<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ethernet IP | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/product-category/ep/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Tue, 10 Mar 2026 22:35:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>Ethernet IP | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SPI 3 &#8211; Serial Device to Profibus</title>
		<link>https://www.atevatech.net/produit/spi3-serial-device-to-profibus/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=spi3-serial-device-to-profibus</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Mon, 28 Oct 2024 09:44:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=37919</guid>

					<description><![CDATA[<h1 class="">SPI 3 - Serial PROFIBUS Interface</h1>
The post <a href="https://www.atevatech.net/produit/spi3-serial-device-to-profibus/">SPI 3 – Serial Device to Profibus</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1 class="">SPI 3 &#8211; Serial PROFIBUS Interface</h1>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="1180" height="574" src="https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d.webp" class="vc_single_image-img attachment-full" alt="SPI3-RS232" title="csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d" srcset="https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d.webp 1180w, https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d-400x195.webp 400w, https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d-300x146.webp 300w, https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d-1024x498.webp 1024w, https://www.atevatech.net/wp-content/uploads/2024/10/csm_SPI_3_application_EN_rgb_1200px_ca01e87a4d-768x374.webp 768w" sizes="(max-width: 1180px) 100vw, 1180px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1 class="">SPI 3 &#8211; Serial PROFIBUS Interface</h1>
<h2 class="">Connecting Serial Devices to PROFIBUS Networks</h2>
<p style="text-align: justify">By using the <strong>SPI 3</strong>, devices with serial interface are integrated in PROFIBUS as DP slaves. Depending on the application, various protocols and physical interfaces are available. In decentralized PROFIBUS installations, the SPI 3 replaces the serial interface inside the PLC. The SPI 3 is configured via the respective PROFIBUS DP master by means of the SPI 3 GSE file. The PROFIBUS IO range can be flexibly configured. The SPI 3 is suitable for simple applications, such as connecting text displays or barcode scanners, as well as for more complex applications such as the integration of identification systems, scales, controllers and laboratory equipment.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42"><span class="vc_tta-title-text">Misc</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1693568533767-1aba12d6-cdbc98c3-7cccec8c-4a42" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1693568533767-1aba12d6-cdbc98c3-7cccec8c-4a42"><span class="vc_tta-title-text">Video</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>Integration of devices with serial interface as DP slave devices in PROFIBUS networks</li>
<li>Available for various protocols and physical Interfaces</li>
</ul>
<h4>Functions</h4>
<ul>
<li>DP slave with transmission rate of 9.6 kbit/s up to 12 Mbit/s</li>
<li>Serial transmission rate of 110 bit/s up to 57.6 kbit/s (depending on the protocol)</li>
<li>Serial interface available as RS 232, RS 422 or RS 485</li>
<li>Configuration with GSD file via the PROFIBUS DP master</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: SPI 3</h4>
<p>Serial Device to Profibus converter specifications.</p>
</div>
<p><a class="dl-link" href="https://atevatech.aztgrp.net/index.php/s/5rXdfA6SHziZwMB" target="_blank" rel="noopener">Download</a></div>
</div>
<div class="dl-form-box">
<h3>SPI 3 &mdash; Cloud Access</h3>
<p>Access to software, documentation and GSD files via our secure cloud.</p>
<div class="dl-item">
<div class="dl-item-info">
<h4>Drivers &amp; Software</h4>
<p>Doku Media Kits (ASCII, MODBUS, Sartocheck), GSD files.</p>
</div>
<p><a class="dl-link popup-download" data-category="Drivers &amp; Software" href="https://atevatech.aztgrp.net/index.php/s/5rXdfA6SHziZwMB">Request Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Documentation</h4>
<p>Installation guide, release notes.</p>
</div>
<p><a class="dl-link popup-download" data-category="Documentation" href="https://atevatech.aztgrp.net/index.php/s/5rXdfA6SHziZwMB">Request Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Other</h4>
<p>Additional resources.</p>
</div>
<p><a class="dl-link popup-download" data-category="Other" href="https://atevatech.aztgrp.net/index.php/s/5rXdfA6SHziZwMB">Request Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<header>
<h3 class="">Order Information</h3>
</header>
<table class="contenttable twocol">
<tbody>
<tr>
<td>Scope of Delivery</td>
<td></td>
</tr>
<tr>
<td>Hardware</td>
<td>SPI 3</td>
</tr>
<tr>
<td>Documentation</td>
<td>On Website</td>
</tr>
</tbody>
</table>
<table class="contenttable twocol">
<tbody>
<tr>
<td>Order Numbers</td>
<td></td>
</tr>
<tr>
<td>GPA-NS-011236</td>
<td>SPI 3 RS 232</td>
</tr>
<tr>
<td>GPA-NS-011237</td>
<td>SPI 3 RS 422</td>
</tr>
<tr>
<td>GPA-NS-011238</td>
<td>SPI 3 RS 485</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7cccec8c-4a42" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Misc</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1693568533767-1aba12d6-cdbc98c3-7cccec8c-4a42" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1693568533767-1aba12d6-cdbc98c3-7cccec8c-4a42" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Video</span></a></h4></div><div class="vc_tta-panel-body"></div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/spi3-serial-device-to-profibus/">SPI 3 – Serial Device to Profibus</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Smartlink HW-DP</title>
		<link>https://www.atevatech.net/produit/smartlink-hw-dp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=smartlink-hw-dp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Fri, 31 May 2024 19:24:08 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=37025</guid>

					<description><![CDATA[<p>Asset Management and Parameterization of HART devices</p>
<p>Asset Management and Parameterization of PROFIBUS Devices</p>
<p>Direct Access to Process data from your PROFIBUS Network</p>
The post <a href="https://www.atevatech.net/produit/smartlink-hw-dp/">Smartlink HW-DP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1 class="">SmartLink DP for asset Management Access Point on PROFIBUS DP networks</h1>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="580" height="541" src="https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP2.png" class="vc_single_image-img attachment-full" alt="smartlink DP" title="SmartLink DP2" srcset="https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP2.png 580w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP2-400x373.png 400w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP2-300x280.png 300w" sizes="(max-width: 580px) 100vw, 580px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<header>
<h2 class="">Connection of PROFIBUS and HART devices to HART IP, OPC UA, MQTT and FDT</h2>
</header>
<p style="text-align: justify"><strong>smartLink HW-DP</strong> provides PLC independent access to PROFIBUS DP Networks. It enables Plant Asset Management for field devices using standard industry tools and allows using HART IP as a standardized format. smartLink HW-DP is a compact tool that can be integrated without interfering with the operation of existing installations. Thus, it enables Industry 4.0 connectivity for new and existing PROFIBUS DP networks.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1180" height="575" src="https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP.png" class="vc_single_image-img attachment-full" alt="smartLink DP" title="SmartLink DP" srcset="https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP.png 1180w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP-400x195.png 400w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP-300x146.png 300w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP-1024x499.png 1024w, https://www.atevatech.net/wp-content/uploads/2024/05/SmartLink-DP-768x374.png 768w" sizes="(max-width: 1180px) 100vw, 1180px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">Technical Data</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">Training</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064"><span class="vc_tta-title-text">Misc</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1693568533767-1aba12d6-cdbc98c3-7ccc31e1-5064" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1693568533767-1aba12d6-cdbc98c3-7ccc31e1-5064"><span class="vc_tta-title-text">Video</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools</h4>
<ul>
<li>Independent of configuration tools</li>
<li>Centralized and time-saving parameterization of PROFIBUS and HART field devices directly from the control room</li>
<li>Access from Plant Asset Management applications for field devices configuration based on FDT / DTM and EDDL standards (acyclic master)</li>
</ul>
<h4>Ethernet Access Point to PROFIBUS DP</h4>
<ul>
<li>Provides 2<sup>nd</sup> channel to access the field devices</li>
<li>Acts as PROFIBUS DP master class 2</li>
<li>Support of one PROFIBUS DP segment</li>
</ul>
<h4>Key Component for Transition to State-of-the-Art Technology</h4>
<ul>
<li>Re-use of existing PROFIBUS segments without requiring modification</li>
<li>Access to cyclic and acyclic data via HART-IP and OPC UA</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Data</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<header>
<h3 class="">Asset Management and Parameterization of HART Devices</h3>
</header>
<div class="ce-textpic ce-center ce-above">
<div class="ce-bodytext">
<h4>Configuration, Parameterization, Plant Asset Management</h4>
<ul>
<li>Secure, standardized access to devices</li>
<li>Parallel to and independent of the controller</li>
</ul>
<h4>Inexpensive and low-risk integration</h4>
<ul>
<li>Connection of a large number of HART devices without rewiring the devices</li>
<li>Use of existing infrastructure using „HART over PROFIBUS“</li>
<li>Large number of supported Remote IOs</li>
</ul>
<h4>Compatible with established standard applications</h4>
<ul>
<li>Uses HART-IP as standard application protocol</li>
<li>Proven and tested with Emerson AMS Device Manager, ABB FIM, E+H FieldCare and PACTware</li>
</ul>
<header>
<h3 class="">Asset Management and Parameterization of PROFIBUS Devices</h3>
</header>
<div class="ce-textpic ce-center ce-above">
<div class="ce-bodytext">
<h4>Configuration, Parameterization, Plant Asset Management</h4>
<ul>
<li>Secure, standardized access to devices</li>
<li>Parallel to and independent of the controller</li>
</ul>
<h4>Compatible with established standard applications</h4>
<ul>
<li>Drivers available for FDT</li>
<li>Proven and tested with E+H FieldCare and PACTware</li>
</ul>
<header>
<h3 class="">Direct Access to Process Data from PROFIBUS Networks</h3>
</header>
<div class="ce-textpic ce-center ce-above">
<div class="ce-bodytext">
<h4>Capturing process data directly from the network</h4>
<ul>
<li>Live provision of all process data for further use in typical Industry 4.0 applications such as data analytics</li>
<li>Collecting data directly from the network, replacing the need to access the controller</li>
<li>No intervention in the running process</li>
</ul>
<h4>Secure provision of data using OPC UA</h4>
<ul>
<li>State-of-the-art transmission method in industrial networks</li>
<li>Fast update cycles over OPC UA possible</li>
</ul>
<header>
<h3 class="">Asset Monitoring and Diagnostics in PROFIBUS Networks</h3>
</header>
<div class="ce-textpic ce-center ce-above">
<div class="ce-bodytext">
<h4>Complete inventory of the entire network</h4>
<ul>
<li>I&amp;M data from all connected devices</li>
<li>Automated live queries without configuration</li>
</ul>
<h4>Secure provision of data using MQTT</h4>
<ul>
<li>State-of-the-art transmission method for cloud connectivity</li>
<li>Information model based on OPC UA Companion Specifications for PROFINET</li>
</ul>
<h4>Health monitoring of all connected devices</h4>
<ul>
<li>Diagnostic messages and status of all bus stations</li>
<li>Statistics parameters for the entire network</li>
</ul>
<h4>Integrated with Softing plantPerfect Monitor application</h4>
<ul>
<li>Use the plantPerfect Monitor application to monitor the network with all its devices</li>
</ul>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: SmartLink HW-DP</h4>
<p>Technical specifications and features.</p>
</div>
<p><a class="dl-link" href="https://www.atevatech.net/wp-content/uploads/2024/06/smartLink_HW-DP.pdf" target="_blank" rel="noopener">Download</a></div>
</div>
<div class="dl-form-box">
<h3>SmartLink HW-DP &mdash; Cloud Access</h3>
<p>Access to software, documentation and drivers via our secure cloud.</p>
<div class="dl-item">
<div class="dl-item-info">
<h4>Drivers &amp; Software</h4>
<p>Software, firmware and configuration tools.</p>
</div>
<p><a class="dl-link popup-download" data-category="Drivers &amp; Software" href="https://atevatech.aztgrp.net/index.php/s/WgfC5z96TH98TeF">Request Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Documentation</h4>
<p>User manual, quick start guide and technical documentation.</p>
</div>
<p><a class="dl-link popup-download" data-category="Documentation" href="https://atevatech.aztgrp.net/index.php/s/WgfC5z96TH98TeF">Request Download</a></div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Other</h4>
<p>Additional resources and documentation.</p>
</div>
<p><a class="dl-link popup-download" data-category="Other" href="https://atevatech.aztgrp.net/index.php/s/WgfC5z96TH98TeF">Request Download</a></div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable twocol">
<tbody>
<tr>
<td>Scope of Delivery</td>
<td></td>
</tr>
<tr>
<td>Hardware</td>
<td>smartLink HW-DP</td>
</tr>
<tr>
<td>Documentation</td>
<td>On Website</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="contenttable twocol">
<tbody>
<tr>
<td>Order Numbers</td>
<td></td>
</tr>
<tr>
<td>GEA-YN-026000</td>
<td>smartLink HW-DP</td>
</tr>
<tr>
<td>GEA-YN-026001</td>
<td>smartLink HW-DP 50, Hardware preloaded with licenses for 50 devices</td>
</tr>
<tr>
<td>GEA-YN-026002</td>
<td>smartLink HW-DP 100, Hardware preloaded with licenses for 100 devices</td>
</tr>
<tr>
<td>GEA-YN-026003</td>
<td>smartLink HW-DP 250, Hardware preloaded with licenses for 250 devices</td>
</tr>
<tr>
<td>GEA-YN-026004</td>
<td>smartLink HW-DP 375, Hardware preloaded with licenses for 375 devices</td>
</tr>
<tr>
<td>LRA-NN-027004</td>
<td>smartPlus DP, License access to one field device</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="contenttable twocol">
<tbody>
<tr>
<td colspan="2">Additional Products and Services</td>
</tr>
<tr>
<td>DBA-KM-020410</td>
<td>mobiLink – Mobile HART interface</td>
</tr>
<tr>
<td>LRL-TG-020000</td>
<td>plantPerfect Monitor, perpetual licence including 1 year software updates for 1 device</td>
</tr>
<tr>
<td>LMA-TG-020000</td>
<td>plantPerfect Monitor, 1 year software updates for 1 device</td>
</tr>
<tr>
<td>LAA-TG-020000</td>
<td>plantPerfect Monitor, 1 year rental licence for 1 device</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Training</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a38bf-dfeb25cc-925c8e02-b7f56dac-f4caa4af-bd0098c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Misc</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable low-row table-striped">
<tbody>
<tr>
<td colspan="3">smartLink HW-DP</td>
</tr>
<tr>
<td><strong>Hardware</strong></td>
<td>Processor</td>
<td>Intel Cyclone V SoC with dual-core ARM Cortex-A9</td>
</tr>
<tr>
<td></td>
<td>Status LEDs (Gateway)</td>
<td>PWR, RUN, ERR, BUS</td>
</tr>
<tr>
<td></td>
<td>Real-Time Clock</td>
<td>Real-Time clock with buffering, setting the time via browser or by NTP server (buffer time depends on conditions such as ambient temperature and duration of use)</td>
</tr>
<tr>
<td><strong>Interfaces</strong></td>
<td>Ethernet</td>
<td>1 x IEEE802.3 10BASE-T/100BASE-TX/1000BASE-T, Connector: RJ45</td>
</tr>
<tr>
<td></td>
<td>PROFIBUS DP</td>
<td>1 x Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket</td>
</tr>
<tr>
<td><strong>Supported</strong></td>
<td>Communication Protocols</td>
<td>HART-IP, MQTT, OPC UA, PROFIBUS DP</td>
</tr>
<tr>
<td></td>
<td>PROFIBUS Remote IOs</td>
<td><strong>Siemens:</strong><br />
ET 200SP: 155-6BU01-0CN0<br />
ET 200iSP: 152-1AA00-0AB0<br />
ET 200M: 153-2BA10-0XB0<br />
<strong>ABB:</strong><br />
S800: CI801, CI840, CI840A<br />
S900: CI920N, CI920S<br />
<strong>Pepperl+Fuchs:</strong><br />
LB: LB8105, LB8106, LB8109<br />
FB: FB8206, FB8209<br />
<strong>R.Stahl:</strong> iS1+: CPM 9440/15-01-11<br />
<strong>Turck:</strong><br />
BL20: BL20-E-GW-DP, BL20-GW-DPV1<br />
excom: GDP 1,5<br />
<strong>WAGO:</strong> I/O System 750: 750-333, 750-833</td>
</tr>
<tr>
<td></td>
<td>HART IO Modules</td>
<td><strong>Siemens:</strong><br />
ET 200SP: 134-6TD00-0CA1, 135-6TD00-0CA1<br />
ET 200iSP: 134-7TD00-0AB0, 135-7TD00-0AB0, 134-7TD50-0AB0, 138-7FA00-0AB0<br />
ET 200M: 332-8TF01-0AB0, 331-7TF00-0AB0, 331-7TF01-0AB0, 331-7TB00-0AB0, 332-8TF00-0AB0<br />
<strong>ABB:</strong><br />
S800: AI815, AO815, AI845, AO845A, AI895, AO895<br />
S900: AI930N, AO930N<br />
<strong>Pepperl+Fuchs:</strong><br />
LB: LB3002, LB3102, LB3103, LB3105, LB4002, LB4005, LB4102, LB4105, LB3005A2, LB3006A, LB3106A, LB4106A, LB7104A<br />
FB: FB3202B1, FB3202B2, FB3205B2, FB3205B3, FB3302B2, FB3305B2, FB4202B2, FB4202B3, FB4205B2, FB4205B3, FB4205C2, FB4302B2, FB7204B3, FB7304B3<br />
<strong>R.Stahl:</strong> iS1+: AIM 9461/12-08-11, AOM 9466/12-08-11, AUM 9468/32-08-11<br />
<strong>Turck:</strong><br />
BL20: BL20-2AIH-I, BL20-2AOH-I<br />
excom: AIH40Ex, AOH40Ex<br />
<strong>WAGO:</strong> I/O System 750: 750-484, 75x-842</td>
</tr>
<tr>
<td></td>
<td>HART-IP Applications</td>
<td>Emerson AMS Device Manager V14.1.1, V14.5<br />
Endress + Hauser Netilion (FieldEdge SGC500)<br />
ABB FIM V3.01</td>
</tr>
<tr>
<td></td>
<td>FDT Applications</td>
<td>PACTware, Endress + Hauser FieldCare</td>
</tr>
<tr>
<td><strong>Physical Properties</strong></td>
<td>Dimensions (H x W x D)</td>
<td>120 mm x 28 mm x 110 mm</td>
</tr>
<tr>
<td></td>
<td>Weight</td>
<td>Approx. 430g</td>
</tr>
<tr>
<td></td>
<td>Power Supply</td>
<td>18 VDC &#8230; 32 VDC; SELV/PELV power supply mandatory<br />
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)</td>
</tr>
<tr>
<td></td>
<td>Typical Power Loss</td>
<td>5 W</td>
</tr>
<tr>
<td></td>
<td>Operating Temperature</td>
<td>-40 °C &#8230; +65 °C (see detailed mounting description in user manual)</td>
</tr>
<tr>
<td></td>
<td>Storage Temperature</td>
<td>-40 °C &#8230; +85 °C</td>
</tr>
<tr>
<td></td>
<td>Relative Humidity</td>
<td>10 % &#8230; 95 %, non-condensing</td>
</tr>
<tr>
<td></td>
<td>Cooling</td>
<td>Convection, no fan</td>
</tr>
<tr>
<td></td>
<td>Mounting</td>
<td>DIN rail 35 mm</td>
</tr>
<tr>
<td></td>
<td>Protection Class</td>
<td>IP20</td>
</tr>
<tr>
<td><strong>Conformity / Standards</strong></td>
<td>CE</td>
<td>Electromagnetic compatibility (EMC) and Restriction of Hazardous Substances (RoHS)<br />
EN 61000-6-2 Generic standards &#8211; Immunity standard for industrial environments<br />
EN 61000-6-4 Generic standards &#8211; Emission standard for industrial environments<br />
EN 55032 Electromagnetic compatibility of multimedia equipment &#8211; Emission Requirements Class A<br />
EN 55011 Industrial, scientific and medical equipment &#8211; Radio-frequency disturbance characteristics –<br />
Limits and methods of measurement Class A<br />
EN IEC 63000:2018 RoHS, Assessment to the restriction of hazardous substances</td>
</tr>
<tr>
<td></td>
<td>FCC</td>
<td>FCC 47 CFR Part 15B Section 15.109 (Class A)</td>
</tr>
<tr>
<td></td>
<td>VCCI</td>
<td>VCCI Voluntary Control Council for Interferences by Information Technology Equipment, April 2015</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1693568533767-1aba12d6-cdbc98c3-7ccc31e1-5064" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1693568533767-1aba12d6-cdbc98c3-7ccc31e1-5064" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Video</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="https://atevatech.aztgrp.net/index.php/s/XoSsT3ie8gqWmZm" target="_blank" rel="noopener">SmartLink DP&#8217; videos available in here !</a></p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/produit/smartlink-hw-dp/">Smartlink HW-DP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>epGateDP</title>
		<link>https://www.atevatech.net/produit/epgatedp-2/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=epgatedp-2</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Thu, 13 Apr 2023 13:15:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.atevatech.net/?post_type=product&#038;p=34677</guid>

					<description><![CDATA[<p>Ethernet IP Gateway</p>
<div id="sconnect-is-installed" style="display: none;">2.15.0.0</div>
<div id="sconnect-is-installed" style="display: none;">2.15.0.0</div>
The post <a href="https://www.atevatech.net/produit/epgatedp-2/">epGateDP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Ethernet/IP to PROFIBUS DP Master Gateway</h2>
<h3>Simple connection of PROFIBUS DP Slave Devices to Ethernet/IP Control Systems via Internal I/O Mapping</h3>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>With <strong>epGate DP</strong> it is possible to integrate one PROFIBUS DP segment into Ethernet/IP control systems. With epGate DP the engineering costs can be reduced since it re-uses existing PROFIBUS DP segment without the requiring modification. It enables configuration, parameterization and plant asset management using standard industry tools.</p>
<p>Similar Solutions<br />
epGate PA: Integrate up to 4 PROFIBUS PA segments into ethernet/IP systems<br />
epGate PB: Integrate up to 2 PROFIBUS PA segments &amp; 1 PROFIBUS DP segment into ethernet/IP systems<br />
epGate PN: Integrate PROFINET I/O devices into ethernet/IP systems</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="1180" height="574" src="https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px.png" class="vc_single_image-img attachment-full" alt="" title="epGate_DP_application_EN_72dpi_1180px" srcset="https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px.png 1180w, https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px-400x195.png 400w, https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px-300x146.png 300w, https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px-1024x498.png 1024w, https://www.atevatech.net/wp-content/uploads/2023/04/epGate_DP_application_EN_72dpi_1180px-768x374.png 768w" sizes="auto, (max-width: 1180px) 100vw, 1180px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#Overview1bb0-d189" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Overview1bb0-d189"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb1bb0-d189" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a38bf-dfeb1bb0-d189"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb1bb0-d189" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a38bf-dfeb1bb0-d189"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="Overview1bb0-d189" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Overview1bb0-d189" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools</h4>
<ul>
<li>Supports major EtherNet/IP engineering tools such as Studio 5000 and AMS Device Manager</li>
<li>Included CommDTM allowing use in FDT/DTM frame applications</li>
<li>EDD-based device parametrization using Siemens Simatic PDM</li>
</ul>
<h4>Direct Connectivity to PROFIBUS Segments</h4>
<ul>
<li>Single access point to PROFIBUS DP segment from EtherNet/IP networks</li>
<li>Acting as EtherNet/IP device (adapter) and PROFIBUS DP master</li>
<li>Support of one PROFIBUS DP segment</li>
<li>Support of up to 32 PROFIBUS devices</li>
</ul>
<h4>Key Component for Transition to State-of-the-Art Technology</h4>
<ul>
<li>Re-use of existing PROFIBUS segments without requiring modification</li>
<li>Support of common control systems e.g. Emerson DetlaV or Rockwell Control Logix</li>
<li>Support of DLR for redundant communication in the ring with EtherNet/IP</li>
</ul>
<h4>Simple Integration Through Add-On Instructions</h4>
<ul>
<li>Data access of PLC program to PROFIBUS devices without requiring detailed PROFIBUS knowledge</li>
<li>Mapping between the two protocols generated by provided tools</li>
<li>Use of Add-On Instructions (AOI) containing detailed PROFIBUS data type definitions</li>
<li>Transparent communication overcoming protocol differences</li>
<li>Optimized for usage with Allen Bradley controllers</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a38bf-dfeb1bb0-d189" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a38bf-dfeb1bb0-d189" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="dl-section">
<h3>Documents</h3>
<div class="dl-item">
<div class="dl-item-info">
<h4>Datasheet: epGate DP</h4>
<p>Technical specifications and features.</p>
</div>
<p><a class="dl-link" href="https://atevatech.aztgrp.net/s/Qk9gSrLKBbZMJE2" target="_blank" rel="noopener">Download</a></p>
</div>
</div>
<div class="dl-form-box">
<h3>epGate DP — Cloud Access</h3>
<p>Access to firmware, drivers and documentation via our secure cloud.</p>
<div class="dl-item">
<div class="dl-item-info">
<h4>Drivers &amp; Software</h4>
<p>Firmware, Universal PROFIBUS Driver, PROFIdtm, PDM Libraries, Discovery Tool.</p>
</div>
<p><a class="dl-link popup-download" href="https://atevatech.aztgrp.net/s/tTNY5DG2fHyGPfq" data-category="Drivers &amp; Software">Request Download</a></p>
</div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Documentation</h4>
<p>epGate PA/PB/DP User Guide and technical documentation.</p>
</div>
<p><a class="dl-link popup-download" href="https://atevatech.aztgrp.net/s/tTNY5DG2fHyGPfq" data-category="Documentation">Request Download</a></p>
</div>
<div class="dl-item">
<div class="dl-item-info">
<h4>Other</h4>
<p>Additional resources.</p>
</div>
<p><a class="dl-link popup-download" href="https://atevatech.aztgrp.net/s/tTNY5DG2fHyGPfq" data-category="Other">Request Download</a></p>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a38bf-dfeb1bb0-d189" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a38bf-dfeb1bb0-d189" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable twocol">
<tbody>
<tr>
<td><strong>Scope of Delivery</strong></td>
<td></td>
</tr>
<tr>
<td>Hardware</td>
<td>epGate DP Gateway</td>
</tr>
<tr>
<td>Documentation</td>
<td>On Website</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="contenttable twocol">
<tbody>
<tr>
<td><strong>Order Numbers</strong></td>
<td></td>
</tr>
<tr>
<td>GCA-CN-024706</td>
<td><strong>epGate DP</strong>, EtherNet/IP to PROFIBUS DP Gateway. Supports <strong>1 PROFIBUS DP segment</strong> (RS485).</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="contenttable twocol">
<tbody>
<tr>
<td><strong>Additional Products and Services</strong></td>
<td></td>
</tr>
<tr>
<td>LRL-DY-134501</td>
<td><strong>dataFEED OPC Suite</strong>, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge</td>
</tr>
<tr>
<td>GCA-CN-024708</td>
<td><strong>epGate PB</strong>, EtherNet/IP to PROFIBUS Gateway. Supports <strong>2 PA segments</strong> (up to 32 PA devices, MBP physical layer) and <strong>1 PROFIBUS DP segment</strong> (RS485).</td>
</tr>
<tr>
<td>GCA-CL-024702</td>
<td><strong>epGate PA</strong>, EtherNet/IP to PROFIBUS PA Gateway. Supports <strong>up to 2 PA segments</strong> (up to 32 PA devices).</td>
</tr>
<tr>
<td>GCA-CL-024704</td>
<td><strong>epGate PA</strong>, EtherNet/IP to PROFIBUS PA Gateway. Supports <strong>up to 4 PA segments</strong> (up to 64 PA devices).</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
<div id="sconnect-is-installed" style="display: none;">2.15.0.0</div>
<div id="sconnect-is-installed" style="display: none;">2.15.0.0</div>
</div>The post <a href="https://www.atevatech.net/produit/epgatedp-2/">epGateDP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
