<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Echolink S7 Compact | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/product-tag/echolink-s7-compact/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Thu, 26 Feb 2026 06:12:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>Echolink S7 Compact | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Echolink S7 Compact: the adaptator for S7 Communication</title>
		<link>https://www.atevatech.net/produit/echolink-s7-compact/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=echolink-s7-compact</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 19 Jul 2023 07:56:51 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=35412</guid>

					<description><![CDATA[<p>Echolink S7 Compact : Compact Profibus/ MPI Adapator,Gateway to access any Simens S7 PLC for programming, configuration. Give an Ethernet connection to your PLC</p>
The post <a href="https://www.atevatech.net/produit/echolink-s7-compact/">Echolink S7 Compact: the adaptator for S7 Communication</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>Echolink S7 Compact</h1>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="150" height="150" src="https://www.atevatech.net/wp-content/uploads/2023/05/not-available-rubber-stamp-seal-vector-150x150.jpg" class="vc_single_image-img attachment-thumbnail" alt="" title="not-available-rubber-stamp-seal-vector" srcset="https://www.atevatech.net/wp-content/uploads/2023/05/not-available-rubber-stamp-seal-vector-150x150.jpg 150w, https://www.atevatech.net/wp-content/uploads/2023/05/not-available-rubber-stamp-seal-vector-300x300.jpg 300w, https://www.atevatech.net/wp-content/uploads/2023/05/not-available-rubber-stamp-seal-vector-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></div>
		</figure>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="225" height="225" src="https://www.atevatech.net/wp-content/uploads/2023/07/EcholinkS7.jpeg" class="vc_single_image-img attachment-full" alt="" title="EcholinkS7" srcset="https://www.atevatech.net/wp-content/uploads/2023/07/EcholinkS7.jpeg 225w, https://www.atevatech.net/wp-content/uploads/2023/07/EcholinkS7-100x100.jpeg 100w, https://www.atevatech.net/wp-content/uploads/2023/07/EcholinkS7-150x150.jpeg 150w" sizes="(max-width: 225px) 100vw, 225px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2 style="text-align: justify"><strong>Echolink S7 Compact  :</strong></h2>
<ul>
<li><span id="page342R_mcid0" class="markedContent">Echolink</span><span id="page342R_mcid1" class="markedContent"></span><span id="page342R_mcid2" class="markedContent"><span dir="ltr" role="presentation"> S7 Compact is an adapter for Communication with Siemens S7 Controllers</span></span></li>
<li><span id="page342R_mcid5" class="markedContent"><span dir="ltr" role="presentation">Integration</span> <span dir="ltr" role="presentation">of</span> <span dir="ltr" role="presentation">S7-200,</span> <span dir="ltr" role="presentation">S7-300</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">S7-400</span> <span dir="ltr" role="presentation">into</span> <span dir="ltr" role="presentation">Ethernet</span> <span dir="ltr" role="presentation">Architectures</span></span></li>
<li><span id="page342R_mcid8" class="markedContent"><span dir="ltr" role="presentation">PLC</span> <span dir="ltr" role="presentation">Programming</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">Communication</span> <span dir="ltr" role="presentation">via</span> <span dir="ltr" role="presentation">Interface</span></span></li>
<li><span id="page342R_mcid11" class="markedContent"><span dir="ltr" role="presentation">Integration</span> <span dir="ltr" role="presentation">into</span> <span dir="ltr" role="presentation">Product</span> <span dir="ltr" role="presentation">Management</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">Visualization</span> <span dir="ltr" role="presentation">Applications </span></span><span id="page342R_mcid12" class="markedContent"><span dir="ltr" role="presentation">echolink</span> <span dir="ltr" role="presentation">S7compact</span></span></li>
<li><span id="page342R_mcid13" class="markedContent"><span dir="ltr" role="presentation">Integration</span> <span dir="ltr" role="presentation">of</span> <span dir="ltr" role="presentation">S7-200,</span> <span dir="ltr" role="presentation">S7-300</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">S7-400</span> <span dir="ltr" role="presentation">into </span></span><span id="page342R_mcid14" class="markedContent"><span dir="ltr" role="presentation">10/100</span> <span dir="ltr" role="presentation">Mbit</span> <span dir="ltr" role="presentation">Ethernet</span> <span dir="ltr" role="presentation">Networks</span></span></li>
<li><span id="page342R_mcid17" class="markedContent"><span dir="ltr" role="presentation">Direct communication with one or several </span></span><span id="page342R_mcid18" class="markedContent"><span dir="ltr" role="presentation">controllers in any kind of TCP network structure</span></span></li>
<li><span id="page342R_mcid21" class="markedContent"><span dir="ltr" role="presentation">Support of up to 16 simultaneous connections </span></span></li>
<li><span id="page342R_mcid24" class="markedContent"><span dir="ltr" role="presentation">Use of standard TCP/IP for communication within </span></span><span id="page342R_mcid25" class="markedContent"><span dir="ltr" role="presentation">plant or company networks and with the Internet</span></span></li>
<li><span id="page342R_mcid28" class="markedContent"><span dir="ltr" role="presentation">Expansion of participants using MPI or PROFIBUS </span></span><span id="page342R_mcid29" class="markedContent"><span dir="ltr" role="presentation">via pass-through PG port</span></span><span id="page342R_mcid32" class="markedContent"> <span dir="ltr" role="presentation">Interference-free integration into existing control </span></span><span id="page342R_mcid33" class="markedContent"><span dir="ltr" role="presentation">systems</span></span></li>
<li><span id="page342R_mcid36" class="markedContent"><span dir="ltr" role="presentation">Centralized configuration of all adapters in the </span></span><span id="page342R_mcid37" class="markedContent"><span dir="ltr" role="presentation">network via PC</span></span></li>
<li><span id="page342R_mcid40" class="markedContent"><span dir="ltr" role="presentation">Power supply directly from controller or via </span></span><span id="page342R_mcid41" class="markedContent"><span dir="ltr" role="presentation">external power supply</span></span></li>
</ul>
<p style="text-align: justify"><span id="page342R_mcid5" class="markedContent"> <span dir="ltr" role="presentation">Integration</span> <span dir="ltr" role="presentation">of</span> <span dir="ltr" role="presentation">S7-200,</span> <span dir="ltr" role="presentation">S7-300</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">S7-400</span> <span dir="ltr" role="presentation">into</span> <span dir="ltr" role="presentation">Ethernet</span> <span dir="ltr" role="presentation">Architecture</span></span></p>
<p><span id="page342R_mcid8" class="markedContent"> <span dir="ltr" role="presentation">PLC</span> <span dir="ltr" role="presentation">Programming</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">Communication</span> <span dir="ltr" role="presentation">via</span> <span dir="ltr" role="presentation">Interface</span></span></p>
<p><span id="page342R_mcid11" class="markedContent"> <span dir="ltr" role="presentation">Integration</span> <span dir="ltr" role="presentation">into</span> <span dir="ltr" role="presentation">Product</span> <span dir="ltr" role="presentation">Management</span> <span dir="ltr" role="presentation">and</span> <span dir="ltr" role="presentation">Visualization</span> <span dir="ltr" role="presentation">Applications</span></span></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview927f-010d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview927f-010d"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb927f-010d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb927f-010d"><span class="vc_tta-title-text">Technical Data</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb927f-010d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb927f-010d"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb927f-010d" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb927f-010d"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview927f-010d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview927f-010d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3><strong>With the Echolink S7 Compact, you can integrate  S7-200, S7-300 and S7-400 via 10/100 Mbit Ethernet networks</strong></h3>
<ul class="default-list">
<li>Direct communication with one or more controllers over any TCP fabric<br />
Supports up to 16 simultaneous connections</li>
<li>Use standard TCP/IP for communication within the plant or company network and with the Internet</li>
<li>Extended communication using MPI or PROFIBUS ports via PG port.</li>
<li>interference-free integration into an existing control system</li>
<li>Central configuration of all adapters on the network via NetCon S7 software</li>
<li>Power supply directly from controller or via external power supply</li>
<li>Cost-effective solution alternative</li>
</ul>
<h3>Programming Adapter Supporting all Relevant S7 Engineering Tools</h3>
<ul class="default-list">
<li>Interface for programming controllers via Ethernet</li>
<li>Compatibility with STEP7, TIA-Portal, WinCC and WinCC flexible</li>
<li>Display and configuration of the adapter in STEP7 or TIA portal</li>
</ul>
<h3>Application Integration through RFC1006 and OPC UA</h3>
<ul class="default-list">
<li>Connection to HMI station and PLC directly via RFC1006 Ethernet protocol</li>
<li>Support of OPC and OPC UA by using dataFEED OPC Suite for integration into higher-level systems, e.g. for production management</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb927f-010d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb927f-010d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Data</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>Hardware Requirements</td>
<td>Ethernet Interface</td>
</tr>
<tr>
<td>PC Connection</td>
<td>RJ45</td>
</tr>
<tr>
<td>Supported Controllers</td>
<td>Siemens S7-200, Siemens S7-300, Siemens S7-400</td>
</tr>
<tr>
<td>Supported Bus Systems</td>
<td>PROFIBUS, MPI</td>
</tr>
<tr>
<td>Communication Type</td>
<td>Ethernet 100 BASE-TX/10 BASE-T</td>
</tr>
<tr>
<td>Supported Transfer Rates to PLC</td>
<td>9.6 KBit/s … 12 MBit/s with automatic detection</td>
</tr>
<tr>
<td>Supported Transfer Rates to PC</td>
<td>10 / 100 MBit/s</td>
</tr>
<tr>
<td>Simultaneous Connections</td>
<td>16 TCP/IP, 32 MPI / PROFIBUS Connections</td>
</tr>
<tr>
<td>Power Supply</td>
<td>24V ± 25%, external or from Controller</td>
</tr>
<tr>
<td>Galvanic Isolation</td>
<td>Yes</td>
</tr>
<tr>
<td>Temperature Range</td>
<td>0°C … +55°C</td>
</tr>
<tr>
<td>Housing, Dimensions (W x H x D)</td>
<td>40,6 mm x 16,7 mm x 74,3 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>Approximately 40g</td>
</tr>
<tr>
<td>Approvals</td>
<td>CE</td>
</tr>
<tr>
<td rowspan="1">Protection Class</td>
<td rowspan="1">IP20</td>
</tr>
<tr>
<td rowspan="1">Configuration Software</td>
<td rowspan="1">NetCon S7 for Local and Remote Configuration</td>
</tr>
<tr>
<td rowspan="1">Supported Application Software</td>
<td rowspan="1">Siemens TIA Portal V11-V13, Siemens STEP 7 V5.5, Siemens WinCC, Siemens WinCC flexible, Siemens ProTool</td>
</tr>
<tr>
<td rowspan="1">System Requirements</td>
<td rowspan="1">PC/PG with Windows XP, Windows 7, Windows 8, Windows 10, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb927f-010d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb927f-010d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: Echolink S7 Compact</h4>
<p>Technical specifications.</p>
</div>
<p><a class="dl-link" href="http://ca.atevatech.com/wp-content/uploads/sites/3/2018/04/echolinkS7compact_D_EN_170901_402.pdf" target="_blank" rel="noopener">Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>User Manual</h4>
<p>Getting started guide.</p>
</div>
<p><a class="dl-link" href="http://ca.atevatech.com/wp-content/uploads/sites/3/2018/04/Getting_Started_echolink_S7-compact_V100_EN.pdf" target="_blank" rel="noopener">Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb927f-010d" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb927f-010d" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="table-responsive">
<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>ATV-GPL-CS-191000</td>
<td>echolink S7-compact</td>
</tr>
</tbody>
</table>
</div>
<h3>Scope of Delivery</h3>
<div class="table-responsive">
<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>Hardware</td>
<td>echolink S7-compact</td>
</tr>
<tr>
<td colspan="1" rowspan="1">Software</td>
<td rowspan="1">Configuration Software NetCon S7 on CD-ROM (also downloadable from Softing website)</td>
</tr>
<tr>
<td colspan="1" rowspan="1">Documentation</td>
<td rowspan="1">Product handbook and configuration tutorials on CD-ROM (also downloadable from Softing website)</td>
</tr>
</tbody>
</table>
</div>
<h3>Additional Products and Services</h3>
<div class="table-responsive">
<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>ATV-LRL-DY-134501</td>
<td>dataFEED OPC Suite</td>
</tr>
<tr>
<td rowspan="1">ATV-LRL-DY-132101</td>
<td rowspan="1">dataFEED OPC Server Siemens</td>
</tr>
<tr>
<td rowspan="1">ATV-GAA-DX-145111</td>
<td rowspan="1">uaGate SI</td>
</tr>
<tr>
<td rowspan="1">ATV-GAL-YY-143101</td>
<td rowspan="1">echocollect e (and other echocollect variants)</td>
</tr>
<tr>
<td rowspan="1">110-1000-01</td>
<td rowspan="1">Training “Industrial Ethernet – Troubleshooting in Automation“, 3 days</td>
</tr>
</tbody>
</table>
</div>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/echolink-s7-compact/">Echolink S7 Compact: the adaptator for S7 Communication</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		