<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PoE Switch | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/product-tag/poe-switch/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Thu, 26 Feb 2026 06:12:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>PoE Switch | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IPGS-3408GSFP</title>
		<link>https://www.atevatech.net/produit/ipgs-3408gsfp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipgs-3408gsfp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 10 May 2023 16:24:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=35192</guid>

					<description><![CDATA[<h3>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h3>
The post <a href="https://www.atevatech.net/produit/ipgs-3408gsfp/">IPGS-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h1>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="800" height="471" src="https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E.png" class="vc_single_image-img attachment-full" alt="IPES-3408GSFP-E" title="IPGS-3408GSFP-E" srcset="https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E.png 800w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-400x236.png 400w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-300x177.png 300w, https://www.atevatech.net/wp-content/uploads/2023/05/IPGS-3408GSFP-E-768x452.png 768w" sizes="(max-width: 800px) 100vw, 800px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>PoE Managed switch : 8* 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032</h2>
<div class="col-md-12">
<ul class="list-unstyled">
<li><i class="fa fa-check color-green"></i> Support IEEE802.3at/af up to 30W per port</li>
<li><i class="fa fa-check color-green"></i> PoE management incl. Detection and Scheduling</li>
<li><i class="fa fa-check color-green"></i> Enhanced G.8032 ring protection &lt; 20ms for single ring. Supports auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP; support MRP ring</li>
<li><i class="fa fa-check color-green"></i> Miss-wiring avoidance &amp; Node failure protection</li>
<li><i class="fa fa-check color-green"></i> User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI</li>
<li><i class="fa fa-check color-green"></i> Support LACP link aggregation, IGMP v3/router port, MLD snooping, DHCP server &amp; DHCP Option82; DHCP Snooping, Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH v2/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3,TACACS+**, QinQ</li>
<li><i class="fa fa-check color-green"></i> Protocol based VLAN; IPv4 Subnet based VLAN</li>
<li><i class="fa fa-check color-green"></i> Environmental Monitoring for temp., voltage &amp; current**</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-35205" src="https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-300x80.png" alt="" width="442" height="118" srcset="https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-300x80.png 300w, https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624-400x107.png 400w, https://www.atevatech.net/wp-content/uploads/2023/05/DeepinScreenshot_select-area_20230510183624.png 521w" sizes="(max-width: 442px) 100vw, 442px" /></p>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview266a-758d"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Technical Data</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d"><span class="vc_tta-title-text">Misc</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Lantech IPGS-3408GSFP is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 4 1000M SFP w/8 PoE 802.3af/at ports which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode , multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) for Ciscoworks to detect the switch info and show on L2 map topology.</p>
<p>&nbsp;</p>
<p><strong><em>Up to 8 PoE at/af ports w/advanced PoE management </em></strong><br />
Compliant with 802.3af/at standard, the Lantech IPGS-3408GSFP is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPGS-3408GSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.</p>
<p>&nbsp;</p>
<p><strong><em>Miss-wiring avoidance, Loop protection, Node failure protection</em></strong><br />
The IPGS-3408GSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-3408GSFP is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.</p>
<p>&nbsp;</p>
<p><strong><em>DHCP option 82 &amp; Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server</em></strong><br />
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.</p>
<p>&nbsp;</p>
<p><strong><em>User friendly GUI, Auto topology drawing</em></strong><br />
The user friendly UI, innovative auto topology drawing and topology demo makes IPGS-3408GSFP much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.</p>
<p>&nbsp;</p>
<p><strong><em>Enhanced G.8032 ring, 16 MSTI MSTP; MRP ring</em></strong><br />
Lantech IPGS-3408GSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.</p>
<p>&nbsp;</p>
<p>MRP (Media Redundancy Protocol) can be supported for industrial automation networks.</p>
<p>&nbsp;</p>
<p><strong><em>Editable configuration file</em></strong><br />
The configuration file of Lantech IPGS-3408GSFP can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p>&nbsp;</p>
<p><strong><em>QoS by VLAN for legacy device</em></strong><br />
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p>&nbsp;</p>
<p><strong><em>QinQ, QoS and GVRP supported</em></strong><br />
It supports the QinQ, QoS, GVRP for large VLAN segmentation.</p>
<p>&nbsp;</p>
<p><strong><em>802.1X security by MAC address</em></strong><br />
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host&#8217;s source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.</p>
<p>&nbsp;</p>
<p><strong><em>IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection</em></strong><br />
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.</p>
<p>&nbsp;</p>
<p><strong><em>Event log &amp; message; 2 DI + 2DO</em></strong><br />
In case of event, the IPGS-3408GSFP is able to send an email to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO when disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.</p>
<p>&nbsp;</p>
<p><strong><em>Optional environmental monitoring for switch inside information (-M model) </em></strong><br />
The optional environmental monitoring can detect switch overall temperature, voltage, total PoE load and current where can send the SNMP traps, email when abnormal.</p>
<p>&nbsp;</p>
<p><strong><em>Wide range dual DC powered input with galvanic isolation; Relay contact alarm, High ESD protection</em></strong><br />
The Lantech IPGS-3408GSFP is designed with dual power supply at 24/48VDC or single power supply at 90~305VAC/120~430VDC. Featured with relay contact alarm function, the IPGS-3408GSFP is able to connect with alarm system in case of power failure. The IPGS-3408GSFP also provides ±2000V EFT/SURGE and ±4000 VDC (Contact) / ±8000 VDC (Air) Ethernet ESD protection, which can reduce unstable situation caused by power line and Ethernet.</p>
<p>&nbsp;</p>
<p><strong><em>Industrial hardened design for extended temperature operation </em></strong><br />
Lantech IPGS-3408GSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.</p>
<p>&nbsp;</p>
<p>The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Data</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>FEATURES</h4>
<ul>
<li>8 10/100/1000T + 4 1000M SFP w/8 PoE 802.3af/at ports (Total 12 Ports Switch)</li>
<li>Embedded 8 PoE ports IEEE802.3af/at function to feed power up to 30W@54V; 15W @ 48V per port for active operation</li>
<li>PoE voltage boost from 12V to 54V (12V model)</li>
<li>PoE management including PoE detection and scheduling for PD (power devices)</li>
<li>Back-plane (Switching Fabric): 24Gbps, non-blocking</li>
<li>16K MAC address table</li>
<li>DDM to support SFP diagnostic function***
<ul>
<li>Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance</li>
</ul>
</li>
<li>10KB Jumbo frame on all ports</li>
<li>User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting</li>
<li>Enhanced G.8032 Ring protection in 20ms for single ring
<ul>
<li>Support various ring/chain topologies, including dynamic coupling ring</li>
<li>Enhanced G.8032 ring configuration with ease</li>
<li>Auto ring configuration(auto mode) for single ring</li>
<li>Ring covers multicast on different ports</li>
</ul>
</li>
<li>Provides EFT protection ±2000 VDC for power line.</li>
<li>Supports ±4000 VDC (Contact) and ±8000 VDC (Air) Ethernet ESD protection</li>
<li>LACP load balancing to distribute the load*</li>
<li>Built-in RTC (Real Time Clock) to keep track of time</li>
<li>Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority</li>
<li>IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy</li>
<li>4K 802.1Q VLAN, Port based VLAN, GVRP, QinQ*</li>
<li>Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console</li>
<li>DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server; Port based DHCP server; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server</li>
<li>Mac based DHCP server to assign IP address</li>
<li>MLD Snooping for IPv6 Multicast stream</li>
<li>Bandwidth Control
<ul>
<li>Ingress packet filter and egress rate limit</li>
<li>Broadcast/multicast packet filter control</li>
</ul>
</li>
<li>Relay alarm output system events</li>
<li>Miss-wiring avoidance
<ul>
<li>LED indicator</li>
<li>Email or traps notification</li>
</ul>
</li>
<li>Node failure protection
<ul>
<li>Ensure the switches in a ring to survive after power breakout is back</li>
<li>The status can be shown in NMS when each switch is back</li>
</ul>
</li>
<li>TFTP/HTTP firmware upgrade</li>
<li>System Event Log and SNMP Trap for alarm support; 32 RMON counters</li>
<li>Security
<ul>
<li>SSL/SSH v2/INGRESS/EGRESS ACL L2/L3</li>
<li>MAC address table: MAC address entries/Filter/MAC-Port binding</li>
<li>IP Security: IP address security management to prevent unauthorized intruder.</li>
<li>Management access control with priority</li>
<li>Login Security: IEEE802.1X/RADIUS</li>
<li>HTTPS for secure access to the web interface</li>
<li>TACACS+**</li>
</ul>
</li>
<li>Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application</li>
<li>IGMP router port to assign query in ring and for reversed multicast video flow</li>
<li>Multicast VLAN registration* for metro video</li>
<li>IGMPv1,v2,v3 with Query mode for multi media; GMRP</li>
<li>Factory reset button to restore setting to factory default</li>
<li>Watchdog design to auto reboot switch CPU is found dead</li>
<li>Diagnostic including Ping / DDM information</li>
<li>Optional environmental monitoring for system input voltage, current, ambient temperature</li>
<li>Supports DIDO (Digital Input/Digital Output)</li>
<li>Fanless design, no moving parts</li>
<li>IP30 metal housing with DIN rail and Wall-mount** design</li>
<li>Auto Provision to verify switch firmware with the latest or certain version</li>
</ul>
<div align="right">
<h6>*Future Release</h6>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: IPGS-3408GSFP</h4>
<p>Technical specifications and features.</p>
</div>
<p><a class="dl-link" href="https://atevatech.aztgrp.net:8080/index.php/s/YSxncryNjAABT88" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-611</span></td>
<td>IPGS-3408GSFP-48V</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-612</span></td>
<td>IPGS-3408GSFP-48V-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-613</span></td>
<td>IPGS-3408GSFP-48V-M</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-614</span></td>
<td>IPGS-3408GSFP-48V-M-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 44~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-617</span></td>
<td>IPGS-3408GSFP-12V</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-618</span></td>
<td>IPGS-3408GSFP-12V-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-6171</span></td>
<td>IPGS-3408GSFP-12V-M</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-6181</span></td>
<td>IPGS-3408GSFP-12V-M-E</td>
<td>8 10/100/1000T PoE at/af up to 30W + 4 1000M SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Dual 9.5~56VDC</span></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb266a-758d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Misc</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4></h4>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-cogs"></i> Hardware Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Standards</td>
<td valign="top">IEEE 802.3 10Base-T Ethernet<br />
IEEE 802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z Gigabit fiber<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1s Multiple Spanning Tree<br />
IEEE 802.3ad Link Aggregation Control Protocol (LACP)<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE 802.1X User Authentication (Radius)<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.3at/af Power over Ethernet</td>
</tr>
<tr>
<td valign="top">Switch Architecture</td>
<td valign="top">Back-plane (Switching Fabric): 24Gbps</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port<br />
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port</td>
</tr>
<tr>
<td valign="top">CPU</td>
<td valign="top">Marvell 800Mhz</td>
</tr>
<tr>
<td valign="top">RAM</td>
<td valign="top">256M Byte</td>
</tr>
<tr>
<td valign="top">Flash</td>
<td valign="top">128M Byte</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Jumbo frame</td>
<td valign="top">10KB on all ports</td>
</tr>
<tr>
<td valign="top">Connectors</td>
<td valign="top">10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function<br />
Mini-GBIC: 4 x 1000 SFP socket with DDM<br />
RS-232 connector: RJ-45 type<br />
Power &amp; P-Fail connector: 1 x 6-pole terminal block<br />
DIDO : 1 x 6-pole terminal block</td>
</tr>
<tr>
<td valign="top">Network Cable</td>
<td valign="top">10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td valign="top">Optical Cable</td>
<td valign="top"><strong>1.25Gbps:</strong><br />
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)<br />
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)<br />
<strong>WDM 1.25Gbps:</strong><br />
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)</td>
</tr>
<tr>
<td valign="top">Protocol</td>
<td valign="top">CSMA/CD</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), RM (Green)<br />
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)</td>
</tr>
<tr>
<td valign="top">DI/DO</td>
<td valign="top">2 Digital Input (DI) :<br />
Level 0: -30~2V / Level 1: 10~30V<br />
Max. input current:8mA<br />
2 Digital Output(DO): Open collector to 40 VDC, 200mA</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% ~ 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-20°C~60°C / -4°F~140°F (Standard model)<br />
-40°C~75°C / -40°F~167°F(-E model)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C~85°C / -40°F~185°F</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">44~56VDC (48V model)<br />
9.5~56VDC (12V model)</td>
</tr>
<tr>
<td valign="top">PoE Budget</td>
<td valign="top">240W for 45~56V input<br />
(55V input is recommended for 802.3at 30W applications)<br />
120W for 24V input<br />
90W for 12V input<br />
Higher PoE budget can be applied upon request. **</td>
</tr>
<tr>
<td valign="top">PoE pin assignment</td>
<td valign="top">RJ-45 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W PoE at/ 15W PoE af.<br />
Positive (VCC+): RJ-45 pin 1,2.<br />
Negative (VCC-): RJ-45 pin 3,6.</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">10W</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Metal case. IP-30,<br />
74 (W) x 105 (D) x 152 (H) mm (Standard model)<br />
74 (W) x 105 (D) x 152 (H) mm (12V model)<br />
96.3 (W) x 135 (D) x 152 (H) mm (-E model)</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">900 g</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">DIN Rail and Wall Mount** Design</td>
</tr>
<tr>
<td valign="top">EMI &amp; EMS</td>
<td valign="top">FCC Class A,<br />
CE EN55032 Class A, CE EN55024 ,<br />
CE EN61000-4-2, CE EN61000-4-3,<br />
CE EN61000-4-4, CE EN61000-4-5,<br />
CE EN61000-4-6, CE EN61000-4-8<br />
CE EN61000-6-2<br />
BS EN55032, BS EN55024,<br />
BS EN61000-4-2, BS EN61000-4-3,<br />
BS EN61000-4-4, BS EN61000-4-5,<br />
BS EN61000-4-6, BS EN61000-4-8</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">IEC60068-2-32 (Free fall),<br />
IEC60068-2-27 (Shock),<br />
IEC60068-2-64 (Vibration)</td>
</tr>
<tr>
<td valign="top">MTBF</td>
<td valign="top">782,391 hours</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title"><i class="fa fa-desktop"></i> Software Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Management</td>
<td valign="top">SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td valign="top">SNMP MIB</td>
<td valign="top">MIB<br />
MIBII<br />
SNMP MIB<br />
Bridge MIB<br />
IF MIB<br />
RMON MIB<br />
Private MIB</td>
</tr>
<tr>
<td valign="top">ITU G.8032</td>
<td valign="top">Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)<br />
Support various ring/chain topologies<br />
Includes dynamic coupling ring<br />
Enhanced G.8032 ring configuration with ease<br />
Ring covers multicast on different ports</td>
</tr>
<tr>
<td valign="top">PoE Management</td>
<td valign="top">
<ol>
<li>PoE Detection to check if PD hangs then restart the PD</li>
<li>PoE Scheduling to On/OFF PD upon routine time table</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Per Port PoE Status</td>
<td valign="top">On/ Off, voltage, current, watts, temperature</td>
</tr>
<tr>
<td valign="top">User friendly UI</td>
<td valign="top">
<ol>
<li>Auto topology drawing</li>
<li>Topology demo</li>
<li>DDM threshold monitoring with dB values***</li>
<li>Complete CLI for professional setting</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Port Trunk with LACP</td>
<td valign="top">LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members</td>
</tr>
<tr>
<td valign="top">LLDP</td>
<td valign="top">Supports LLDP to allow switch to advise its identification and capability on the LAN</td>
</tr>
<tr>
<td valign="top">CDP</td>
<td valign="top">Cisco Discovery Protocol for topology mapping</td>
</tr>
<tr>
<td valign="top">Environmental Monitoring**</td>
<td valign="top">System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models)</td>
</tr>
<tr>
<td valign="top">VLAN</td>
<td valign="top">Port Based VLAN<br />
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096)<br />
GVRP, QinQ, Protocol based VLAN; IPv4 Subnet based VLAN</td>
</tr>
<tr>
<td valign="top">Spanning Tree</td>
<td valign="top">Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree</td>
</tr>
<tr>
<td valign="top">Quality of Service</td>
<td valign="top">The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4</td>
</tr>
<tr>
<td valign="top">Class of Service</td>
<td valign="top">Support IEEE802.1p class of service, per port provides 8 priority queues</td>
</tr>
<tr>
<td valign="top">MLD Snooping</td>
<td valign="top">Support IPv6 Multicast stream</td>
</tr>
<tr>
<td valign="top">Login Security</td>
<td valign="top">Supports IEEE802.1X Authentication/RADIUS</td>
</tr>
<tr>
<td valign="top">Port Mirror</td>
<td valign="top">Support 3 mirroring types: “RX, TX and Both packet”</td>
</tr>
<tr>
<td valign="top">Network Security</td>
<td valign="top">Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.<br />
802.1X access control for port based and MAC based authentication/MAC-Port binding<br />
Management access control with priority<br />
Ingress/Egress ACL L2/L3<br />
SSL/ SSH v2 for Management<br />
HTTPS for secure access to the web interface<br />
TACACS+** for Authentication</td>
</tr>
<tr>
<td valign="top">IGMP</td>
<td valign="top">Support IGMP snooping v1,v2,v3; 1024 multicast groups; IGMP router port ; IGMP query; GMRP</td>
</tr>
<tr>
<td valign="top">Static MAC-Port bridge</td>
<td valign="top">Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application</td>
</tr>
<tr>
<td valign="top">Bandwidth Control</td>
<td valign="top">Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td valign="top">RTC</td>
<td valign="top">Built-in Real Time Clock to keep track of time always</td>
</tr>
<tr>
<td valign="top">Flow Control</td>
<td valign="top">Supports Flow Control for Full-duplex and Back Pressure for Half-duplex</td>
</tr>
<tr>
<td valign="top">System Log</td>
<td valign="top">Supports System log record and remote system log server</td>
</tr>
<tr>
<td valign="top">Relay Alarm</td>
<td valign="top">Provides one relay output for port breakdown, power fail and alarm.<br />
Alarm Relay current carry ability: 1A @ DC24V</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">
<ol>
<li>Miss-wiring avoidance</li>
<li>Node failure protection</li>
<li>Loop protection</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">SNMP Trap</td>
<td valign="top">Up to 10 trap stations; trap types including:</p>
<ol>
<li>Device cold start</li>
<li>Authorization failure</li>
<li>Port link up/link down</li>
<li>DI/DO open/close</li>
<li>Typology change(ITU ring)</li>
<li>PoE ping failure</li>
<li>Power failure</li>
<li>Environmental abnormal**</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">DHCP</td>
<td valign="top">Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server</td>
</tr>
<tr>
<td valign="top">Mac based DHCP Server</td>
<td valign="top">Assign IP address by Mac</td>
</tr>
<tr>
<td valign="top">DNS</td>
<td valign="top">Provide DNS client feature</td>
</tr>
<tr>
<td valign="top">Diagnostic</td>
<td valign="top">Support Ping and DDM information</td>
</tr>
<tr>
<td valign="top">SNTP</td>
<td valign="top">Supports SNTP to synchronize system clock in Internet</td>
</tr>
<tr>
<td valign="top">Firmware Update</td>
<td valign="top">Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade</td>
</tr>
<tr>
<td valign="top">Configuration<br />
upload and download</td>
<td valign="top">Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default</td>
</tr>
<tr>
<td valign="top">IfAlias</td>
<td valign="top">Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface</td>
</tr>
<tr>
<td valign="top">Auto Provision</td>
<td valign="top">To verify switch firmware with the latest or certain version</td>
</tr>
</tbody>
</table>
</div>
</div>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/ipgs-3408gsfp/">IPGS-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
