux tests de vibration.</p>
<p>IGS-0008B is compact in size and easy to be installed with DIN rail and wall mount** kits. IGS-0008B is applicable in many kinds of industrial environments.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874ab2163-094e5af5-15ab3ae8-d10aabed-e0ab1d8c-f48ab230-3bcab0d2-6c6ab9ee-2c29" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874ab2163-094e5af5-15ab3ae8-d10aabed-e0ab1d8c-f48ab230-3bcab0d2-6c6ab9ee-2c29" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-cogs"></i> Hardware Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Standards</td>
<td valign="top">IEEE 802.3 10Base-T<br />
IEEE 802.3u 100Base-TX<br />
IEEE 802.3ab 1000Base-T<br />
IEEE802.3x Flow Control and Back Pressure</td>
</tr>
<tr>
<td valign="top">Switch Architecture</td>
<td valign="top">Back-plane (Switching Fabric): 16Gbps</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port<br />
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Jumbo Frame</td>
<td valign="top">10Kbytes</td>
</tr>
<tr>
<td valign="top">Connectors</td>
<td valign="top">10/100/1000T: 8 x RJ-45</td>
</tr>
<tr>
<td valign="top">Network Cable</td>
<td valign="top">10Base-T: 2-pair UTP/STP Cat. 3, 4, 5, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5, 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td valign="top">Protocol</td>
<td valign="top">CSMA/CD</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green), Fault(Amber)<br />
Per port: Link/Activity (Green), Speed (1000Mbps Amber)</td>
</tr>
<tr>
<td valign="top">Reserve polarity protection</td>
<td valign="top">Present</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">9.5~60 VDC, Dual isolated input with removable terminal block</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">5 Watts</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% ~ 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-20°C~60°C / -4°F~140°F (Standard model)<br />
-40°C~75°C / -40°F~167°F (-E model)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C~85°C / -40°F~185°F</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Metal case. IP30,<br />
35mm (W) x 152mm (H) x 105mm (D)</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">DIN Rail and Wall Mount** Design</td>
</tr>
<tr>
<td valign="top">EMI &amp; EMS</td>
<td valign="top">FCC Class A,<br />
CE EN61000-4-2 (ESD),<br />
CE EN61000-4-3 (RS),<br />
CE EN-61000-4-4 (EFT),<br />
CE EN61000-4-5 (Surge),<br />
CE EN61000-4-6 (CS),<br />
CE EN61000-4-8,<br />
CE EN61000-4-11,<br />
CE EN61000-4-12,<br />
CE EN55022 Class A, CE EN55024</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">IEC60068-2-32 (Free fall)<br />
IEC60068-2-27 (Shock)<br />
IEC60068-2-6 (Vibration)</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441334172163-09433af5-15d53338-d10a833d-e00a338c-33827230-3bc330d2-633d49ee-2c29" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441334172163-09433af5-15d53338-d10a833d-e00a338c-33827230-3bc330d2-633d49ee-2c29" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Reference</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<thead>
<tr>
<th width="10%">P/N</th>
<th width="15%">Modèle</th>
<th width="75%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-835</span></td>
<td>IGS-0008B</td>
<td>8 10/100/1000T Switch Industriel, Utilisation &#8220;Standard&#8221; de Temperature (-20°C~60°C)</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-836</span></td>
<td>IGS-0008B-E</td>
<td>8 10/100/1000T Switch Industriel, Utilisation en température &#8220;étendu&#8221; (-40°C~75°C)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>ACCESSOIRES OPTIONNELS</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Nom du Modele</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1048-24FS</td>
<td>24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1024-24F</td>
<td>24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1240-48S</td>
<td>48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1120-48F</td>
<td>48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Training</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Pas de formation particulière sur un switch non administrable.</p>
<p>Formation disponible sur switches administrables. &#8211; N&#8217;hésitez pas à nous contacter.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d49ee-2c29" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: IGS-0008B</h4>
<p>Technical specifications.</p>
</div>
<p><a class="dl-link" href="/ftp/LANTECH/LANTECH_Datasheets/Entry_Switches/D-IGS-0008B.pdf" target="_blank" rel="noopener">Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>User Manual (Hardware)</h4>
<p>Hardware installation and configuration guide.</p>
</div>
<p><a class="dl-link" href="https://atevatech.aztgrp.net/index.php/s/a8tsQsgHkgKMaG7" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/igs-0008b/">IGS-0008B</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IES-2208CA-DNV</title>
		<link>https://www.atevatech.net/produit/ies-2208ca-dnv/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ies-2208ca-dnv</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 18 Jul 2021 08:41:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=30372</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Switch LANTECH : IES-2208CA-DNV</h2>
<h3>Switch Industriel IES-2208CA-DNV : 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo</h3>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>IES-2208CA-DNV : 8* 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo, administrable</h2>
<p>&nbsp;</p>
<ul>
<li>Certification DNV pour réseaux embarqués marine et plate-forme Off-Shore</li>
<li>Fonction Pro-Ring pour la gestion des topologies réseau en anneau</li>
<li>Temps de cicatrisation inférieur à 20 ms</li>
<li>Alimentation protégée contre les inversions de polarité et sur-charge en courant</li>
</ul>
<p><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/c1d2-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/dnv-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/ul-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/fcc-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/ce-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/weee-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/rohs-150x150.png" width="55" height="55" /></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Détails Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Formation</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Téléchargement</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="tabs-caracteristique" class="ui-tabs-panel ui-widget-content ui-corner-bottom">
<ul>
<li>switch Ethernet administrable 12 ports:
<ul>
<li>8 ports 10/100TX</li>
<li>2 ports combo RJ48 10/100/1000TX et module fibre Mini-GBIC, dual mode 10/100/1000T</li>
</ul>
</li>
<li>méthode de commutation &#8220;stockage et retransmission&#8221;</li>
<li>taux de commutation: 5.6 Gbps</li>
<li>table d&#8217;adresses MAC 8K</li>
<li>bôiteir métal IP 30, fixation rail DIN et murale</li>
<li>entrées alimentation protégées contre les inversions de polarité et sur-charge en courant</li>
<li>fonction Pro-Ring pour la gestion des toplogies en anneau: Couple-Ring et Dual Homing, auto-cicatrisation en moins de 20 ms pour une toplogie à 50 switches</li>
<li>Port-Based VLAN, IEEE 802.1Q Tag VLAN, GVRP</li>
<li>802.1d Spanning Tree &amp; 802.1w RSTP</li>
<li>IGMP avec fonctions Snooping et Query pour les applications multimédia</li>
<li>entrée alimentation protégée contre les pics de tension jusqu&#8217;à 3000 Vdc</li>
<li>port Ethernet protégé contre les décharges électro-statiques, supporte jusqu&#8217;à 6000 Vdc</li>
<li>qualité de service (QoS) 802.1p, 4 files d&#8217;attente par port</li>
<li>journaux d&#8217;événements:
<ul>
<li>système Serveur/Client</li>
<li>alertes sytèmes envoyées par e-mail</li>
<li>sortie relais activée</li>
</ul>
</li>
<li>Port Trunk avec LACP</li>
<li>supporte 802.1ab LLDP</li>
<li>vecteurs SNMP :
<ul>
<li>démarrage à froid</li>
<li>états de fonctionnement de l&#8217;alimentation</li>
<li>défaut d&#8217;authentification</li>
<li>port Link up/Link down</li>
<li>modification de la toplogie en anneau</li>
</ul>
</li>
<li>mise à jour du microcode et sauvegarde/restauration du système par un accès TFTP</li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails Techniques</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Spécifications Matériel</p>
<p>&nbsp;</p>
<table border="1" width="540" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Normes standards</strong></td>
<td>IEEE802.3 10Base-T Ethernet<br />
IEEE802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z fibre Gigabit<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.1x Authentification (Radius)<br />
IEEE802.1ab LLDP</td>
</tr>
<tr>
<td><strong>Architecture</strong></td>
<td>Taux de commutation: 5.6 Gbps</td>
</tr>
<tr>
<td><strong>Taux de transfert</strong></td>
<td>Ethernet: 14 880 pps par port<br />
Fast Ethernet: 148 800 pps par port<br />
Gigabit Ethernet: 1,488,000 pps par port</td>
</tr>
<tr>
<td><strong>Adresse MAC</strong></td>
<td>Table d&#8217;adressage MAC 8K</td>
</tr>
<tr>
<td><strong>Mémoire Flash<br />
</strong></td>
<td>4 Mo</td>
</tr>
<tr>
<td><strong>Mémoire Vive</strong></td>
<td>32 Mo</td>
</tr>
<tr>
<td><strong>Connectique</strong></td>
<td>10/100TX: 8x ports RJ-45 avec fonction auto MDI/MDI-X<br />
10/100/1000T/SFP Combo port: 2x RJ-45 + 2x 100/1000 SFP socket.<br />
RS-232 connecteur: type RJ-45</td>
</tr>
<tr>
<td><strong>Câble réseau</strong></td>
<td>10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td><strong>Fibre optique<br />
</strong></td>
<td>Multi-mode: 50/125um~62.5/125um<br />
Mono-mode: 9/125um<br />
distance: 2km (Multi-mode)/30km (Mono-mode)<br />
Longueur d&#8217;onde: 1310nm (Multi-mode/Mono-mode)</td>
</tr>
<tr>
<td><strong>Protocole</strong></td>
<td>CSMA/CD</td>
</tr>
<tr>
<td><strong>Température de fonctionnement</strong></td>
<td>-40°C ~ 75°C</td>
</tr>
<tr>
<td><strong>Température de stockage</strong></td>
<td>-40°C ~ 85°C</td>
</tr>
<tr>
<td><strong>Protection </strong></td>
<td>surchage en courant<br />
inversion de polarité</td>
</tr>
<tr>
<td><strong>Alimentation</strong></td>
<td>9,5 à 60 Vdc<br />
alimentation avec entrées redondantes<br />
bloc de connections détachable<em><br />
</em></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td>74 (W) x 105 (D) x 182 (H) mm</td>
</tr>
<tr>
<td><strong>Indice de protection</strong></td>
<td>IP 30</td>
</tr>
<tr>
<td><strong>CEM</strong></td>
<td>FCC Class A,<br />
CE EN61000-4-2 (ESD),<br />
CE EN61000-4-3 (RS),<br />
CE EN61000-4-4 (EFT),<br />
CE EN61000-4-5 (Surge),<br />
CE EN61000-4-6 (CS),<br />
CE EN61000-4-8,<br />
CE EN61000-4-11,<br />
CE EN61000-6-2,<br />
CE EN61000-6-4</td>
</tr>
<tr>
<td><strong>Sécurité</strong></td>
<td>CE/EN60950-1</td>
</tr>
<tr>
<td><strong>Chocs et Vibrations</strong></td>
<td>IEC60068-2-32 (chute libre)<br />
IEC60068-2-27 (choc)<br />
IEC60068-2-6 (vibration)</td>
</tr>
<tr>
<td><strong>MTBF</strong></td>
<td>220 111 h</td>
</tr>
<tr>
<td><strong>Fixation</strong></td>
<td>En option : rail DIN ou murale</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Spécifications Logiciel</h2>
<p>&nbsp;</p>
<table border="1" width="560" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Administration</strong></td>
<td>SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td><strong>SNMP MIB<br />
</strong></td>
<td>RFC 1215 Traps MIB, RFC 1213 MIBII,<br />
RFC 1157 SNMP MIB, RFC 1493 Bridge MIB,<br />
RFC 2674 VLAN MIB, RFC 1643 EtherLike,<br />
RFC 1757 Rmon, RSTP MIB,<br />
Private MIB, PoE MIB, UPS MIB, LLDP MIB</td>
</tr>
<tr>
<td><strong>VLAN</strong></td>
<td>VLAN par port<br />
VLAN à balisage 802.1Q (256 entrées)/ VLAN ID ( VLAN ID de 1 à 4094)<br />
GVRP (256 Groupes)<br />
Double VLAN à balisage (Q in Q)*</td>
</tr>
<tr>
<td><strong>Port Trunk avec LACP</strong></td>
<td>LACP Port Trunk: 4 Trunk groupes/Maximum 4 membres trunk</td>
</tr>
<tr>
<td><strong>LLDP</strong></td>
<td>permet au switch de communiquer son identification et caractéistiques</td>
</tr>
<tr>
<td><strong>Gestion de boucle</strong></td>
<td>Spanning tree 802.1d et Rapid Spanning Tree 802.1w</td>
</tr>
<tr>
<td><strong>Pro-Ring<br />
</strong></td>
<td>Pro-Ring, topologies anneau simple, multi-anneaux et Dual Homing.<br />
fourni un chemin de repli et une auto-cicatrisation en moins de 10 ms</td>
</tr>
<tr>
<td><strong>Qualité de service<br />
</strong></td>
<td>QoS, service par port, balisage et IPV4, IPv4/IPv6</td>
</tr>
<tr>
<td><strong>Classe de Service<br />
</strong></td>
<td>802.1p, file d&#8217;attente à 4 niveaux de priorité par port</td>
</tr>
<tr>
<td><strong>Miroirs de port<br />
</strong></td>
<td>3 types: RX, TX et RX/TX</td>
</tr>
<tr>
<td><strong>IGMP</strong></td>
<td>IGMP snooping v1,v2<br />
diffusion de groupe (256) et requête IGMP</td>
</tr>
<tr>
<td><strong>Sécurité IP</strong></td>
<td>table de 10 adresses IP autorisées à administrer le switch</td>
</tr>
<tr>
<td><strong>Authentification</strong></td>
<td>IEEE802.1x, RADIUS, SSH, SSL</td>
</tr>
<tr>
<td><strong>Journal système<br />
</strong></td>
<td>enregistrement de l&#8217;activité du système<em><br />
</em></td>
</tr>
<tr>
<td><strong>Envoi d&#8217;alertes</strong></td>
<td>serveur SMTP, 6 comptes e-mails</td>
</tr>
<tr>
<td><strong>Serveur de temps<br />
</strong></td>
<td>synchronisation avec un serveur de temps sur Internet</td>
</tr>
<tr>
<td><strong>Sortie relais<br />
</strong></td>
<td>sur défauts de connection et alimentation</td>
</tr>
<tr>
<td><strong>Alerte SNMP</strong></td>
<td>1. démarrage à froid<br />
2. perte de lien<br />
3. re-connection<br />
4. défaut d&#8217;authentification<br />
5. défaut de configuration du port<br />
6. modification de la topologie de l&#8217;anneau</td>
</tr>
<tr>
<td><strong>DHCP</strong></td>
<td>client, serveur</td>
</tr>
<tr>
<td><strong>DNS</strong></td>
<td>fonction DNS client, supporte un serveur DNS primaire et secondaire</td>
</tr>
<tr>
<td><strong>Mise à jour firmware</strong></td>
<td>mise à jour via accès TFTP, sauvegarde et restauration par accès TFTP</td>
</tr>
<tr>
<td><strong>Configuration</strong></td>
<td>fichier de configuration au format binaire pour une installation système rapide</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tab-v1"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>ORDER INFORMATION</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="15%">P/N</th>
<th width="15%">Model name</th>
<th width="70%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-452-DNV</span></td>
<td>IES-2208CA-DNV*</td>
<td>8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-sea rounded">DNV Type Approval*</span></td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1048-24FS</td>
<td>24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1024-24F</td>
<td>24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1240-48S</td>
<td>48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1120-48F</td>
<td>48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – Mini GBIC (SFP)</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="40%">Description</th>
<th width="10%">Model name</th>
<th width="40%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>8330-162</td>
<td>MINI GBIC 1000SX (LC/0.5km) Transceiver</td>
<td>8330-188</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-163</td>
<td>MINI GBIC 1000SX2 (LC/2km) Transceiver</td>
<td>8330-189</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-165</td>
<td>MINI GBIC 1000LX (LC/10km) Transceiver</td>
<td>8330-186</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8340-0591</td>
<td>MINI GBIC 1000LHX (LC/40km) Transceiver</td>
<td>8330-187</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-166</td>
<td>MINI GBIC 1000XD (LC/50km) Transceiver</td>
<td>8330-180</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-169</td>
<td>MINI GBIC 1000XD (LC/60km) Transceiver</td>
<td>8330-182</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-167</td>
<td>MINI GBIC 1000ZX (LC/80km) Transceiver</td>
<td>8330-181</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-170</td>
<td>MINI GBIC 1000EZX (120km) Transceiver</td>
<td>8330-183</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-060</td>
<td>100Base FX 2KM, Multi-mode, LC Transceiver</td>
<td>8330-184</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1490)</td>
</tr>
<tr>
<td>8330-065</td>
<td>100Base FX 5KM, Multi-mode, LC Transceiver</td>
<td>8330-185</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-061</td>
<td>100Base LX 30KM, Single-mode, LC Transceiver</td>
<td>8330-168</td>
<td>MINI GBIC 1000T (100m) Transceiver</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Formation disponible sur demande</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="/wp-content/uploads/sites/3/2017/08/D-IES-2208CA-DNV.pdf" target="_blank" rel="noopener noreferrer">Brochure</a></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/ies-2208ca-dnv/">IES-2208CA-DNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IPGS-3008</title>
		<link>https://www.atevatech.net/produit/ipgs-3008/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipgs-3008</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 18 Jul 2021 08:18:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=30359</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Switch Lantech : IPGS-3008</h2>
<h2>8x 10/100/1000TX PoE at/af administrable L2+, anneau G.8032, modèle 12V en option</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul class="list-unstyled">
<li>PoE IEEE802.at/af, 30W par port</li>
<li>Gestion des ports PoE, détection et planification</li>
<li>Fonctions de redondance en anneau suivant norme ITU G.8032, cicatrisation de l&#8217;anneau &lt;20 ms</li>
<li>Fonctions d&#8217;administration avancées : LCAP, IGMP v3, QinQ</li>
<li>Accès sécurisé : chiffrement SSH/SSL, 802.1X/Radius, https</li>
<li>Double entrées alimentation, version 12V (9.5V à 57 Vdc) ou (44V à 57 Vdc) pour la version 48V</li>
</ul>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecb6dbc-e4f75496-5562"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b436dbc-e4f75496-5562"><span class="vc_tta-title-text">Fonction</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1489133547310-939ec51d-aa6e5496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1489133547310-939ec51d-aa6e5496-5562"><span class="vc_tta-title-text">Détails Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320782574-3b588c5e-ffd46dbc-e4f75496-5562"><span class="vc_tta-title-text">Références</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320754302-7b727c18-3cf06dbc-e4f75496-5562"><span class="vc_tta-title-text">Téléchargement</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320811737-cd23c365-07206dbc-e4f75496-5562"><span class="vc_tta-title-text">Dimensions</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><span style="color: #000000;">Le switch LANTECH IPGS-3008 est un switch puissant, à très haute performance L2+, port Gigabit avec 8 10/100/1000T w/8 PoE 802.3af/at, fournissant une rapidité et une sécurité accrue pour le déploiement d&#8217;agrégation de lien. Dans le cas d’utilisation en anneau ITU G,8032, il permet de permuter de direction en moins de 20ms, pour un simple anneau. Administration rapide et facile du QoS, VLAN, GVRP, Sécurité avancée pour SSH/SSL, TACACS+, Ingress/Egress ACL L2/L3, IGMPv1/v2/v3/Router port, DHCP server/relay, « Jumbo frames » ( largement utilisé pour les réseaux moyen et large..) Il support également le protocole « Cisco Discovery » (CDP) et LLDP, afin d’afficher une topology L2 map.</span></p>
<p>&nbsp;</p>
<p><b>PoE AT/AF avec débit jusqu’à 8 Gigabit, détection et programmation du PoE</b></p>
<p>Le switch LANTECH IPGS-3008 supporte une programmation avancée de la fonction PoE pour la détection et la programmation. La détection PoE peut savoir si l’appareil PD ( Powered Device) est bloqué et permet ainsi un redémarrage. La programmation PoE permet d’alimenter en energie, l’appareil selon un timing déterminé. Chaque port PoE, permet d’être dans l’état « ON /OFF », permet de déterminer la puissance délivré à l’appareil PD. ( Watt, Température, courant, Voltage) Affichage par WebGUI</p>
<p><b>Protection de boucle : Re-alimentation en energie si la boucle est rompue, Alerte par email, trap ou SMS</b></p>
<p>Le switch IPGS-3008 possède d’autres fonctionalitées pour une stabilité accrue du réseau TCP/IP. Si le l’anneau est mal cablé ou défecteux, le switch IPGS-3008 indique son état via une LED et envoie un email, trap ou un SMS. Il se reconnecte utomatiquement en cas de coupure de courant. Le Status vous est envoyé par SMS, quand tous les switches sont ré-alimentés. La protéction de boucle, peut aussi éviter les débordements de « broadcast », si un switch est inséré dans la boucle.</p>
<p><strong><em>User friendly UI; Auto topology drawing*; DMI for dB value</em></strong><br />
The user friendly UI, innovative Auto topology drawing* and topology demo makes IPGS-3008 much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.</p>
<p><strong><em>Enhanced G.8032 Ring &lt; 20ms covering multicast packets for single ring recovery; Enhanced*/basic/auto*/train*mode; MSTP/RSTP</em></strong><br />
Lantech IPGS-3008 features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring*), train ring*, basic ring by easy setup than others. The innovative auto-Ring* configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8 MSTI.</p>
<p><strong><em>DHCP server / client ; DHCP option 82 relay, port based*/Mac based DHCP*; DHCP Option 66*</em></strong><br />
It supports the standard DHCP server/client as well as DHCP option 82 relay. The port based DHCP* distribution can offer the same IP address on port base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The DHCP Option 82 server* offers the convenience of policy setting on the switch. Mac based DHCP server* function binds a fixed IP address and a client Mac address to include dumb switches in DHCP network. It also supports DHCP Option 66*.</p>
<p><strong><em>QoS by VLAN* for legacy device</em></strong><br />
QoS by VLAN* can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p><strong><em>QinQ*, QoS QinQ* and GVRP* supported</em></strong><br />
It supports the QinQ, QoS QinQ, GVRP for large VLAN segmentation.</p>
<p><strong><em>IGMPv3,GMRP*, router port, static multicast forwarding and multicast Ring protection</em></strong><br />
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP*, router port and static multicast forwarding binding by ports for video surveillance application.</p>
<p><strong><em>Exported configuration text file; Factory reset button; CPU watchdog</em></strong><br />
The configuration file of Lantech IPGS-3008 can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. Factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p><strong><em>N-key** for back up, restore configuration and upgrade firmware </em></strong><br />
With N-key**, the configuration file can be mass auto backup, editable restored and auto upgrade firmware for easy maintenance.</p>
<p><strong><em>Relay alarm and email/trap/SMS alerting</em></strong><br />
Featured with relay contact alarm function, the IPGS-3008 is able to connect with alarm system in case of power failure and port disconnection. In case of such event, it will send out email, SMS, trap alerting to predefined users.</p>
<p><strong><em>Dual 12V~48V input with boost technology to 54V PoE output for 12V model, PoE budget 80W</em></strong><br />
Lantech IPGS-3008-12V is designed with dual input power at 9.5V~57VDC while IPGS-3008-48V allows with 44~57VDC input. The PoE budget for 12V input is 80W and for 24V input is 120W.</p>
<p><strong><em>High reliability and extended working temperature</em></strong><br />
Lantech IPGS-3008 provides ±2000V EFT/SURGE and ±6000V contact ESD protection, which can reduce unstable situation caused by power line and Ethernet. It has high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.<br />
The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Fonction</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div align="right">
<div id="tabs-caracteristique" class="ui-tabs-panel ui-widget-content ui-corner-bottom">
<ul>
<li style="text-align: left;">8 ports cuivre 10/100/1000TX, switch administrable de niveau 2+</li>
<li style="text-align: left;">8 ports injecteurs PoE IEEE802.3at/af, puiisance fournie par port actif : jusqu&#8217;à 30W@54Vin; 15W @48Vin</li>
<li style="text-align: left;">Gamme d&#8217;entrée 9.5V à 57 Vdc pour le modèle 12V, puissance PoE disponible 80W avec une entrée 12V, 120W avec 24V en entrée</li>
<li style="text-align: left;">Gamme d&#8217;entrée 45V à 57 Vdc pour le modèle 48V, puissance PoE disponible 240W</li>
<li style="text-align: left;">taux de commutation: 16 Gbps</li>
<li style="text-align: left;">table d&#8217;adresses MAC 16K</li>
<li style="text-align: left;">trame jumbo 10 Ko pour l&#8217;ensemble des ports</li>
<li style="text-align: left;">protocole standard de gestion d&#8217;anneau ITU G.8032, temps de cicatrisation inférieur à 20 ms pour une toplogie en anneau simple</li>
<li style="text-align: left;">entrée alimentation protégée contre les transitoires en tension, jusqu&#8217;à 2000 Vdc</li>
<li style="text-align: left;">port Ethernet protégé contre les décharges électro-statiques, supporte jusqu&#8217;à 6000 Vdc</li>
<li style="text-align: left;">horloge temps réel intégrée</li>
<li style="text-align: left;">classe de service (CoS) 802.1p, 8 files d&#8217;attente par port</li>
<li style="text-align: left;">IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP</li>
<li style="text-align: left;">Port-Based VLAN, IEEE 802.1Q Tag VLAN, GVRP, Q-in-Q, MVR</li>
<li style="text-align: left;">supporte 802.1ab LLDP, Cisco CDP</li>
<li style="text-align: left;">DHCP Serveur/Client/Option 82</li>
<li style="text-align: left;">mise à jour du microcode via un accès TFTP/HTTPS. Micro-code en redondance pour revenir en mode par défaut usine en cas de défaut de la mise à jour</li>
<li style="text-align: left;">journal d&#8217;événements système, e-mail d&#8217;alertes via serveur SMTP, via SMS, trap SNMP en cas de défauts, RMON (Remote Monitoring)</li>
<li style="text-align: left;">fonctions de sécurité:</li>
<li style="text-align: left;">
<div align="left">
<ul class="style109">
<li class="style99">sécurité au niveau du port: entrée /fltrage adresse MAC</li>
<li class="style99">sécurité au niveau de l&#8217;IP</li>
<li class="style99">sécurité au niveau de l&#8217;authentification: IEEE802.1x/RADIUS</li>
<li class="style99">SSH / SSL</li>
<li class="style99">Validation/Dévalidation Web MMI via Console/Telnet</li>
</ul>
</div>
</li>
<li style="text-align: left;">IGMP v3 et Query pour les applications multimédia</li>
<li style="text-align: left;">supporte la fonction le routage IGMP dynamique pour les caméras IP non IGMP</li>
<li style="text-align: left;">bouton reset pour retour en configuration usine</li>
<li style="text-align: left;">watchdog intégré</li>
<li style="text-align: left;">fonction de surveillance et d&#8217;alertes (Trap SNMP) de l&#8217;environment de fonctionnment du switch (température, niveau de tension, charge en courant)</li>
</ul>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1489133547310-939ec51d-aa6e5496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1489133547310-939ec51d-aa6e5496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails Techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h2></h2>
<table border="1" width="540" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="2"><strong>Normes standards</strong></td>
<td>IEEE802.3 10Base-T Ethernet<br />
IEEE802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z fibre Gigabit<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.1x Authentification (Radius)<br />
IEEE802.1ab LLDP<br />
IEEE 802.3az Efficient Energy Ethernet<br />
IEEE802.3at/af Power over Ethernet</td>
</tr>
<tr>
<td colspan="2"><strong>Capacité de commutation<br />
</strong></td>
<td>16 Gbps</td>
</tr>
<tr>
<td colspan="2"><strong>Unité Centrale</strong></td>
<td>Marwell 1600 MHz, 512 Mo de RAM, 128 Mo de mémoire Flash</td>
</tr>
<tr>
<td colspan="2"><strong>Taux de transfert</strong></td>
<td>Ethernet: 14 880 pps par port<br />
Fast Ethernet: 148 800 pps par port<br />
Gigabit Ethernet: 1,488,000 pps par port</td>
</tr>
<tr>
<td colspan="2"><strong>Table d&#8217;adresses MAC</strong></td>
<td>Capacité 16K</td>
</tr>
<tr>
<td colspan="2"><strong>Trame Jumbo</strong></td>
<td>10240 octets pour l&#8217;ensemble des ports</td>
</tr>
<tr>
<td colspan="2"><strong>Connectique</strong></td>
<td>10/100/1000TX: 8x ports RJ-45 avec fonction auto MDI/MDI-X<br />
Console d&#8217;administration : RS-232 connecteur type RJ-45<br />
Alimentation et relais : bornier à vis 6 points</td>
</tr>
<tr>
<td colspan="2"><strong>Câble réseau</strong></td>
<td>10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td colspan="2"><strong>Protocole</strong></td>
<td>CSMA/CD</td>
</tr>
<tr>
<td colspan="2"><strong>Surveillance des conditions d&#8217;environment **</strong></td>
<td>Surveillance du niveau de tension et de la température, envoi d&#8217;une notification de défaut</td>
</tr>
<tr>
<td colspan="2"><strong>Température de fonctionnement</strong></td>
<td>-20°C ~ 60°C (modèle standard)<br />
-40°C ~ 75°C (modèle -E)</td>
</tr>
<tr>
<td colspan="2"><strong>Température de stockage</strong></td>
<td>-40°C ~ 85°C</td>
</tr>
<tr>
<td colspan="2"><strong>Alimentation</strong></td>
<td>9.5 Vdc à 57 Vdc pour la version 12 V<br />
44 Vdc à 57 Vdc pour la version 48 V<br />
alimentation avec entrées redondantes<em><br />
</em></td>
</tr>
<tr>
<td colspan="2"><strong>Budget PoE</strong></td>
<td>240W pour une entrée de 44 à 57Vdc (modèle 48V)<br />
80W pour une entrée 12V; 120W pour une entrée 24V(modèle 12V)</td>
</tr>
<tr>
<td colspan="2"><strong>Puissance consommée</strong></td>
<td>10 W</td>
</tr>
<tr>
<td colspan="2"><strong>Dimensions</strong></td>
<td>43 (W) x 105 (D) x 152 (H) mm</td>
</tr>
<tr>
<td colspan="2"><strong>Indice de protection</strong></td>
<td>IP 30</td>
</tr>
<tr>
<td colspan="2"><strong>CEM</strong></td>
<td>FCC Part 15 Class A,<br />
IEC/EN61000-6-2<br />
CE EN55032 Class A<br />
CE EN55024: CE EN61000-4-2 (ESD) Level 3<br />
CE EN61000-4-3 (RS) Level 3<br />
CE EN61000-4-4 (EFT) Level 3<br />
CE EN61000-4-5 ED3 (Surge) Level 3<br />
CE EN61000-4-6 (CS) Level 3<br />
CE EN61000-4-8 (Magnetic field) Level 3</td>
</tr>
<tr>
<td colspan="2"><strong>Chocs et Vibrations</strong></td>
<td>IEC60068-2-32 (chute libre)<br />
IEC60068-2-27 (choc)<br />
IEC60068-2-6 (vibration)</td>
</tr>
<tr>
<td colspan="2"><strong>Fixation</strong></td>
<td>Rail DIN, en option kit de montage sur panneau</td>
</tr>
</tbody>
</table>
<h3 class="panel-title"></h3>
<h2>Caractéristiques logicielles IPGS-3008</h2>
<h3 class="panel-title"></h3>
<table border="1" width="560" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Modes d&#8217;administration</strong></td>
<td>SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td><strong>Support MIB<br />
</strong></td>
<td>RFC 1215 Traps MIB*,<br />
RFC 1213 MIBII<br />
RFC 1158 MIBII<br />
RFC 1157 SNMP MIB*,<br />
RFC 1493 Bridge MIB*,<br />
RFC 1573 IF MIB<br />
RFC 2674 VLAN MIB,<br />
Partial RFC 1757 RMON,<br />
RFC 2674 Q-Bridge MIB*; Bridge MIB*,<br />
LLDP MIB*<br />
RSTP MIB*<br />
Private MIB</td>
</tr>
<tr>
<td><strong>ITU G.8032</strong></td>
<td>Version ITU G.8032 v2/2012, autocicatrisation en moins de 20 ms, compatible avec les switches disposant du protocole ITU G.8032</td>
</tr>
<tr>
<td><strong>Port Trunk avec LACP</strong></td>
<td>LACP Port Trunk: 8 groupes/Maximum 10 membres par tronc</td>
</tr>
<tr>
<td><strong>LLDP</strong></td>
<td>Permet au switch de communiquer son identification et caractéristiques</td>
</tr>
<tr>
<td><strong>CDP</strong></td>
<td>Protocole de découverte CISCO pour le mappage réseau</td>
</tr>
<tr>
<td><strong>VLAN</strong></td>
<td>VLAN par port<br />
VLAN à balisage 802.1Q (256 entrées)/ VLAN ID ( VLAN ID de 1 à 4096)<br />
GVRP (256 Groupes)</td>
</tr>
<tr>
<td><strong>IPv6/4</strong></td>
<td>Supporté</td>
</tr>
<tr>
<td><strong>Gestion de boucle</strong></td>
<td>Spanning tree 802.1d et Rapid Spanning Tree 802.1w, Multiple Spanning Tree IEEE802.1s</td>
</tr>
<tr>
<td><strong>Qualité de service<br />
</strong></td>
<td>QoS, service par port, balisage et IPV4, IPv4 Different Service</td>
</tr>
<tr>
<td><strong>Classe de Service<br />
</strong></td>
<td>802.1p, file d&#8217;attente à 8 niveaux de priorité par port</td>
</tr>
<tr>
<td><strong>Mise en miroir de ports<br />
</strong></td>
<td>3 modes : RX, TX et RX/TX</td>
</tr>
<tr>
<td><strong>IGMP</strong></td>
<td>IGMP snooping v1,v2, v3<br />
diffusion de groupe (256) et requête IGMP</td>
</tr>
<tr>
<td><strong>Sécurité IP</strong></td>
<td>Table de 10 adresses IP autorisées à administrer le switch</td>
</tr>
<tr>
<td><strong>Authentification</strong></td>
<td>IEEE802.1x, RADIUS</td>
</tr>
<tr>
<td><strong>Sécurité du réseau</strong></td>
<td>Accès suivant protocole 802.1x et serveur RADIUS<br />
Association adresses IP et MAC sur les ports (MAC-Poort binding)<br />
Chiffrement SSL et SSH<br />
Liste de contrôle d&#8217;accès (ACL L2/L3)<br />
Interface de gestion WEN accessible en HTTPS</td>
</tr>
<tr>
<td><strong>Filtrage Multidiffusion et IGMP</strong></td>
<td><em>Dynamic:</em><br />
<em>Support IGMP snooping v1, v2,v3 and MLD snooping v1. </em><br />
<em>Support 256 multicast groups</em><br />
<em>Support IGMP and MLD query</em><br />
<em>Support Dynamic IGMP router port for non-IGMP cameria</em><br />
<em>Static: </em><br />
<em>Support 256 static multicast groups</em></td>
</tr>
<tr>
<td><strong>Contrôle de la bande passante</strong></td>
<td>Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td><strong>Journal système<br />
</strong></td>
<td>Enregistrement de l&#8217;activité du système en local et sur serveur distant<em><br />
</em></td>
</tr>
<tr>
<td><strong>Envoi d&#8217;alertes</strong></td>
<td>Serveur SMTP, 8 comptes e-mails, SMS</td>
</tr>
<tr>
<td><strong>Serveur de temps<br />
</strong></td>
<td>Synchronisation avec un serveur de temps sur Internet</td>
</tr>
<tr>
<td><strong>Sortie relais<br />
</strong></td>
<td>sur défauts de connection et alimentation</td>
</tr>
<tr>
<td><strong>Alerte SNMP</strong></td>
<td>1. démarrage à froid<br />
2. perte de lien<br />
3. défaut d&#8217;authentification<br />
4. modification de la toplogie de l&#8217;anneau<br />
5. défaut d&#8217;alimentation<br />
6. en option, conditions internes d&#8217;environment anormales</td>
</tr>
<tr>
<td><strong>DHCP</strong></td>
<td>Client, serveur, relais DHCP option 82</td>
</tr>
<tr>
<td><strong>DNS</strong></td>
<td>Fonction DNS client, supporte un serveur DNS primaire et secondaire</td>
</tr>
<tr>
<td><strong>Mise à jour firmware</strong></td>
<td>Transfert de fichier TFTP, sauvegarde et restauration de fichier par TFTP, par HTTP</td>
</tr>
<tr>
<td><strong>Mode de configuration</strong></td>
<td>Fichier au format TX</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div class="col-md-6"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Références</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<thead>
<tr>
<th width="10%">P/N</th>
<th width="15%">Model name</th>
<th width="75%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-986</span></td>
<td>IPGS-3008-48V</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input; -20°C to 60°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-987</span></td>
<td>IPGS-3008-48V-E</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-988</span></td>
<td>IPGS-3008-12V</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; <span class="text-highlights text-highlights-red rounded">dual 9.5V~57VDC input</span>; -20°C to 60°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-989</span></td>
<td>IPGS-3008-12V-E</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; <span class="text-highlights text-highlights-red rounded">dual 9.5V~57VDC input</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8850-100</span></td>
<td>N-key Configurator</td>
<td>RJ45 connector dongle for firmware upgrade, auto/editable configuration backup and restoration; -20°C to 60C</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES &#8211; DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>NDR-480 Series</td>
<td>480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>NDR-240 Series</td>
<td>240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>NDR-120 Series</td>
<td>120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)</td>
</tr>
<tr>
<td>NDR-75 Series</td>
<td>75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/D-IPGS-3008.pdf" target="_blank" rel="noopener noreferrer">Datasheet </a></p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Dimensions</span></a></h4></div><div class="vc_tta-panel-body">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/D-IPGS-3008.png" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/ipgs-3008/">IPGS-3008</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FINISAR &#8211; FTLF8524P2BNV</title>
		<link>https://www.atevatech.net/produit/finisar-ftlf8524p2bnv-3/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=finisar-ftlf8524p2bnv-3</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 06 Jan 2021 05:49:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=28901</guid>

					<description><![CDATA[<p>&#160;</p>
<div id="sconnect-is-installed" style="display: none">2.15.0.0</div>
<div id="sconnect-is-installed" style="display: none">2.15.0.0</div>
The post <a href="https://www.atevatech.net/produit/finisar-ftlf8524p2bnv-3/">FINISAR – FTLF8524P2BNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Module SFP Finisar’s FTLF8524P2xNV</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Finisar 500m Duplex SFP Transceiver | FTLF8524P2BNV</h2>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p style="text-align: justify"><strong>Descriptif produit</strong></p>
<p style="text-align: justify">Rédiger un descriptif produit intégrant le mot ou groupe de mots-clés à référencer d&#8217;au minimum 50 mots. Le mot-clé ou le groupe de mot-clés devrat être répété au moins 2 ou 3 fois dans ce paragraphe.<br />
Les photos disposées à gauche sont au format 4/3 de préférence, il est possible d&#8217;en changer le format en indiquant la résolution. Il est très important de préciser un nom de fichier compréhensible par google (mot clé) et de le répéter dans l&#8217;attribut &#8220;alt&#8221;.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Technical details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Finisar 500m Duplex SFP Transceiver | FTLF8524P2BNV</h2>
<p>The Finisar FTLF8524P2BNV 1000BASE-SX Ethernet transceiver is a Duplex SFP transceiver for optical communications, rated for distances up to 500m and a maximum bandwidth of 4.25Gbps. The FTLF8524P2BNV transceiver operates at 850nm wavelength. 4Gb/s 850nm FC -20 to 85C, Rate Select SFP. Finisar FTLF8524P2xNV SFP transceivers are compatible with the small form factor pluggable MSA.. Note: Due to manufacturer restrictions, Finisar FTLF8524P2BNV is a non-cancellable &amp; non-returnable product. Please call to confirm stock. This product is manufactured by Finisar USA, ships directly from Finisar and is covered by full manufacturer warranty within the USA. For most up-to-date specifications, refer to datasheets on Finisar website. Images are for illustrative purposes only.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>Finisar 1000BASE-SX Ethernet SFP</li>
<li>Up-to 500m over MMF @ 4.25Gbps</li>
<li>850nm Duplex SFP Transceiver</li>
<li>-10º &#8211; 85º Operating Case Temperature</li>
<li>SFF-8724 Digital optical monitoring</li>
<li>Hot-swappable for SFP LC ports</li>
<li>Finisar Standard 1 Year Warranty</li>
<li>Metal enclosure, for lower EMI</li>
<li>SFP MSA / IEEE Std 802.3</li>
<li>Finisar FTLF8524P2BNV is RoHS complian</li>
<li>1000BASE-SX Ethernet</li>
<li>1.063/2.125/4.25 Gb/s FC</li>
<li>Rate selectable version</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: FINISAR FTLF8524P2BNV</h4>
<p>SFP transceiver specifications.</p>
</div>
<p><a class="dl-link" href="/ftp/SFP/FTLF8524P2BNV_datasheet.pdf" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e87331d7-2779" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Ref: FTLF8524P2BNV</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
<div id="sconnect-is-installed" style="display: none">2.15.0.0</div>
<div id="sconnect-is-installed" style="display: none">2.15.0.0</div>
</div>The post <a href="https://www.atevatech.net/produit/finisar-ftlf8524p2bnv-3/">FINISAR – FTLF8524P2BNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
