<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Série 3000 | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/fr/category/switch/serie-3000/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Thu, 30 Aug 2018 05:46:39 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>Série 3000 | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IPGES-3408GSFP</title>
		<link>https://www.atevatech.net/fr/ipges-3408gsfp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipges-3408gsfp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 07 Jan 2018 16:31:54 +0000</pubDate>
				<category><![CDATA[Switch POE]]></category>
		<category><![CDATA[Switches administrables]]></category>
		<category><![CDATA[Série 3000]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=1920</guid>

					<description><![CDATA[<p>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032 &#038; PTP</p>
The post <a href="https://www.atevatech.net/fr/ipges-3408gsfp/">IPGES-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="container">
<div class="post-entry post-entry-type-page post-entry-718">
<div class="entry-content-wrapper clearfix">
<div class="flex_column av_one_half flex_column_div av-zero-column-padding first avia-builder-el-0 el_before_av_one_half avia-builder-el-first ">
<section class="av_textblock_section ">
<div class="avia_textblock ">
<h2><strong>IPGS-3408GSFP</strong></h2>
<h3>8 10/100/1000T PoE at + 4 1000M SFP L2+ Industrial Managed Switch w/ ITU G.8032 &amp; PTP</h3>
</div>
</section>
</div>
</div>
</div>
</div>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		<h2 class="wpb_heading wpb_singleimage_heading">ipgs-3408GSFP</h2>
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://www.atevatech.net/wp-content/uploads/2017/08/IPGS-3408GSFP-E_250x300.png" width="250" height="147" alt="IPGS-3408GSFP-E_250x300" title="IPGS-3408GSFP-E_250x300" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul class="list-unstyled">
<li>Support IEEE802.3at/af up to 30W per port</li>
<li>PoE management incl. Detection and Scheduling</li>
<li>Enhanced G.8032 ring protection &lt; 20ms with easy configuration; Dynamic coupling ring; Aggregation ring*</li>
<li>Miss-wiring avoidance &amp; Repowered auto ring restore (node failure protection)</li>
<li>User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI</li>
<li>Support LACP link aggregation, IGMP v3/router port, DHCP server &amp; DHCP Option82 for Port&amp;VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, TACAS+*, ACL, IPv6, SMS</li>
<li>Environmental Monitoring for temp., voltage &amp; current**</li>
</ul>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#apercu" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-apercu"><span class="vc_tta-title-text">Aperçu</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#details-tech" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-details-tech"><span class="vc_tta-title-text">Détails techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#reference" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-reference"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#trainings" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-trainings"><span class="vc_tta-title-text">Formations</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#downloads" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-downloads"><span class="vc_tta-title-text">Téléchargement</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#accessory" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-accessory"><span class="vc_tta-title-text">Accessoires</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="apercu" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#apercu" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Aperçu</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Lantech IPGS-3408GSFP is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 4 1000M SFP w/8 PoE 802.3af/at Injectors which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.</p>
<p>Compliant with 802.3af/at standard, the Lantech IPGS-3408GSFP is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPGS-3408GSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.</p>
<p>The IPGS-3408GSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-3408GSFP is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.</p>
<p>DHCP option 82 and relay agent function (Port/Vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.</p>
<p>The user friendly UI, innovative auto topology drawing and topology demo makes IPGS-3408GSFP much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IPGS-3408GSFP supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.</p>
<p>Lantech IPGS-3408GSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8/16* MSTI.</p>
<p>The configuration file of Lantech IPGS-3408GSFP can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p>QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p>The IPGS-3408GSFP DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPGS-3408GSFP will immediately send an email &amp; SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.</p>
<p>The optional environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.</p>
<p>The Lantech IPGS-3408GSFP is designed with dual power supply at 48VDC. The 12V model is built with Booster technology that can accept input voltage from 12V ~ 48V and deliver PoE power at 48V to feed the PD. Featured with relay contact alarm function, the IPGS-3408GSFP is able to connect with alarm system in case of power failure. The IPGS-3408GSFP also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.</p>
<p>Lantech IPGS-3408GSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.</p>
<p>The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="details-tech" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#details-tech" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>8 10/100/1000T + 4 1000M SFP (Total 12 Ports Switch)</li>
<li>IEEE 1588 PTP v2 two-step (under 1μs)</li>
<li>Back-plane (Switching Fabric): 24Gbps</li>
<li>16K MAC address table</li>
<li>DDM to support SFP diagnostic function***
<ul>
<li>Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance</li>
</ul>
</li>
<li>9KB Jumbo frame supported on all ports</li>
<li>User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting</li>
<li>Enhanced G.8032 Ring protection in 20ms &lt; 256 switches
<ul>
<li>Support various ring/chain topologies, including dynamic coupling ring&amp; aggregation ring*</li>
<li>Enhanced G.8032 ring configuration with ease</li>
<li>Auto ring configuration(auto mode) for single ring</li>
<li>Co-exist with RSTP on different ports</li>
</ul>
</li>
<li>Aggregation ring for ring redundancy and bandwidth combination*</li>
<li>Dual DC input from 18V~57VDC, HV model with single 90~305VAC or 120~430VDC power input</li>
<li>Provides EFT protection ±4000 VDC for power line.</li>
<li>Supports ±6000 VDC Ethernet ESD protection</li>
<li>LACP load balancing to distribute the load*</li>
<li>Built-in RTC (Real Time Clock) to keep track of time</li>
<li>Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority</li>
<li>IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy</li>
<li>4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*</li>
<li>Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**</li>
<li>DHCP server / client / Port&amp;Vlan based DHCP distribution / DHCP Option 82 supported</li>
<li>Mac based DHCP server to assign IP address that includes dumb switches in DHCP network</li>
<li>Bandwidth Control
<ul>
<li>Ingress packet filter and egress rate limit</li>
<li>Broadcast/multicast packet filter control</li>
</ul>
</li>
<li>Relay alarm output system events</li>
<li>Miss-wiring avoidance
<ul>
<li>LED indicator</li>
<li>Email, traps, or SMS notification</li>
</ul>
</li>
<li>Repowered auto ring restore
<ul>
<li>Ensure the switches in a ring to survive after power breakout is back</li>
<li>The status can be shown in NMS when each switch is back</li>
</ul>
</li>
<li>TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade</li>
<li>System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters</li>
<li>Security
<ul>
<li>SSL/SSH/ACL L2&amp;L3</li>
<li>Port Security: MAC address entries/Filter/MAC-Port binding</li>
<li>IP Security: IP address security management to prevent unauthorized intruder.</li>
<li>Management access control with priority</li>
<li>Login Security: IEEE802.1X/RADIUS</li>
<li>HTTPS for secure access to the web interface</li>
</ul>
</li>
<li>Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application</li>
<li>Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow</li>
<li>Multicast VLAN registration* for metro video</li>
<li>IGMPv1,v2,v3 with Query mode for multi media; GMRP**</li>
<li>Factory reset button to restore setting to factory default</li>
<li>Watchdog design to auto reboot switch CPU is found dead</li>
<li>Optional environmental monitoring for system input voltage, current, ambient temperature</li>
<li>Supports DIDO (Digital Input/Digital Output)</li>
<li>IP30 metal housing with DIN rail and Wall-mount** design</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="reference" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#reference" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-806</span></td>
<td>IGS-3408DSFP</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-807</span></td>
<td>IGS-3408DSFP-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-808</span></td>
<td>IGS-3408DSFP-M</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-809</span></td>
<td>IGS-3408DSFP-M-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-853</span></td>
<td>IGS-3408DSFP-HV</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-854</span></td>
<td>IGS-3408DSFP-HV-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-8531</span></td>
<td>IGS-3408DSFP-HV-M</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-8541</span></td>
<td>IGS-3408DSFP-HV-M-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>OPTIONAL ACCESSORIES &#8211; DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1048-24FS</td>
<td>24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1024-24F</td>
<td>24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1240-48S</td>
<td>48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1120-48F</td>
<td>48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="trainings" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#trainings" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formations</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Formation disponible sur demande</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="downloads" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#downloads" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="http://lantechcom.eu/cms/wp-content/uploads/2015/09/D-IGS-3408GSFP.pdf" target="_blank" rel="noopener">Brochure</a></p>
<p><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/05/M-3-5-Series-WebUI-Users-Manual.pdf" target="_blank" rel="noopener">Manuel utilisateur ( Software )</a></p>
<p><a href="https://www.atevatech.net/wp-content/uploads/2018/01/M-IPGS_IGS-3XXX_5XXX_IP30.pdf" target="_blank" rel="noopener">Manuel utilisateur ( Hardware )</a></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div><div class="vc_tta-panel" id="accessory" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#accessory" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Accessoires</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/ipges-3408gsfp/">IPGES-3408GSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IPGS-3008</title>
		<link>https://www.atevatech.net/fr/ipgs-3008/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipgs-3008</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 20 Aug 2017 19:09:26 +0000</pubDate>
				<category><![CDATA[Switch POE]]></category>
		<category><![CDATA[Switches administrables]]></category>
		<category><![CDATA[Série 3000]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=1828</guid>

					<description><![CDATA[<p>Switch IPGS-3008 : 8*PoE AT/AF 10/100/1000T, L2+</p>
The post <a href="https://www.atevatech.net/fr/ipgs-3008/">IPGS-3008</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Switch Lantech : IPGS-3008</h2>
<h2>8x 10/100/1000TX PoE at/af administrable L2+, anneau G.8032, modèle 12V en option</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		<h2 class="wpb_heading wpb_singleimage_heading">IPGS-3008</h2>
		<figure class="wpb_wrapper vc_figure">
			<a href="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/IPGS-3008.png" target="_blank" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/IPGS-3008.png" class="vc_single_image-img" loading="lazy"" /></a><figcaption class="vc_figure-caption">IPGS-3008</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul class="list-unstyled">
<li>PoE IEEE802.at/af, 30W par port</li>
<li>Gestion des ports PoE, détection et planification</li>
<li>Fonctions de redondance en anneau suivant norme ITU G.8032, cicatrisation de l&#8217;anneau &lt;20 ms</li>
<li>Fonctions d&#8217;administration avancées : LCAP, IGMP v3, QinQ</li>
<li>Accès sécurisé : chiffrement SSH/SSL, 802.1X/Radius, https</li>
<li>Double entrées alimentation, version 12V (9.5V à 57 Vdc) ou (44V à 57 Vdc) pour la version 48V</li>
</ul>
<p><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/rohs2.png" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/CE.png" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/FCC.png" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/TrashCan.png" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/poe-at.jpg" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/itu-ring.jpg" width="50" /><img decoding="async" src="http://www.lantechcom.fr/userfiles/medias/icones/poe-booster.jpg" width="50" /></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecb6dbc-e4f75496-5562"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b436dbc-e4f75496-5562"><span class="vc_tta-title-text">Fonction</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1489133547310-939ec51d-aa6e5496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1489133547310-939ec51d-aa6e5496-5562"><span class="vc_tta-title-text">Détails Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320782574-3b588c5e-ffd46dbc-e4f75496-5562"><span class="vc_tta-title-text">Références</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320754302-7b727c18-3cf06dbc-e4f75496-5562"><span class="vc_tta-title-text">Téléchargement</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320811737-cd23c365-07206dbc-e4f75496-5562"><span class="vc_tta-title-text">Dimensions</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecb6dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><span style="color: #000000;">Le switch LANTECH IPGS-3008 est un switch puissant, à très haute performance L2+, port Gigabit avec 8 10/100/1000T w/8 PoE 802.3af/at, fournissant une rapidité et une sécurité accrue pour le déploiement d&#8217;agrégation de lien. Dans le cas d’utilisation en anneau ITU G,8032, il permet de permuter de direction en moins de 20ms, pour un simple anneau. Administration rapide et facile du QoS, VLAN, GVRP, Sécurité avancée pour SSH/SSL, TACACS+, Ingress/Egress ACL L2/L3, IGMPv1/v2/v3/Router port, DHCP server/relay, « Jumbo frames » ( largement utilisé pour les réseaux moyen et large..) Il support également le protocole « Cisco Discovery » (CDP) et LLDP, afin d’afficher une topology L2 map.</span></p>
<p>&nbsp;</p>
<p><b>PoE AT/AF avec débit jusqu’à 8 Gigabit, détection et programmation du PoE</b></p>
<p>Le switch LANTECH IPGS-3008 supporte une programmation avancée de la fonction PoE pour la détection et la programmation. La détection PoE peut savoir si l’appareil PD ( Powered Device) est bloqué et permet ainsi un redémarrage. La programmation PoE permet d’alimenter en energie, l’appareil selon un timing déterminé. Chaque port PoE, permet d’être dans l’état « ON /OFF », permet de déterminer la puissance délivré à l’appareil PD. ( Watt, Température, courant, Voltage) Affichage par WebGUI</p>
<p><b>Protection de boucle : Re-alimentation en energie si la boucle est rompue, Alerte par email, trap ou SMS</b></p>
<p>Le switch IPGS-3008 possède d’autres fonctionalitées pour une stabilité accrue du réseau TCP/IP. Si le l’anneau est mal cablé ou défecteux, le switch IPGS-3008 indique son état via une LED et envoie un email, trap ou un SMS. Il se reconnecte utomatiquement en cas de coupure de courant. Le Status vous est envoyé par SMS, quand tous les switches sont ré-alimentés. La protéction de boucle, peut aussi éviter les débordements de  « broadcast », si un switch est inséré dans la boucle.</p>
<p><strong><em>User friendly UI; Auto topology drawing*; DMI for dB value</em></strong><br />
The user friendly UI, innovative Auto topology drawing* and topology demo makes IPGS-3008 much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.</p>
<p><strong><em>Enhanced G.8032 Ring &lt; 20ms covering multicast packets for single ring recovery; Enhanced*/basic/auto*/train*mode; MSTP/RSTP</em></strong><br />
Lantech IPGS-3008 features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring*), train ring*, basic ring by easy setup than others. The innovative auto-Ring* configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8 MSTI.</p>
<p><strong><em>DHCP server / client ; DHCP option 82 relay, port based*/Mac based DHCP*; DHCP Option 66*</em></strong><br />
It supports the standard DHCP server/client as well as DHCP option 82 relay. The port based DHCP* distribution can offer the same IP address on port base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The DHCP Option 82 server* offers the convenience of policy setting on the switch. Mac based DHCP server* function binds a fixed IP address and a client Mac address to include dumb switches in DHCP network. It also supports DHCP Option 66*.</p>
<p><strong><em>QoS by VLAN* for legacy device</em></strong><br />
QoS by VLAN* can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p><strong><em>QinQ*, QoS QinQ* and GVRP* supported</em></strong><br />
It supports the QinQ, QoS QinQ, GVRP for large VLAN segmentation.</p>
<p><strong><em>IGMPv3,GMRP*, router port, static multicast forwarding and multicast Ring protection</em></strong><br />
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP*, router port and static multicast forwarding binding by ports for video surveillance application.</p>
<p><strong><em>Exported configuration text file; Factory reset button; CPU watchdog</em></strong><br />
The configuration file of Lantech IPGS-3008 can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. Factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p><strong><em>N-key** for back up, restore configuration and upgrade firmware </em></strong><br />
With N-key**, the configuration file can be mass auto backup, editable restored and auto upgrade firmware for easy maintenance.</p>
<p><strong><em>Relay alarm and email/trap/SMS alerting</em></strong><br />
Featured with relay contact alarm function, the IPGS-3008 is able to connect with alarm system in case of power failure and port disconnection. In case of such event, it will send out email, SMS, trap alerting to predefined users.</p>
<p><strong><em>Dual 12V~48V input with boost technology to 54V PoE output for 12V model, PoE budget 80W</em></strong><br />
Lantech IPGS-3008-12V is designed with dual input power at 9.5V~57VDC while IPGS-3008-48V allows with 44~57VDC input. The PoE budget for 12V input is 80W and for 24V input is 120W.</p>
<p><strong><em>High reliability and extended working temperature</em></strong><br />
Lantech IPGS-3008 provides ±2000V EFT/SURGE and ±6000V contact ESD protection, which can reduce unstable situation caused by power line and Ethernet. It has high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.<br />
The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b436dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Fonction</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div align="right">
<div id="tabs-caracteristique" class="ui-tabs-panel ui-widget-content ui-corner-bottom">
<ul>
<li style="text-align: left;">8 ports cuivre 10/100/1000TX, switch administrable de niveau 2+</li>
<li style="text-align: left;">8 ports injecteurs PoE IEEE802.3at/af, puiisance fournie par port actif : jusqu&#8217;à 30W@54Vin; 15W @48Vin</li>
<li style="text-align: left;">Gamme d&#8217;entrée 9.5V à 57 Vdc pour le modèle 12V, puissance PoE disponible 80W avec une entrée 12V, 120W avec 24V en entrée</li>
<li style="text-align: left;">Gamme d&#8217;entrée 45V à 57 Vdc pour le modèle 48V, puissance PoE disponible 240W</li>
<li style="text-align: left;">taux de commutation: 16 Gbps</li>
<li style="text-align: left;">table d&#8217;adresses MAC 16K</li>
<li style="text-align: left;">trame jumbo 10 Ko pour l&#8217;ensemble des ports</li>
<li style="text-align: left;">protocole standard de gestion d&#8217;anneau ITU G.8032, temps de cicatrisation inférieur à 20 ms pour une toplogie en anneau simple</li>
<li style="text-align: left;">entrée alimentation protégée contre les transitoires en tension, jusqu&#8217;à 2000 Vdc</li>
<li style="text-align: left;">port Ethernet protégé contre les décharges électro-statiques, supporte jusqu&#8217;à 6000 Vdc</li>
<li style="text-align: left;">horloge temps réel intégrée</li>
<li style="text-align: left;">classe de service (CoS) 802.1p, 8 files d&#8217;attente par port</li>
<li style="text-align: left;">IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP</li>
<li style="text-align: left;">Port-Based VLAN, IEEE 802.1Q Tag VLAN, GVRP, Q-in-Q, MVR</li>
<li style="text-align: left;">supporte 802.1ab LLDP, Cisco CDP</li>
<li style="text-align: left;">DHCP Serveur/Client/Option 82</li>
<li style="text-align: left;">mise à jour du microcode via un accès TFTP/HTTPS. Micro-code en redondance pour revenir en mode par défaut usine en cas de défaut de la mise à jour</li>
<li style="text-align: left;">journal d&#8217;événements système, e-mail d&#8217;alertes via serveur SMTP, via SMS, trap SNMP en cas de défauts, RMON (Remote Monitoring)</li>
<li style="text-align: left;">fonctions de sécurité:</li>
<li style="text-align: left;">
<div align="left">
<ul class="style109">
<li class="style99">sécurité au niveau du port: entrée /fltrage adresse MAC</li>
<li class="style99">sécurité au niveau de l&#8217;IP</li>
<li class="style99">sécurité au niveau de l&#8217;authentification: IEEE802.1x/RADIUS</li>
<li class="style99">SSH / SSL</li>
<li class="style99">Validation/Dévalidation Web MMI via Console/Telnet</li>
</ul>
</div>
</li>
<li style="text-align: left;">IGMP v3 et Query  pour les applications multimédia</li>
<li style="text-align: left;">supporte la fonction le routage IGMP dynamique pour les caméras IP non IGMP</li>
<li style="text-align: left;">bouton reset pour retour en configuration usine</li>
<li style="text-align: left;">watchdog intégré</li>
<li style="text-align: left;">fonction de surveillance et d&#8217;alertes (Trap SNMP) de l&#8217;environnement de fonctionnment du switch (température, niveau de tension, charge en courant)</li>
</ul>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1489133547310-939ec51d-aa6e5496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1489133547310-939ec51d-aa6e5496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails Techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h2></h2>
<table border="1" width="540" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td colspan="2"><strong>Normes standards</strong></td>
<td>IEEE802.3 10Base-T Ethernet<br />
IEEE802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z fibre Gigabit<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.1x Authentification (Radius)<br />
IEEE802.1ab LLDP<br />
IEEE 802.3az Efficient Energy Ethernet<br />
IEEE802.3at/af Power over Ethernet</td>
</tr>
<tr>
<td colspan="2"><strong>Capacité de commutation<br />
</strong></td>
<td>16 Gbps</td>
</tr>
<tr>
<td colspan="2"><strong>Unité Centrale</strong></td>
<td>Marwell 1600 MHz, 512 Mo de RAM, 128 Mo de mémoire Flash</td>
</tr>
<tr>
<td colspan="2"><strong>Taux de transfert</strong></td>
<td>Ethernet: 14 880 pps par port<br />
Fast Ethernet: 148 800 pps par port<br />
Gigabit Ethernet: 1,488,000 pps par port</td>
</tr>
<tr>
<td colspan="2"><strong>Table d&#8217;adresses MAC</strong></td>
<td>Capacité 16K</td>
</tr>
<tr>
<td colspan="2"><strong>Trame Jumbo</strong></td>
<td>10240 octets pour l&#8217;ensemble des ports</td>
</tr>
<tr>
<td colspan="2"><strong>Connectique</strong></td>
<td>10/100/1000TX: 8x ports RJ-45 avec fonction auto MDI/MDI-X<br />
Console d&#8217;administration : RS-232 connecteur type RJ-45<br />
Alimentation et relais : bornier à vis 6 points</td>
</tr>
<tr>
<td colspan="2"><strong>Câble réseau</strong></td>
<td>10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td colspan="2"><strong>Protocole</strong></td>
<td>CSMA/CD</td>
</tr>
<tr>
<td colspan="2"><strong>Surveillance des conditions d&#8217;environnement **</strong></td>
<td>Surveillance du niveau de tension et de la température, envoi d&#8217;une notification de défaut</td>
</tr>
<tr>
<td colspan="2"><strong>Température de fonctionnement</strong></td>
<td>-20°C ~ 60°C (modèle standard)<br />
-40°C ~ 75°C (modèle -E)</td>
</tr>
<tr>
<td colspan="2"><strong>Température de stockage</strong></td>
<td>-40°C ~ 85°C</td>
</tr>
<tr>
<td colspan="2"><strong>Alimentation</strong></td>
<td>9.5 Vdc à 57 Vdc pour la version 12 V<br />
44 Vdc à 57 Vdc pour la version 48 V<br />
alimentation avec entrées redondantes<em><br />
</em></td>
</tr>
<tr>
<td colspan="2"><strong>Budget PoE</strong></td>
<td>240W pour une entrée de 44 à 57Vdc (modèle 48V)<br />
80W pour une entrée 12V; 120W pour une entrée  24V(modèle 12V)</td>
</tr>
<tr>
<td colspan="2"><strong>Puissance consommée</strong></td>
<td>10 W</td>
</tr>
<tr>
<td colspan="2"><strong>Dimensions</strong></td>
<td>43 (W) x 105 (D) x 152 (H) mm</td>
</tr>
<tr>
<td colspan="2"><strong>Indice de protection</strong></td>
<td> IP 30</td>
</tr>
<tr>
<td colspan="2"><strong>CEM</strong></td>
<td>FCC Part 15 Class A,<br />
IEC/EN61000-6-2<br />
CE EN55032 Class A<br />
CE EN55024: CE EN61000-4-2 (ESD) Level 3<br />
CE EN61000-4-3 (RS) Level 3<br />
CE EN61000-4-4 (EFT) Level 3<br />
CE EN61000-4-5 ED3 (Surge) Level 3<br />
CE EN61000-4-6 (CS) Level 3<br />
CE EN61000-4-8 (Magnetic field) Level 3</td>
</tr>
<tr>
<td colspan="2"><strong>Chocs et Vibrations</strong></td>
<td>IEC60068-2-32 (chute libre)<br />
IEC60068-2-27 (choc)<br />
IEC60068-2-6 (vibration)</td>
</tr>
<tr>
<td colspan="2"><strong>Fixation</strong></td>
<td>Rail DIN, en option kit de montage sur panneau</td>
</tr>
</tbody>
</table>
<h3 class="panel-title"></h3>
<h2>Caractéristiques logicielles IPGS-3008</h2>
<h3 class="panel-title"></h3>
<table border="1" width="560" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td><strong>Modes d&#8217;administration</strong></td>
<td>SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td><strong>Support MIB<br />
</strong></td>
<td>RFC 1215 Traps MIB*,<br />
RFC 1213 MIBII<br />
RFC 1158 MIBII<br />
RFC 1157 SNMP MIB*,<br />
RFC 1493 Bridge MIB*,<br />
RFC 1573 IF MIB<br />
RFC 2674 VLAN MIB,<br />
Partial RFC 1757 RMON,<br />
RFC 2674 Q-Bridge MIB*; Bridge MIB*,<br />
LLDP MIB*<br />
RSTP MIB*<br />
Private MIB</td>
</tr>
<tr>
<td><strong>ITU G.8032</strong></td>
<td>Version ITU G.8032 v2/2012, autocicatrisation en moins de 20 ms, compatible avec les switches disposant du protocole ITU G.8032</td>
</tr>
<tr>
<td><strong>Port Trunk avec LACP</strong></td>
<td>LACP Port Trunk: 8 groupes/Maximum 10 membres par tronc</td>
</tr>
<tr>
<td><strong>LLDP</strong></td>
<td>Permet au switch de communiquer son identification et caractéristiques</td>
</tr>
<tr>
<td><strong>CDP</strong></td>
<td>Protocole de découverte CISCO pour le mappage réseau</td>
</tr>
<tr>
<td><strong>VLAN</strong></td>
<td>VLAN par port<br />
VLAN à balisage 802.1Q (256 entrées)/ VLAN ID ( VLAN ID de 1 à 4096)<br />
GVRP (256 Groupes)</td>
</tr>
<tr>
<td><strong>IPv6/4</strong></td>
<td>Supporté</td>
</tr>
<tr>
<td><strong>Gestion de boucle</strong></td>
<td>Spanning tree 802.1d et Rapid Spanning Tree 802.1w, Multiple Spanning Tree IEEE802.1s</td>
</tr>
<tr>
<td><strong>Qualité de service<br />
</strong></td>
<td>QoS, service par port, balisage et IPV4, IPv4 Different Service</td>
</tr>
<tr>
<td><strong>Classe de Service<br />
</strong></td>
<td>802.1p, file d&#8217;attente à 8 niveaux de priorité par port</td>
</tr>
<tr>
<td><strong>Mise en miroir de ports<br />
</strong></td>
<td> 3 modes : RX, TX et RX/TX</td>
</tr>
<tr>
<td><strong>IGMP</strong></td>
<td>IGMP snooping v1,v2, v3<br />
diffusion de groupe (256) et requête IGMP</td>
</tr>
<tr>
<td><strong>Sécurité IP</strong></td>
<td>Table de 10 adresses IP autorisées à administrer le switch</td>
</tr>
<tr>
<td><strong>Authentification</strong></td>
<td>IEEE802.1x, RADIUS</td>
</tr>
<tr>
<td><strong>Sécurité du réseau</strong></td>
<td>Accès suivant protocole 802.1x et serveur RADIUS<br />
Association adresses IP et MAC sur les ports (MAC-Poort binding)<br />
Chiffrement SSL et SSH<br />
Liste de contrôle d&#8217;accès (ACL L2/L3)<br />
Interface de gestion WEN accessible en HTTPS</td>
</tr>
<tr>
<td><strong>Filtrage Multidiffusion et IGMP</strong></td>
<td><em>Dynamic:</em><br />
<em>Support IGMP snooping v1, v2,v3 and MLD snooping v1. </em><br />
<em>Support 256 multicast groups</em><br />
<em>Support IGMP and MLD query</em><br />
<em>Support Dynamic IGMP router port for non-IGMP cameria</em><br />
<em>Static: </em><br />
<em>Support 256 static multicast groups</em></td>
</tr>
<tr>
<td><strong>Contrôle de la bande passante</strong></td>
<td>Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td><strong>Journal système<br />
</strong></td>
<td>Enregistrement de l&#8217;activité du système en local et sur serveur distant<em><br />
</em></td>
</tr>
<tr>
<td><strong>Envoi d&#8217;alertes</strong></td>
<td>Serveur SMTP, 8 comptes e-mails, SMS</td>
</tr>
<tr>
<td><strong>Serveur de temps<br />
</strong></td>
<td>Synchronisation avec un serveur de temps sur Internet</td>
</tr>
<tr>
<td><strong>Sortie relais<br />
</strong></td>
<td>sur défauts de connexion et alimentation</td>
</tr>
<tr>
<td><strong>Alerte SNMP</strong></td>
<td>1. démarrage à froid<br />
2. perte de lien<br />
3. défaut d&#8217;authentification<br />
4. modification de la toplogie de l&#8217;anneau<br />
5. défaut d&#8217;alimentation<br />
6. en option, conditions internes d&#8217;environnement anormales</td>
</tr>
<tr>
<td><strong>DHCP</strong></td>
<td>Client, serveur, relais DHCP option 82</td>
</tr>
<tr>
<td><strong>DNS</strong></td>
<td>Fonction DNS client, supporte un serveur DNS primaire et secondaire</td>
</tr>
<tr>
<td><strong>Mise à jour firmware</strong></td>
<td>Transfert de fichier TFTP, sauvegarde et restauration de fichier par TFTP, par HTTP</td>
</tr>
<tr>
<td><strong>Mode de configuration</strong></td>
<td>Fichier au format TX</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div class="col-md-6"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320782574-3b588c5e-ffd46dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Références</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<thead>
<tr>
<th width="10%">P/N</th>
<th width="15%">Model name</th>
<th width="75%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-986</span></td>
<td>IPGS-3008-48V</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input; -20°C to 60°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-987</span></td>
<td>IPGS-3008-48V-E</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-988</span></td>
<td>IPGS-3008-12V</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; <span class="text-highlights text-highlights-red rounded">dual 9.5V~57VDC input</span>; -20°C to 60°C</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-989</span></td>
<td>IPGS-3008-12V-E</td>
<td>8 10/100/1000T w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; <span class="text-highlights text-highlights-red rounded">dual 9.5V~57VDC input</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8850-100</span></td>
<td>N-key Configurator</td>
<td>RJ45 connector dongle for firmware upgrade, auto/editable configuration backup and restoration; -20°C to 60C</td>
</tr>
</tbody>
</table>
<h4>OPTIONAL ACCESSORIES &#8211; DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>NDR-480 Series</td>
<td>480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>NDR-240 Series</td>
<td>240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>NDR-120 Series</td>
<td>120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)</td>
</tr>
<tr>
<td>NDR-75 Series</td>
<td>75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320754302-7b727c18-3cf06dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/D-IPGS-3008.pdf" target="_blank">Datasheet  </a></p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320811737-cd23c365-07206dbc-e4f75496-5562" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Dimensions</span></a></h4></div><div class="vc_tta-panel-body">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2017/08/D-IPGS-3008.png" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/ipgs-3008/">IPGS-3008</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IPES-3416DSFP</title>
		<link>https://www.atevatech.net/fr/ipes-3416dsfp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=ipes-3416dsfp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Sun, 11 Dec 2016 08:40:39 +0000</pubDate>
				<category><![CDATA[Switch POE]]></category>
		<category><![CDATA[Série 3000]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=722</guid>

					<description><![CDATA[<p>IPES-3416DSFP<br />
16 10/100TX PoE at + 4 Dual Speed SFP L2+ Industrial Managed Switch w/ ITU G.8032</p>
The post <a href="https://www.atevatech.net/fr/ipes-3416dsfp/">IPES-3416DSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://www.atevatech.net/wp-content/uploads/2016/12/IPES-3416DSFP.png" width="800" height="471" alt="IPES-3416DSFP" title="ipes-3416dsfp" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="container">
<div class="post-entry post-entry-type-page post-entry-709">
<div class="entry-content-wrapper clearfix">
<div class="flex_column av_one_half flex_column_div av-zero-column-padding first avia-builder-el-0 el_before_av_one_half avia-builder-el-first ">
<section class="av_textblock_section">
<div class="avia_textblock ">
<h4><strong>IPES-3416DSFP</strong></h4>
<h3>16 10/100TX PoE at + 4 Dual Speed SFP L2+ Industrial Managed Switch w/ ITU G.8032</h3>
<ul class="list-unstyled">
<li>Support IEEE802.3at/af up to 30W per port</li>
<li>PoE management incl. Detection and Scheduling</li>
<li>PTP 1588 v2 supported on fiber ports</li>
<li>Enhanced G.8032 ring protection &lt; 20ms with easy configuration; Dynamic coupling ring; Aggregation ring*</li>
<li>Miss-wiring avoidance &amp; Repowered auto ring restore (node failure protection)</li>
<li>User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI</li>
<li>Support LACP link aggregation, IGMP v3/router port, DHCP server &amp; DHCP Option82 for Port&amp;VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, TACAS+*, ACL, IPv6, SMS</li>
<li>Environmental Monitoring for temp., voltage &amp; current**</li>
</ul>
</div>
<div class="avia-content-slider-inner"></div>
</section>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Généralité</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Fonctionalités</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Détails Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Formation</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114"><span class="vc_tta-title-text">Téléchargement</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Généralité</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="tab-id-1-container" class="tab_content active_tab_content">
<div class="tab_inner_content invers-color">
<p>Lantech IPES-3416DSFP is a high performance L2+ (Gigabit uplink) switch with 16 10/100TX + 4 100/1000M SFP w/16 PoE 802.3af/at Injectors which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, enhanced mode for easy configuration and aggregation ring*, comprehensive QoS, QoS by VLAN, advanced security including ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.</p>
<p>Compliant with 802.3af/at standard, the Lantech IPES-3416DSFP is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPES-3416DSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.</p>
<p>Lantech IPES-3416DSFP features hardware-based PTP IEEE1588 v2 function which can allow 4 100/1000 SFP uplinks to synchronize the network with precise accuracy (under 1μs). It has RTC (Real Time Clock) inside that can keep track of current time.</p>
<p>The IPES-3416DSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-3416DSFP is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.</p>
<p>DHCP option 82 and relay agent function (port&amp;vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of police setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.</p>
<p>The user friendly UI, innovative auto topology drawing and topology demo makes IPES-3416DSFP much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IPES-3416DSFP supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.</p>
<p>Lantech IPES-3416DSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for ring/chain topologies which covers dynamic coupling ring &amp; aggregation ring* protection. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. The enhanced mode and dynamic coupling mode ring configuration have never been easier. It supports MSTP that allows RSTP over Vlan for redundant links. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.</p>
<p>The configuration file of Lantech IPES-3416DSFP can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead. The USB slot allows user to backup/ restore configuration.</p>
<p>QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p>The IPES-3416DSFP DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-3416DSFP will immediately send an email &amp; SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.</p>
<p>The optional environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.</p>
<p>The Lantech IPES-3416DSFP is designed with dual power supply at 48VDC. Featured with relay contact alarm function, the IPES-3416DSFP is able to connect with alarm system in case of power failure. The IPES-3416DSFP also provides ±4000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.</p>
<p>Lantech IPES-3416DSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.</p>
<p>The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Fonctionalités</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="main_color container_wrap_first container_wrap fullsize">
<div class="container">
<div class="post-entry post-entry-type-page post-entry-709">
<div class="entry-content-wrapper clearfix">
<div class="tabcontainer top_tab avia-builder-el-11 el_after_av_hr avia-builder-el-last ">
<section class="av_tab_section">
<div id="tab-id-2-container" class="tab_content active_tab_content">
<div class="tab_inner_content invers-color">
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>16 10/100TX + 4 100/1000M SFP w/16 PoE 802.3af/at Injectors (Total 20 Ports Switch)</li>
<li>Embedded 16 PoE Injectors IEEE802.3af/at function to feed power up to 30W@54V; 15W @ 48V per port for active operation</li>
<li>PoE management including PoE detection and scheduling for PD (power devices)</li>
<li>IEEE 1588 PTP v2 (under 1μs) on fiber ports</li>
<li>Back-plane (Switching Fabric): 11.2Gbps</li>
<li>16K MAC address table</li>
<li>DDM to support SFP diagnostic function***
<ul>
<li>Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance</li>
</ul>
</li>
<li>9KB Jumbo frame supported on all ports</li>
<li>User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting</li>
<li>Enhanced G.8032 Ring protection in 20ms &lt; 256 switches
<ul>
<li>Support various ring/chain topologies, including dynamic coupling ring&amp; aggregation ring*</li>
<li>Enhanced G.8032 ring configuration with ease</li>
<li>Auto ring configuration(auto mode) for single ring</li>
<li>Co-exist with RSTP on different ports</li>
</ul>
</li>
<li>Aggregation ring for ring redundancy and bandwidth combination*</li>
<li>Provides EFT protection ±4000 VDC for power line.</li>
<li>Supports ±6000 VDC Ethernet ESD protection</li>
<li>LACP load balancing to distribute the load*</li>
<li>Built-in RTC (Real Time Clock) to keep track of time</li>
<li>Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority</li>
<li>IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy</li>
<li>4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*</li>
<li>Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**</li>
<li>DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server for Port&amp;Vlan based DHCP distribution</li>
<li>Mac based DHCP server to assign IP address that includes dumb switches in DHCP network</li>
<li>Bandwidth Control
<ul>
<li>Ingress packet filter and egress rate limit</li>
<li>Broadcast/multicast packet filter control</li>
</ul>
</li>
<li>Relay alarm output system events</li>
<li>Miss-wiring avoidance
<ul>
<li>LED indicator</li>
<li>Email, traps, or SMS notification</li>
</ul>
</li>
<li>Repowered auto ring restore
<ul>
<li>Ensure the switches in a ring to survive after power breakout is back</li>
<li>The status can be shown in NMS when each switch is back</li>
</ul>
</li>
<li>TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade; USB for auto restore/backup</li>
<li>System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters</li>
<li>Security
<ul>
<li>SSL/SSH/ACL L2&amp;L3</li>
<li>Port Security: MAC address entries/Filter/MAC-Port binding</li>
<li>IP Security: IP address security management to prevent unauthorized intruder.</li>
<li>Management access control with priority</li>
<li>Login Security: IEEE802.1X/RADIUS</li>
<li>HTTPS for secure access to the web interface</li>
</ul>
</li>
<li>Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application</li>
<li>Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow</li>
<li>Multicast VLAN registration* for metro video</li>
<li>IGMPv1,v2,v3 with Query mode for multi media; GMRP**</li>
<li>Factory reset button to restore setting to factory default</li>
<li>Watchdog design to auto reboot switch CPU is found dead</li>
<li>Optional environmental monitoring for system input voltage, current, ambient temperature</li>
<li>Supports DIDO (Digital Input/Digital Output)</li>
<li>IP30 metal housing with DIN rail and Wall-mount** design</li>
</ul>
</li>
</ul>
</li>
</ul>
<div align="right"></div>
</div>
</div>
</section>
<section class="av_tab_section">
<div id="tab-id-3-container" class="tab_content ">
<div class="tab_inner_content invers-color">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading"></div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<table class="table table-striped">
<tbody>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading"></div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
</tbody>
</table>
</div>
</div>
</td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
<tr>
<td valign="top"></td>
<td valign="top"></td>
</tr>
</tbody>
</table>
</div>
<div align="right"></div>
</div>
</div>
</section>
<section class="av_tab_section">
<div id="tab-id-4-container" class="tab_content ">
<div class="tab_inner_content invers-color">
<table class="table table-striped">
<thead>
<tr>
<th width="10%"></th>
<th width="15%"></th>
<th width="75%"></th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<table class="table table-striped">
<thead>
<tr>
<th width="10%"></th>
<th width="90%"></th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<table class="table table-striped">
<thead>
<tr>
<th width="10%"></th>
<th width="40%"></th>
<th width="10%"></th>
<th width="40%"></th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<table class="table table-striped">
<thead>
<tr>
<th width="20%"></th>
<th width="80%"></th>
</tr>
</thead>
<tbody>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
</div>
</div>
</section>
</div>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails Techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="panel-heading">
<p class="panel-title"><strong>Hardware Specifications</strong></p>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Standards</td>
<td valign="top">IEEE 802.3 10Base-T Ethernet<br />
IEEE 802.3u 100Base-TX<br />
IEEE802.3z Gigabit fiber<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1s Multiple Spanning Tree<br />
IEEE 802.3ad Link Aggregation Control Protocol (LACP)<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE 802.1X User Authentication (Radius)<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag<br />
IEEE802.3at/af Power over Ethernet</td>
</tr>
<tr>
<td valign="top">Switch Architecture</td>
<td valign="top">Back-plane (Switching Fabric): 11.2Gbps<br />
Packet throughput ability (Full-Duplex): 23.8Mpps @64bytes</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port<br />
1,488,000pps for Gigabit Fiber Ethernet port</td>
</tr>
<tr>
<td valign="top">CPU</td>
<td valign="top">Marvell 800Mhz</td>
</tr>
<tr>
<td valign="top">RAM</td>
<td valign="top">256M Byte</td>
</tr>
<tr>
<td valign="top">Flash</td>
<td valign="top">128M Byte</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Jumbo frame</td>
<td valign="top">9KB on all ports</td>
</tr>
<tr>
<td valign="top">Connectors</td>
<td valign="top">10/100TX: 16 x ports RJ-45 with Auto MDI/MDI-X function<br />
Mini-GBIC: 4 x 100/1000 SFP socket with DDM<br />
RS-232 connector: RJ-45 type<br />
Power &amp; P-Fail connector: 1 x 6-pole terminal block<br />
DIDO : 1 x 6-pole terminal block</td>
</tr>
<tr>
<td valign="top">Network Cable</td>
<td valign="top">10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td valign="top">Optical Cable</td>
<td valign="top"><strong>1.25Gbps:</strong><br />
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)<br />
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)<br />
<strong>125Mbps:</strong><br />
Multi mode: 0 to 2 km/ 5 km, 1310 nm (62.5/125 μm)<br />
Single mode: 0 to 30 km, 1310 nm (62.5/125 μm)<br />
<strong>WDM 1.25Gbps:</strong><br />
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)<br />
<strong>WDM 125Mbps:</strong><br />
Single mode: 0 to 20 km/ 40 km/ 60 km/ 80 km, 1310 nm (9/125 μm); 0 to 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)</td>
</tr>
<tr>
<td valign="top">Protocol</td>
<td valign="top">CSMA/CD</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red)<br />
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)</td>
</tr>
<tr>
<td valign="top">DI/DO</td>
<td valign="top">2 Digital Input (DI) :<br />
Level 0: -30~2V / Level 1: 10~30V<br />
Max. input current:8mA<br />
2 Digital Output(DO): Open collector to 40 VDC, 200mA</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% ~ 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-20°C~60°C / -4°F~140°F (Standard model)<br />
-40°C~75°C / -40°F~167°F(-E model)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C~85°C / -40°F~185°F</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">48VDC</td>
</tr>
<tr>
<td valign="top">PoE Budget</td>
<td valign="top">480W for 45~56V input<br />
(55V input is recommended for 802.3at 30W applications)<br />
120W for 802.3af 48V input</td>
</tr>
<tr>
<td valign="top">PoE pin assignment</td>
<td valign="top">RJ-45 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. Per port provides 30W at 54~56VDC/15W at 48V~56VDC.<br />
Positive (VCC+): RJ-45 pin 1,2.<br />
Negative (VCC-): RJ-45 pin 3,6.</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">10W</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Metal case. IP-30,<br />
74 (W) x 135 (D) x 152 (H) mm</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">1000 g</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">DIN Rail and Wall Mount** Design</td>
</tr>
<tr>
<td valign="top">EMI &amp; EMS</td>
<td valign="top">FCC Class A,<br />
CE EN61000-6-2, CE EN61000-6-4, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock),<br />
IEC60068-2-6 (Vibration)</td>
</tr>
<tr>
<td valign="top">MTBF</td>
<td valign="top">NA</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<div class="panel-heading">
<h3 class="panel-title">Software Specifications</h3>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Management</td>
<td valign="top">SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td valign="top">SNMP MIB</td>
<td valign="top">RFC 1215 Traps MIB,<br />
RFC 1213 MIBII<br />
RFC 1158 MIBII<br />
RFC 1157 SNMP MIB,<br />
RFC 1493 Bridge MIB,<br />
RFC 1573 IF MIB<br />
RFC 2674 VLAN MIB,<br />
Partial RFC 1643 EtherLike,<br />
Partial RFC 1757 RMON,<br />
RFC 2674 Q-Bridge MIB; Bridge MIB,<br />
RFC 2790 Host Resource MIB<br />
LLDP MIB*<br />
RSTP MIB*<br />
Private MIB</td>
</tr>
<tr>
<td valign="top">ITU G.8032</td>
<td valign="top">Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)<br />
Support various ring/chain topologies<br />
Includes dynamic coupling ring &amp; aggregation ring*<br />
Enhanced G.8032 ring configuration with ease<br />
Co-exist with RSTP on different ports</td>
</tr>
<tr>
<td valign="top">PTP v2</td>
<td valign="top">Support hardware-based IEEE1588 PTPv2 in 1μs with 4 Dual Speed SFP</td>
</tr>
<tr>
<td valign="top">PoE Management</td>
<td valign="top">
<ol>
<li>PoE Detection to check if PD is hang up then restart the PD</li>
<li>PoE Scheduling to On/OFF PD upon routine time table</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Per Port PoE Status</td>
<td valign="top">On/ Off, voltage, current, watts, temperature</td>
</tr>
<tr>
<td valign="top">User friendly UI</td>
<td valign="top">
<ol>
<li>Auto topology drawing</li>
<li>Topology demo</li>
<li>Auto configuration for G.8032(auto mode) for single ring</li>
<li>DDM threshold monitoring with dB values***</li>
<li>Complete CLI for professional setting</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Port Trunk with LACP</td>
<td valign="top">LACP Port Trunk: 8 Trunk groups/Maximum 16 trunk members<br />
Aggregation ring for ring redundancy and bandwidth combination*</td>
</tr>
<tr>
<td valign="top">LLDP</td>
<td valign="top">Supports LLDP to allow switch to advise its identification and capability on the LAN</td>
</tr>
<tr>
<td valign="top">CDP</td>
<td valign="top">Cisco Discovery Protocol for topology mapping</td>
</tr>
<tr>
<td valign="top">Environmental Monitoring**</td>
<td valign="top">System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models)</td>
</tr>
<tr>
<td valign="top">VLAN</td>
<td valign="top">Port Based VLAN<br />
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)<br />
GVRP(256 groups)**, QinQ</td>
</tr>
<tr>
<td valign="top">IPv6/4</td>
<td valign="top">Present</td>
</tr>
<tr>
<td valign="top">Spanning Tree</td>
<td valign="top">Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree</td>
</tr>
<tr>
<td valign="top">Quality of Service</td>
<td valign="top">The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points – DSCP</td>
</tr>
<tr>
<td valign="top">Class of Service</td>
<td valign="top">Support IEEE802.1p class of service, per port provides 8 priority queues</td>
</tr>
<tr>
<td valign="top">QoS by VLAN</td>
<td valign="top">Tagged QoS by VLAN for all devices in the network</td>
</tr>
<tr>
<td valign="top">Login Security</td>
<td valign="top">Supports IEEE802.1X Authentication/RADIUS</td>
</tr>
<tr>
<td valign="top">Port Mirror</td>
<td valign="top">Support 3 mirroring types: “RX, TX and Both packet”</td>
</tr>
<tr>
<td valign="top">Network Security</td>
<td valign="top">Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.<br />
802.1X access control for port based and MAC based authentication/MAC-Port binding<br />
Management access control with priority<br />
256 Policy based Access Control List<br />
SSL/ SSH for Management<br />
HTTPS for secure access to the web interface<br />
TACACS+ for Management Authentication*</td>
</tr>
<tr>
<td valign="top">IGMP</td>
<td valign="top">Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP**</td>
</tr>
<tr>
<td valign="top">MVR</td>
<td valign="top">Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application</td>
</tr>
<tr>
<td valign="top">Bandwidth Control</td>
<td valign="top">Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td valign="top">RTC</td>
<td valign="top">Built-in Real Time Clock to keep track of time always</td>
</tr>
<tr>
<td valign="top">Flow Control</td>
<td valign="top">Supports Flow Control for Full-duplex and Back Pressure for Half-duplex</td>
</tr>
<tr>
<td valign="top">System Log</td>
<td valign="top">Supports System log record and remote system log server</td>
</tr>
<tr>
<td valign="top">SMTP/Text SMS</td>
<td valign="top">Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile</td>
</tr>
<tr>
<td valign="top">Relay Alarm</td>
<td valign="top">Provides one relay output for port breakdown, power fail and alarm.<br />
Alarm Relay current carry ability: 1A @ DC24V</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">
<ol>
<li>Miss-wiring avoidance</li>
<li>Repowered auto ring restore</li>
<li>Loop protection</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">SNMP Trap</td>
<td valign="top">Up to 10 trap stations; trap types including:</p>
<ol>
<li>Device cold start</li>
<li>Authorization failure</li>
<li>Port link up/link down</li>
<li>DI/DO open/close</li>
<li>Typology change(ITU ring)</li>
<li>PoE ping failure</li>
<li>Power failure</li>
<li>Environmental abnormal**</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">DHCP</td>
<td valign="top">Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&amp;VLAN based DHCP distribution (DHCP relay agent)</td>
</tr>
<tr>
<td valign="top">Mac based DHCP Server</td>
<td valign="top">Assign IP address by Mac that can include dumb switch in DHCP network</td>
</tr>
<tr>
<td valign="top">DNS</td>
<td valign="top">Provide DNS client feature and support Primary and Secondary DNS server.</td>
</tr>
<tr>
<td valign="top">SNTP</td>
<td valign="top">Supports SNTP to synchronize system clock in Internet</td>
</tr>
<tr>
<td valign="top">Firmware Update</td>
<td valign="top">Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade</td>
</tr>
<tr>
<td valign="top">Configuration<br />
upload and download</td>
<td valign="top">Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default; USB for auto restore/backup</td>
</tr>
<tr>
<td valign="top">IfAlias</td>
<td valign="top">Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface</td>
</tr>
</tbody>
</table>
</div>
</div>
</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<thead>
<tr>
<th width="10%">P/N</th>
<th width="15%">Model name</th>
<th width="75%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-796</span></td>
<td>IPES-3416DSFP</td>
<td>16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; -20°C to 60°C; 48VDC</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-797</span></td>
<td>IPES-3416DSFP-E</td>
<td>16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; 48VDC</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-798</span></td>
<td>IPES-3416DSFP-M</td>
<td>16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; -20°C to 60°C; 48VDC</td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-799</span></td>
<td>IPES-3416DSFP-M-E</td>
<td>16 10/100TX PoE at/af up to 30W + 4 Dual Speed SFP L2+ Managed Industrial PoE Switch; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; 48VDC</td>
</tr>
</tbody>
</table>
<p><strong>OPTIONAL ACCESSORIES – 55VDC DIN Rail Power for 802.3at Applications</strong></p>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1240-48S-5</td>
<td>48~56VDC, 4.3A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1360-48S-5</td>
<td>48~56VDC, 6.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1500-48S-5</td>
<td>48~56VDC, 9A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>
<p><strong>OPTIONAL ACCESSORIES – Mini GBIC (SFP)</strong></p>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="40%">Description</th>
<th width="10%">Model name</th>
<th width="40%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>8330-162</td>
<td>MINI GBIC 1000SX (LC/0.5km) Transceiver</td>
<td>8330-188</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-163</td>
<td>MINI GBIC 1000SX2 (LC/2km) Transceiver</td>
<td>8330-189</td>
<td>LTSFP-1000BX-10KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-165</td>
<td>MINI GBIC 1000LX (LC/10km) Transceiver</td>
<td>8330-186</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8340-0591</td>
<td>MINI GBIC 1000LHX (LC/40km) Transceiver</td>
<td>8330-187</td>
<td>LTSFP-1000BX-20KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-166</td>
<td>MINI GBIC 1000XD (LC/50km) Transceiver</td>
<td>8330-180</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-169</td>
<td>MINI GBIC 1000XD (LC/60km) Transceiver</td>
<td>8330-182</td>
<td>LTSFP-1000BX-40KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-167</td>
<td>MINI GBIC 1000ZX (LC/80km) Transceiver</td>
<td>8330-181</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1310)</td>
</tr>
<tr>
<td>8330-170</td>
<td>MINI GBIC 1000EZX (120km) Transceiver</td>
<td>8330-183</td>
<td>LTSFP-1000BX-60KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-060</td>
<td>100Base FX 2KM, Multi-mode, LC Transceiver</td>
<td>8330-184</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1490)</td>
</tr>
<tr>
<td>8330-065</td>
<td>100Base FX 5KM, Multi-mode, LC Transceiver</td>
<td>8330-185</td>
<td>LTSFP-1000BX-80KM Transceiver (WDM 1550)</td>
</tr>
<tr>
<td>8330-061</td>
<td>100Base LX 30KM, Single-mode, LC Transceiver</td>
<td>8330-168</td>
<td>MINI GBIC 1000T (100m) Transceiver</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Formations disponibles sur la configuration des switches et les réseaux TCP/IP</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f4827230-3bc500d2-6c6df552-7114" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Brochure</p>
<p><a href="https://www.atevatech.net/wp-content/uploads/2016/12/M-IPES_IES-3416DSFP.pdf">Manuel utilisateur</a></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/ipes-3416dsfp/">IPES-3416DSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IGS-3408DSFP</title>
		<link>https://www.atevatech.net/fr/igs-3408dsfp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=igs-3408dsfp</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 13:43:55 +0000</pubDate>
				<category><![CDATA[LANTECH]]></category>
		<category><![CDATA[Série 3000]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=380</guid>

					<description><![CDATA[<p>IGS-3408DSFP<br />
8 10/100/1000T + 4 100/1000M SFP L2+ Industrial Managed Switch w/PTP V2</p>
The post <a href="https://www.atevatech.net/fr/igs-3408dsfp/">IGS-3408DSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2><strong>IGS-3408DSFP : Switch LANTECH managed<br />
</strong></h2>
<h3>8 10/100/1000T + 4 100/1000M SFP L2+ Industrial Managed Switch w/PTP V2</h3>

		</div>
	</div>
<div class="vc_separator wpb_content_element vc_separator_align_center vc_sep_width_50 vc_sep_pos_align_left vc_separator_no_text vc_sep_color_grey wpb_content_element  wpb_content_element" ><span class="vc_sep_holder vc_sep_holder_l"><span class="vc_sep_line"></span></span><span class="vc_sep_holder vc_sep_holder_r"><span class="vc_sep_line"></span></span>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://www.atevatech.net/wp-content/uploads/2016/10/IGS-3408DSFP-200x200.png" width="200" height="200" alt="IGS-3408DSFP" title="igs-3408dsfp" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>IGS-3804DSFP : Switch LANTECH manageable</p>
<ul>
<li></li>
<li><span class="color-green"><strong>Support PTPv2 two-step transparent clock @ all ports</strong></span></li>
<li><i class="fa fa-check color-green"></i> Enhanced G.8032 ring protection &lt; 20ms with auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP</li>
<li><i class="fa fa-check color-green"></i> Miss-wiring avoidance &amp; Repowered auto ring restore (node failure protection)</li>
<li><i class="fa fa-check color-green"></i> User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***; Complete CLI</li>
<li><i class="fa fa-check color-green"></i> Support LACP link aggregation, IGMP v3/router port, DHCP server &amp; DHCP Option82 for Port&amp;VLAN based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, ACL, IPv6, SMS</li>
<li><i class="fa fa-check color-green"></i> Environmental Monitoring for temp., voltage &amp; current**</li>
</ul>
<p>&nbsp;</p>
<p><img decoding="async" class="alignnone wp-image-396" src="https://www.atevatech.net/wp-content/uploads/2016/10/rohs-300x300.png" alt="rohs" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/rohs-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/rohs-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/rohs-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/rohs-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/rohs.png 60w" sizes="(max-width: 50px) 100vw, 50px" /><img decoding="async" class="alignnone wp-image-393" src="https://www.atevatech.net/wp-content/uploads/2016/10/fcc-300x300.png" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/fcc-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/fcc-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/fcc-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/fcc-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/fcc.png 60w" sizes="(max-width: 50px) 100vw, 50px" /><img decoding="async" class="alignnone wp-image-391" src="https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-300x300.png" alt="itu-ring" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring.png 60w" sizes="(max-width: 50px) 100vw, 50px" /><img loading="lazy" decoding="async" class="alignnone wp-image-390" title="Support protocol PTPv2" src="https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2-300x300.png" alt="ptp-v2" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/ptp-v2.png 60w" sizes="auto, (max-width: 50px) 100vw, 50px" /><img loading="lazy" decoding="async" class="alignnone wp-image-392" src="https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring-300x300.png" alt="e-monitoring" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/e-monitoring.png 60w" sizes="auto, (max-width: 50px) 100vw, 50px" /><img decoding="async" class="alignnone wp-image-391" src="https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-300x300.png" alt="itu-ring" width="50" height="50" srcset="https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-300x300.png 300w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-150x150.png 150w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-768x768.png 768w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring-1024x1024.png 1024w, https://www.atevatech.net/wp-content/uploads/2016/10/itu-ring.png 60w" sizes="(max-width: 50px) 100vw, 50px" /></p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f482"><span class="vc_tta-title-text">Aperçu</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f482"><span class="vc_tta-title-text">Détails techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00a1d8c-f482"><span class="vc_tta-title-text">Spécificité</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00a1d8c-f482"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a7618ced-e00a1d8c-f482"><span class="vc_tta-title-text">Formation</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f482" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849265730-47f8c569-3a1d8ced-e00a1d8c-f482"><span class="vc_tta-title-text">Téléchargement</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Aperçu</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h4>OVERVIEW</h4>
<p>Lantech IGS-3408DSFP is a high performance L2+ (Gigabit uplink) switch with 8 10/100/1000T + 4 1000M SFP which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, enhanced mode for easy configuration and aggregation ring*, comprehensive QoS, QoS by VLAN, advanced security including ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.</p>
<p>&nbsp;</p>
<p>Lantech IGS-3408DSFP features hardware-based PTP IEEE1588 v2 two-step function which can allow 8 10/100/1000T and 4 100/1000 SFP uplinks to synchronize the network with precise accuracy (under 1μs). It has RTC (Real Time Clock) inside that can keep track of current time.</p>
<p>&nbsp;</p>
<p>The IGS-3408DSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IGS-3408DSFP is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.</p>
<p>&nbsp;</p>
<p>DHCP option 82 and relay agent function (port&amp;vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.</p>
<p>&nbsp;</p>
<p>The user friendly UI, innovative auto topology drawing and topology demo makes IGS-3408DSFP much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IGS-3408DSFP supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.</p>
<p>&nbsp;</p>
<p>Lantech IGS-3408DSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 16 MSTI. The ITU G.8032 Ring and RSTP can be co-existed in the same switch with different ports for the most flexible protection.</p>
<p>&nbsp;</p>
<p>The configuration file of Lantech IGS-3408DSFP can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.</p>
<p>&nbsp;</p>
<p>QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.</p>
<p>&nbsp;</p>
<p>The IGS-3408DSFP DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IGS-3408DSFP will immediately send an email &amp; SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.</p>
<p>&nbsp;</p>
<p>The optional environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.</p>
<p>&nbsp;</p>
<p>The Lantech IGS-3408DSFP is designed with dual power supply at 24/48VDC or single power supply at 90~305VAC/120~430VDC. Featured with relay contact alarm function, the IGS-3408DSFP is able to connect with alarm system in case of power failure. The IGS-3408DSFP also provides ±4000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.</p>
<p>&nbsp;</p>
<p>Lantech IGS-3408DSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.</p>
<p>&nbsp;</p>
<p>The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>8 10/100/1000T + 4 1000M SFP (Total 12 Ports Switch)</li>
<li>IEEE 1588 PTP v2 two-step (under 1μs)</li>
<li>Back-plane (Switching Fabric): 24Gbps</li>
<li>16K MAC address table</li>
<li>DDM to support SFP diagnostic function***
<ul>
<li>Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance</li>
</ul>
</li>
<li>9KB Jumbo frame supported on all ports</li>
<li>User friendly UI, auto topology drawing, topology demo, complete CLI for professional setting</li>
<li>Enhanced G.8032 Ring protection in 20ms &lt; 256 switches
<ul>
<li>Support various ring/chain topologies, including dynamic coupling ring&amp; aggregation ring*</li>
<li>Enhanced G.8032 ring configuration with ease</li>
<li>Auto ring configuration(auto mode) for single ring</li>
<li>Co-exist with RSTP on different ports</li>
</ul>
</li>
<li>Aggregation ring for ring redundancy and bandwidth combination*</li>
<li>Dual DC input from 18V~57VDC, HV model with single 90~305VAC or 120~430VDC power input</li>
<li>Provides EFT protection ±4000 VDC for power line.</li>
<li>Supports ±6000 VDC Ethernet ESD protection</li>
<li>LACP load balancing to distribute the load*</li>
<li>Built-in RTC (Real Time Clock) to keep track of time</li>
<li>Supports IEEE 802.1p Class of Service, per port provides 8 priority queues Port base, Tag Base and Type of Service Priority</li>
<li>IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP VLAN redundancy</li>
<li>4K 802.1Q VLAN, Port based VLAN, GVRP**, QinQ*</li>
<li>Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info can be viewed via Web/ Console/ LantechTM InstaConfig**/ LantechTM InstaView**</li>
<li>DHCP server / client / Port&amp;Vlan based DHCP distribution / DHCP Option 82 supported</li>
<li>Mac based DHCP server to assign IP address that includes dumb switches in DHCP network</li>
<li>Bandwidth Control
<ul>
<li>Ingress packet filter and egress rate limit</li>
<li>Broadcast/multicast packet filter control</li>
</ul>
</li>
<li>Relay alarm output system events</li>
<li>Miss-wiring avoidance
<ul>
<li>LED indicator</li>
<li>Email, traps, or SMS notification</li>
</ul>
</li>
<li>Repowered auto ring restore
<ul>
<li>Ensure the switches in a ring to survive after power breakout is back</li>
<li>The status can be shown in NMS when each switch is back</li>
</ul>
</li>
<li>TFTP/HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade</li>
<li>System Event Log, SMTP Email alert, SMS mobile (text) and SNMP Trap for alarm support; 32 RMON counters</li>
<li>Security
<ul>
<li>SSL/SSH/ACL L2&amp;L3</li>
<li>Port Security: MAC address entries/Filter/MAC-Port binding</li>
<li>IP Security: IP address security management to prevent unauthorized intruder.</li>
<li>Management access control with priority</li>
<li>Login Security: IEEE802.1X/RADIUS</li>
<li>HTTPS for secure access to the web interface</li>
</ul>
</li>
<li>Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application</li>
<li>Multicast static route for non- IGMP camera to prevent flooding; IGMP router port to assign query in ring and for reversed multicast video flow</li>
<li>Multicast VLAN registration* for metro video</li>
<li>IGMPv1,v2,v3 with Query mode for multi media; GMRP**</li>
<li>Factory reset button to restore setting to factory default</li>
<li>Watchdog design to auto reboot switch CPU is found dead</li>
<li>Optional environmental monitoring for system input voltage, current, ambient temperature</li>
<li>Supports DIDO (Digital Input/Digital Output)</li>
<li>IP30 metal housing with DIN rail and Wall-mount** design</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Spécificité</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="panel-heading">
<h3 class="panel-title">Hardware Specifications</h3>
<p>&nbsp;</p>
</div>
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Standards</td>
<td valign="top">IEEE 802.3 10Base-T Ethernet<br />
IEEE 802.3u 100Base-TX<br />
IEEE802.3ab 1000Base-T<br />
IEEE802.3z Gigabit fiber<br />
IEEE802.3x Flow Control and Back Pressure<br />
IEEE802.3ad Port trunk with LACP<br />
IEEE802.1d Spanning Tree<br />
IEEE802.1w Rapid Spanning Tree<br />
IEEE802.1s Multiple Spanning Tree<br />
IEEE 802.3ad Link Aggregation Control Protocol (LACP)<br />
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />
IEEE 802.1X User Authentication (Radius)<br />
IEEE802.1p Class of Service<br />
IEEE802.1Q VLAN Tag</td>
</tr>
<tr>
<td valign="top">Switch Architecture</td>
<td valign="top">Back-plane (Switching Fabric): 24Gbps</td>
</tr>
<tr>
<td valign="top">Transfer Rate</td>
<td valign="top">14,880pps for Ethernet port<br />
148,800pps for Fast Ethernet port<br />
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port</td>
</tr>
<tr>
<td valign="top">CPU</td>
<td valign="top">Marvell 800Mhz</td>
</tr>
<tr>
<td valign="top">RAM</td>
<td valign="top">256M Byte</td>
</tr>
<tr>
<td valign="top">Flash</td>
<td valign="top">128M Byte</td>
</tr>
<tr>
<td valign="top">Mac Address</td>
<td valign="top">16K MAC address table</td>
</tr>
<tr>
<td valign="top">Jumbo frame</td>
<td valign="top">9KB on all ports</td>
</tr>
<tr>
<td valign="top">Connectors</td>
<td valign="top">10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function<br />
Mini-GBIC: 4 x 100/1000 SFP socket with DDM<br />
RS-232 connector: RJ-45 type<br />
Power &amp; P-Fail connector: 1 x 6-pole terminal block<br />
DIDO : 1 x 6-pole terminal block</td>
</tr>
<tr>
<td valign="top">Network Cable</td>
<td valign="top">10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)<br />
1000Base-T: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable<br />
EIA/TIA-568 100-ohm (100m)</td>
</tr>
<tr>
<td valign="top">Optical Cable</td>
<td valign="top"><strong>1.25Gbps:</strong><br />
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)<br />
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)<br />
<strong>125Mbps:</strong><br />
Multi mode: 0 to 2 km/ 5 km, 1310 nm (62.5/125 μm)<br />
Single mode: 0 to 30 km, 1310 nm (62.5/125 μm)<br />
<strong>WDM 1.25Gbps:</strong><br />
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)<br />
<strong>WDM 125Mbps:</strong><br />
Single mode: 0 to 20 km/ 40 km/ 60 km/ 80 km, 1310 nm (9/125 μm); 0 to 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)</td>
</tr>
<tr>
<td valign="top">Protocol</td>
<td valign="top">CSMA/CD</td>
</tr>
<tr>
<td valign="top">LED</td>
<td valign="top">Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red)<br />
Ethernet port: Link/Activity (Green), Speed (Green); Mini-GBIC: Link/Activity (Green)</td>
</tr>
<tr>
<td valign="top">DI/DO</td>
<td valign="top">2 Digital Input (DI) :<br />
Level 0: -30~2V / Level 1: 10~30V<br />
Max. input current:8mA<br />
2 Digital Output(DO): Open collector to 40 VDC, 200mA</td>
</tr>
<tr>
<td valign="top">Operating Humidity</td>
<td valign="top">5% ~ 95% (Non-condensing)</td>
</tr>
<tr>
<td valign="top">Operating Temperature</td>
<td valign="top">-20°C~60°C / -4°F~140°F (Standard model)<br />
-40°C~75°C / -40°F~167°F(-E model)</td>
</tr>
<tr>
<td valign="top">Storage Temperature</td>
<td valign="top">-40°C~85°C / -40°F~185°F</td>
</tr>
<tr>
<td valign="top">Power Supply</td>
<td valign="top">Dual 18~57VDC (Standard model)<br />
Single 90~305VAC/120~430VDC (HV model)</td>
</tr>
<tr>
<td valign="top">Power Consumption</td>
<td valign="top">10W</td>
</tr>
<tr>
<td valign="top">Case Dimension</td>
<td valign="top">Metal case. IP-30,<br />
74 (W) x 105 (D) x 152 (H) mm (Standard model)<br />
74 (W) x 135 (D) x 152 (H) mm (HV model)</td>
</tr>
<tr>
<td valign="top">Weight</td>
<td valign="top">900 g</td>
</tr>
<tr>
<td valign="top">Installation</td>
<td valign="top">DIN Rail and Wall Mount** Design</td>
</tr>
<tr>
<td valign="top">EMI &amp; EMS</td>
<td valign="top">FCC Class A,<br />
CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11</td>
</tr>
<tr>
<td valign="top">Stability Testing</td>
<td valign="top">IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock),<br />
IEC60068-2-6 (Vibration)</td>
</tr>
<tr>
<td valign="top">MTBF</td>
<td valign="top">NA</td>
</tr>
<tr>
<td valign="top">Warranty</td>
<td valign="top">5 years</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3><i class="fa fa-desktop"></i> Software Specifications</h3>
<div class="col-md-6">
<div class="panel panel-grey margin-bottom-40">
<table class="table table-striped">
<tbody>
<tr>
<td valign="top">Management</td>
<td valign="top">SNMP v1 v2c, v3/ Web/Telnet/CLI</td>
</tr>
<tr>
<td valign="top">SNMP MIB</td>
<td valign="top">RFC 1215 Traps MIB,<br />
RFC 1213 MIBII<br />
RFC 1158 MIBII<br />
RFC 1157 SNMP MIB,<br />
RFC 1493 Bridge MIB,<br />
RFC 1573 IF MIB<br />
RFC 2674 VLAN MIB,<br />
Partial RFC 1643 EtherLike,<br />
Partial RFC 1757 RMON,<br />
RFC 2674 Q-Bridge MIB; Bridge MIB,<br />
RFC 2790 Host Resource MIB<br />
LLDP MIB*<br />
RSTP MIB*<br />
Private MIB</td>
</tr>
<tr>
<td valign="top">ITU G.8032</td>
<td valign="top">Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)<br />
Support various ring/chain topologies<br />
Includes dynamic coupling ring &amp; aggregation ring*<br />
Enhanced G.8032 ring configuration with ease<br />
Co-exist with RSTP on different ports</td>
</tr>
<tr>
<td valign="top">PTP v2</td>
<td valign="top">Support hardware-based IEEE1588 PTPv2 in 1μs, End to End (2-step) and Peer to Peer (2-step) modes in Transparent Clock, with 8 10/100/1000T and 4 100/1000 SFP</td>
</tr>
<tr>
<td valign="top">User friendly UI</td>
<td valign="top">
<ol>
<li>Auto topology drawing</li>
<li>Topology demo</li>
<li>Auto configuration for G.8032(auto mode) for single ring</li>
<li>DDM threshold monitoring with dB values***</li>
<li>Complete CLI for professional setting</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">Port Trunk with LACP</td>
<td valign="top">LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members<br />
Aggregation ring for ring redundancy and bandwidth combination*</td>
</tr>
<tr>
<td valign="top">LLDP</td>
<td valign="top">Supports LLDP to allow switch to advise its identification and capability on the LAN</td>
</tr>
<tr>
<td valign="top">CDP</td>
<td valign="top">Cisco Discovery Protocol for topology mapping</td>
</tr>
<tr>
<td valign="top">Environmental Monitoring**</td>
<td valign="top">System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status(-M models)</td>
</tr>
<tr>
<td valign="top">VLAN</td>
<td valign="top">Port Based VLAN<br />
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)<br />
GVRP(256 groups)**, QinQ*</td>
</tr>
<tr>
<td valign="top">IPv6/4</td>
<td valign="top">Present</td>
</tr>
<tr>
<td valign="top">Spanning Tree</td>
<td valign="top">Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree</td>
</tr>
<tr>
<td valign="top">Quality of Service</td>
<td valign="top">The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points &#8211; DSCP</td>
</tr>
<tr>
<td valign="top">Class of Service</td>
<td valign="top">Support IEEE802.1p class of service, per port provides 8 priority queues</td>
</tr>
<tr>
<td valign="top">QoS by VLAN</td>
<td valign="top">Tagged QoS by VLAN for all devices in the network</td>
</tr>
<tr>
<td valign="top">IP Security</td>
<td valign="top">Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.</td>
</tr>
<tr>
<td valign="top">Login Security</td>
<td valign="top">Supports IEEE802.1X Authentication/RADIUS</td>
</tr>
<tr>
<td valign="top">Port Mirror</td>
<td valign="top">Support 3 mirroring types: “RX, TX and Both packet”</td>
</tr>
<tr>
<td valign="top">Network Security</td>
<td valign="top">Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.<br />
802.1X access control for port based and MAC based authentication/MAC-Port binding<br />
Management access control with priority<br />
256 Policy based Access Control List<br />
SSL/ SSH for Management<br />
HTTPS for secure access to the web interface<br />
TACACS+ for Authentication</td>
</tr>
<tr>
<td valign="top">IGMP</td>
<td valign="top">Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; GMRP**</td>
</tr>
<tr>
<td valign="top">MVR</td>
<td valign="top">Static multicast forwarding forward reversed IGMP flow (MVR) with multicast packets binding with ports for IP surveillance application</td>
</tr>
<tr>
<td valign="top">Bandwidth Control</td>
<td valign="top">Support ingress packet filter and egress packet limit.<br />
The egress rate control supports all of packet type.<br />
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet.<br />
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.</td>
</tr>
<tr>
<td valign="top">RTC</td>
<td valign="top">Built-in Real Time Clock to keep track of time always</td>
</tr>
<tr>
<td valign="top">Flow Control</td>
<td valign="top">Supports Flow Control for Full-duplex and Back Pressure for Half-duplex</td>
</tr>
<tr>
<td valign="top">System Log</td>
<td valign="top">Supports System log record and remote system log server</td>
</tr>
<tr>
<td valign="top">SMTP/Text SMS</td>
<td valign="top">Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile</td>
</tr>
<tr>
<td valign="top">Relay Alarm</td>
<td valign="top">Provides one relay output for port breakdown, power fail and alarm.<br />
Alarm Relay current carry ability: 1A @ DC24V</td>
</tr>
<tr>
<td valign="top">Protection</td>
<td valign="top">
<ol>
<li>Miss-wiring avoidance</li>
<li>Repowered auto ring restore</li>
<li>Loop protection</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">SNMP Trap</td>
<td valign="top">Up to 10 trap stations; trap types including:</p>
<ol>
<li>Device cold start</li>
<li>Authorization failure</li>
<li>Port link up/link down</li>
<li>DI/DO open/close</li>
<li>Typology change(ITU ring)</li>
<li>PoE ping failure</li>
<li>Power failure</li>
<li>Environmental abnormal**</li>
</ol>
</td>
</tr>
<tr>
<td valign="top">DHCP</td>
<td valign="top">Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&amp;VLAN based DHCP distribution (DHCP relay agent)</td>
</tr>
<tr>
<td valign="top">Mac based DHCP Server</td>
<td valign="top">Assign IP address by Mac that can include dumb switch in DHCP network</td>
</tr>
<tr>
<td valign="top">DNS</td>
<td valign="top">Provide DNS client feature and support Primary and Secondary DNS server.</td>
</tr>
<tr>
<td valign="top">SNTP</td>
<td valign="top">Supports SNTP to synchronize system clock in Internet</td>
</tr>
<tr>
<td valign="top">Firmware Update</td>
<td valign="top">Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade; LantechTM InstaConfig** for multiple upgrade</td>
</tr>
<tr>
<td valign="top">Configuration<br />
upload and download</td>
<td valign="top">Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default</td>
</tr>
<tr>
<td valign="top">IfAlias</td>
<td valign="top">Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface</td>
</tr>
</tbody>
</table>
</div>
<div align="right">
<h6>*Future Release<br />
**Optional<br />
***Optional DDM SFP required</h6>
</div>
</div>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="tab-v1"></div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="table table-striped">
<tbody>
<tr>
<td><span class="text-highlights rounded">8350-806</span></td>
<td>IGS-3408DSFP</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-807</span></td>
<td>IGS-3408DSFP-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-808</span></td>
<td>IGS-3408DSFP-M</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-809</span></td>
<td>IGS-3408DSFP-M-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-orange rounded">Dual 24/48VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-853</span></td>
<td>IGS-3408DSFP-HV</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-854</span></td>
<td>IGS-3408DSFP-HV-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-8531</span></td>
<td>IGS-3408DSFP-HV-M</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; -20°C to 60°C; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
<tr>
<td><span class="text-highlights rounded">8350-8541</span></td>
<td>IGS-3408DSFP-HV-M-E</td>
<td>8 10/100/1000T + 4 100/1000M SFP L2+ PTP Managed Industrial Switch; <span class="text-highlights text-highlights-aqua rounded">-40°C to 75°C</span>; <span class="text-highlights text-highlights-green rounded">Environmental monitoring</span>; <span class="text-highlights text-highlights-red rounded">Single 90~305VAC/120~430VDC</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>OPTIONAL ACCESSORIES &#8211; DIN Rail Power</h4>
<table class="table table-striped">
<thead>
<tr>
<th width="10%">Model name</th>
<th width="90%">Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>AD1048-24FS</td>
<td>24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1024-24F</td>
<td>24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)</td>
</tr>
<tr>
<td>AD1240-48S</td>
<td>48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
<tr>
<td>AD1120-48F</td>
<td>48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a7618ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a7618ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Formation disponible sur la parametrisation des Switches L2+</p>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849265730-47f8c569-3a1d8ced-e00a1d8c-f482" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849265730-47f8c569-3a1d8ced-e00a1d8c-f482" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="http://lantechcom.eu/cms/wp-content/uploads/2015/09/D-IGS-3408GSFP.pdf" target="_blank">Brochure</a></p>
<p><a href="https://www.atevatech.net/wp-content/uploads/2016/12/M-3-5-Series-Software-Management.pdf" target="_blank">Manuel utilisateur (Software)</a></p>
<p><a href="https://www.atevatech.net/wp-content/uploads/2016/11/M-IPGS_IGS-3XXX_5XXX_IP30.pdf" target="_blank">Manuel utilisateur ( Hardware )</a></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			
		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/igs-3408dsfp/">IGS-3408DSFP</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
