<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Switches &quot;Marine&quot; ( DNV ) | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/fr/category/switch/switch-dnv/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Thu, 30 Aug 2018 05:50:32 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>Switches &quot;Marine&quot; ( DNV ) | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IES-2208CA-DNV</title>
		<link>https://www.atevatech.net/fr/ies-2208ca-dnv/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ies-2208ca-dnv</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 23 Aug 2017 16:38:45 +0000</pubDate>
				<category><![CDATA[Switches "Marine" ( DNV )]]></category>
		<category><![CDATA[Switches administrables]]></category>
		<category><![CDATA[Série 2000]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=1886</guid>

					<description><![CDATA[<p>Switch industriel administrable : IES-2208CA-DNV - 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo</p>
The post <a href="https://www.atevatech.net/fr/ies-2208ca-dnv/">IES-2208CA-DNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Switch LANTECH : IES-2208CA-DNV</h2>
<h3>Switch Industriel IES-2208CA-DNV : 8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo</h3>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		<h2 class="wpb_heading wpb_singleimage_heading">IES-2208CA-DNV</h2>
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/IES-2208CA_300x177-150x150.png" class="vc_single_image-img" loading="lazy"" /></div><figcaption class="vc_figure-caption">IES-2208CA-DNV</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>IES-2208CA-DNV : 8* 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo, administrable</h2>
<p>&nbsp;</p>
<ul>
<li>Certification DNV pour réseaux embarqués marine et plate-forme Off-Shore</li>
<li>Fonction Pro-Ring pour la gestion des topologies réseau en anneau</li>
<li>Temps de cicatrisation inférieur à 20 ms</li>
<li>Alimentation protégée contre les inversions de polarité et sur-charge en courant</li>
</ul>
<p><img decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/c1d2-150x150.png" width="55" height="55" /><img decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/dnv-150x150.png" width="55" height="55" /><img decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/ul-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/fcc-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/ce-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/weee-150x150.png" width="55" height="55" /><img loading="lazy" decoding="async" class="" src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/rohs-150x150.png" width="55" height="55" /></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Détails Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Formation</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71"><span class="vc_tta-title-text">Téléchargement</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="tabs-caracteristique" class="ui-tabs-panel ui-widget-content ui-corner-bottom">
<ul>
<li>switch Ethernet administrable 12 ports:
<ul>
<li>8 ports 10/100TX</li>
<li>2 ports combo RJ48 10/100/1000TX et module fibre Mini-GBIC, dual mode 10/100/1000T</li>
</ul>
</li>
<li>méthode de commutation &#8220;stockage et retransmission&#8221;</li>
<li>taux de commutation: 5.6 Gbps</li>
<li>table d&#8217;adresses MAC 8K</li>
<li>bôiteir métal IP 30, fixation rail DIN et murale</li>
<li>entrées alimentation protégées contre les inversions de polarité et sur-charge en courant</li>
<li>fonction Pro-Ring pour la gestion des toplogies en anneau: Couple-Ring et Dual Homing, auto-cicatrisation en moins de 20 ms pour une toplogie à 50 switches</li>
<li>Port-Based VLAN, IEEE 802.1Q Tag VLAN, GVRP</li>
<li>802.1d Spanning Tree &amp; 802.1w RSTP</li>
<li>IGMP avec  fonctions Snooping et Query  pour les applications multimédia</li>
<li>entrée alimentation protégée contre les pics de tension jusqu&#8217;à 3000 Vdc</li>
<li>port Ethernet protégé contre les décharges électro-statiques, supporte jusqu&#8217;à 6000 Vdc</li>
<li>qualité de service (QoS) 802.1p, 4 files d&#8217;attente par port</li>
<li>journaux d&#8217;événements:
<ul>
<li>système Serveur/Client</li>
<li>alertes sytèmes envoyées par e-mail</li>
<li>sortie relais activée</li>
</ul>
</li>
<li>Port Trunk avec LACP</li>
<li>supporte 802.1ab LLDP</li>
<li>vecteurs SNMP :
<ul>
<li>démarrage à froid</li>
<li>états de fonctionnement de l&#8217;alimentation</li>
<li>défaut d&#8217;authentification</li>
<li>port Link up/Link down</li>
<li>modification de la toplogie en anneau</li>
</ul>
</li>
<li>mise à jour du microcode et sauvegarde/restauration du système par un accès TFTP</li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails Techniques</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Spécifications Matériel</p>
<p>&nbsp;</p>
<table border="1" width="540" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Normes standards</strong></td>
<td>IEEE802.3 10Base-T Ethernet<br />
IEEE802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z fibre Gigabit<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.1x Authentification (Radius)<br />
IEEE802.1ab LLDP</td>
</tr>
<tr>
<td><strong>Architecture</strong></td>
<td>Taux de commutation: 5.6 Gbps</td>
</tr>
<tr>
<td><strong>Taux de transfert</strong></td>
<td>Ethernet: 14 880 pps par port<br />
Fast Ethernet: 148 800 pps par port<br />
Gigabit Ethernet: 1,488,000 pps par port</td>
</tr>
<tr>
<td><strong>Adresse MAC</strong></td>
<td>Table d&#8217;adressage MAC 8K</td>
</tr>
<tr>
<td><strong>Mémoire Flash<br />
</strong></td>
<td>4 Mo</td>
</tr>
<tr>
<td><strong>Mémoire Vive</strong></td>
<td>32 Mo</td>
</tr>
<tr>
<td><strong>Connectique</strong></td>
<td>10/100TX: 8x ports RJ-45 avec fonction auto MDI/MDI-X<br />
10/100/1000T/SFP Combo port: 2x RJ-45 + 2x 100/1000 SFP socket.<br />
RS-232 connecteur: type RJ-45</td>
</tr>
<tr>
<td><strong>Câble réseau</strong></td>
<td>10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td><strong>Fibre optique<br />
</strong></td>
<td>Multi-mode: 50/125um~62.5/125um<br />
Mono-mode: 9/125um<br />
distance: 2km (Multi-mode)/30km (Mono-mode)<br />
Longueur d&#8217;onde: 1310nm (Multi-mode/Mono-mode)</td>
</tr>
<tr>
<td><strong>Protocole</strong></td>
<td>CSMA/CD</td>
</tr>
<tr>
<td><strong>Température de fonctionnement</strong></td>
<td>-40°C ~ 75°C</td>
</tr>
<tr>
<td><strong>Température de stockage</strong></td>
<td>-40°C ~ 85°C</td>
</tr>
<tr>
<td><strong>Protection </strong></td>
<td>surchage en courant<br />
inversion de polarité</td>
</tr>
<tr>
<td><strong>Alimentation</strong></td>
<td>9,5 à 60 Vdc<br />
alimentation avec entrées redondantes<br />
bloc de connexions détachable<em><br />
</em></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td>74 (W) x 105 (D) x 182 (H) mm</td>
</tr>
<tr>
<td><strong>Indice de protection</strong></td>
<td> IP 30</td>
</tr>
<tr>
<td><strong>CEM</strong></td>
<td>FCC Class A,<br />
CE EN61000-4-2 (ESD),<br />
CE EN61000-4-3 (RS),<br />
CE EN61000-4-4 (EFT),<br />
CE EN61000-4-5 (Surge),<br />
CE EN61000-4-6 (CS),<br />
CE EN61000-4-8,<br />
CE EN61000-4-11,<br />
CE EN61000-6-2,<br />
CE EN61000-6-4</td>
</tr>
<tr>
<td><strong>Sécurité</strong></td>
<td>CE/EN60950-1</td>
</tr>
<tr>
<td><strong>Chocs et Vibrations</strong></td>
<td>IEC60068-2-32 (chute libre)<br />
IEC60068-2-27 (choc)<br />
IEC60068-2-6 (vibration)</td>
</tr>
<tr>
<td><strong>MTBF</strong></td>
<td>220 111 h</td>
</tr>
<tr>
<td><strong>Fixation</strong></td>
<td>En option : rail DIN ou murale</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Spécifications Logiciel</h2>
<p>&nbsp;</p>
<table border="1" width="560" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Administration</strong></td>
<td>SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td><strong>SNMP MIB<br />
</strong></td>
<td>RFC 1215 Traps MIB, RFC 1213 MIBII,<br />
RFC 1157 SNMP MIB, RFC 1493 Bridge MIB,<br />
RFC 2674 VLAN MIB, RFC 1643 EtherLike,<br />
RFC 1757 Rmon, RSTP MIB,<br />
Private MIB, PoE MIB, UPS MIB, LLDP MIB</td>
</tr>
<tr>
<td><strong>VLAN</strong></td>
<td>VLAN par port<br />
VLAN à balisage 802.1Q (256 entrées)/ VLAN ID ( VLAN ID de 1 à 4094)<br />
GVRP (256 Groupes)<br />
Double VLAN à balisage (Q in Q)*</td>
</tr>
<tr>
<td><strong>Port Trunk avec LACP</strong></td>
<td>LACP Port Trunk: 4 Trunk groupes/Maximum 4 membres trunk</td>
</tr>
<tr>
<td><strong>LLDP</strong></td>
<td>permet au switch de communiquer son identification et caractéistiques</td>
</tr>
<tr>
<td><strong>Gestion de boucle</strong></td>
<td>Spanning tree 802.1d et Rapid Spanning Tree 802.1w</td>
</tr>
<tr>
<td><strong>Pro-Ring<br />
</strong></td>
<td>Pro-Ring, topologies anneau simple, multi-anneaux et Dual Homing.<br />
fourni un chemin de repli et une auto-cicatrisation en moins de  10 ms</td>
</tr>
<tr>
<td><strong>Qualité de service<br />
</strong></td>
<td> QoS, service par port, balisage et IPV4, IPv4/IPv6</td>
</tr>
<tr>
<td><strong>Classe de Service<br />
</strong></td>
<td>802.1p, file d&#8217;attente à 4 niveaux de priorité par port</td>
</tr>
<tr>
<td><strong>Miroirs de port<br />
</strong></td>
<td> 3 types: RX, TX et RX/TX</td>
</tr>
<tr>
<td><strong>IGMP</strong></td>
<td>IGMP snooping v1,v2<br />
diffusion de groupe (256) et requête IGMP</td>
</tr>
<tr>
<td><strong>Sécurité IP</strong></td>
<td>table de 10 adresses IP autorisées à administrer le switch</td>
</tr>
<tr>
<td><strong>Authentification</strong></td>
<td>IEEE802.1x, RADIUS, SSH, SSL</td>
</tr>
<tr>
<td><strong>Journal système<br />
</strong></td>
<td>enregistrement de l&#8217;activité du système<em><br />
</em></td>
</tr>
<tr>
<td><strong>Envoi d&#8217;alertes</strong></td>
<td>serveur SMTP, 6 comptes e-mails</td>
</tr>
<tr>
<td><strong>Serveur de temps<br />
</strong></td>
<td> synchronisation avec un serveur de temps sur Internet</td>
</tr>
<tr>
<td><strong>Sortie relais<br />
</strong></td>
<td>sur défauts de connexion et alimentation</td>
</tr>
<tr>
<td><strong>Alerte SNMP</strong></td>
<td>1. démarrage à froid<br />
2. perte de lien<br />
3. re-connexion<br />
4. défaut d&#8217;authentification<br />
5. défaut de configuration du port<br />
6. modification de la topologie de l&#8217;anneau</td>
</tr>
<tr>
<td><strong>DHCP</strong></td>
<td>client, serveur</td>
</tr>
<tr>
<td><strong>DNS</strong></td>
<td>fonction DNS client, supporte un serveur DNS primaire et secondaire</td>
</tr>
<tr>
<td><strong>Mise à jour firmware</strong></td>
<td>mise à jour via accès TFTP, sauvegarde et restauration par accès TFTP</td>
</tr>
<tr>
<td><strong>Configuration</strong></td>
<td>fichier de configuration au format binaire pour une installation système rapide</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tab-v1"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>ORDER INFORMATION</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="15%">P/N</th>
<th width="15%">Model name</th>
<th width="70%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-452-DNV</span></td>
<td>IES-2208CA-DNV*</td>
<td>8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-sea rounded">DNV Type Approval*</span></td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1048-24FS</td>
<td>24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1024-24F</td>
<td>24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1240-48S</td>
<td>48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1120-48F</td>
<td>48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES – Mini GBIC (SFP)</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="40%">Description</th>
<th width="10%">Model name</th>
<th width="40%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>8330-162</td>
<td>MINI GBIC 1000SX (LC/0.5km) Transceiver</td>
<td>8330-188</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-163</td>
<td>MINI GBIC 1000SX2 (LC/2km) Transceiver</td>
<td>8330-189</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-165</td>
<td>MINI GBIC 1000LX (LC/10km) Transceiver</td>
<td>8330-186</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8340-0591</td>
<td>MINI GBIC 1000LHX (LC/40km) Transceiver</td>
<td>8330-187</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-166</td>
<td>MINI GBIC 1000XD (LC/50km) Transceiver</td>
<td>8330-180</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-169</td>
<td>MINI GBIC 1000XD (LC/60km) Transceiver</td>
<td>8330-182</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-167</td>
<td>MINI GBIC 1000ZX (LC/80km) Transceiver</td>
<td>8330-181</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-170</td>
<td>MINI GBIC 1000EZX (120km) Transceiver</td>
<td>8330-183</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-060</td>
<td>100Base FX 2KM, Multi-mode, LC Transceiver</td>
<td>8330-184</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1490)</td>
</tr>
<tr>
<td>8330-065</td>
<td>100Base FX 5KM, Multi-mode, LC Transceiver</td>
<td>8330-185</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-061</td>
<td>100Base LX 30KM, Single-mode, LC Transceiver</td>
<td>8330-168</td>
<td>MINI GBIC 1000T (100m) Transceiver</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Formation disponible sur demande</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6d8b34-3a71" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/D-IES-2208CA-DNV.pdf" target="_blank">Brochure</a></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/ies-2208ca-dnv/">IES-2208CA-DNV</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		