<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PROFINET Tester | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/fr/category/profinet/profinet-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Tue, 30 Jun 2020 07:27:10 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>PROFINET Tester | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NetXpertXG</title>
		<link>https://www.atevatech.net/fr/netxpertxg/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=netxpertxg</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Tue, 25 Feb 2020 10:04:51 +0000</pubDate>
				<category><![CDATA[ETHERNET-Testeur]]></category>
		<category><![CDATA[PROFINET Tester]]></category>
		<category><![CDATA[SOFTING]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=24764</guid>

					<description><![CDATA[<p>NetXpert XG, testeur et certification de réseaux jusqu'a 10GB/s</p>
The post <a href="https://www.atevatech.net/fr/netxpertxg/">NetXpertXG</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1 class="h1 ">Test vos cables Ethernet et vérifie/garantie la vitesse limite de ces cables.</h1>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2020/02/NetXpoertXG.jpg" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2020/02/Softing_IT_Networks_NetXpert_XG_Reports-300x300.png" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Les vitesses des &#8221; Wireless Access points&#8221; dépassent souvent, les vitesses de cablage installé dans le réseau . Est il possible que vos cables gèrent des vitesses bien au delà de leurs spécifications ? Est il possible que vos cables CAT5e ou CAT6 puissent atteindre des vitesses de 1GBits/S voire 10Gbits/s</p>
<p>Pour le savoir, une simple fonction sur le NetXpert XG, permettent d&#8217;effectuer 3 tests. Effectue un test de vitesse en envoyant 1Gb/s de données via votre cable ( Test BERT ) et il prouvera si celui ci fonctionera au-delà  des spécifications et suivra la vitesse des &#8220;Access Points&#8221; installés</p>
<p>Le NetXpert est le seul testeur de cables et gestionnaire de réseaux actif a effectuer  un test de taux d&#8217;erreurs sur les bits ( BERT ) , un test de signal Signal/bruit ( SNR) et retard de vitesse de 1Gb/s, 5Gb/s ou 10Gb/s en appuyant sur une touche. Vous pouvez maintenant effectuer des tests de débit en temps réel pour valider vos cables jusqu&#8217;à 10Gb/s.</p>
<p>Test le taux d&#8217;erreurs, le bruit et le delai de propagation instantanément</p>
<div class="ce-textpic ce-left ce-above">
<div class="ce-bodytext">
<p>En effectuant un test de taux d&#8217;erreur sur les bits ( BERT ) et selon les normes IEE802.3an, le NetXpert XG vous certifie ou non, une transmission de données sans erreur jusqu&#8217;à 10Gb/s</p>
<p>Test automatique avec une &#8220;touche&#8221; comprends le rapport Signal/bruit ( SNR) et le décalage temporel, qui peuvent avoir un impact significatif sur la transmission Gigabit</p>
<p>Le rapport &#8220;signal/bruit&#8221; vérifie que le bruit est suffisamment faible et que le signal est suffisamment élevé pour une transmission fiable. Le &#8220;delai de propagation&#8221; indique un décalage entre les paires de fils. Un retard excessif peut entrainer un sérieuse dégradation de la transmission et donc de la performance.</p>
<p>Les 3 mesures fondamentales pour déterminer si une transmission est fiable ou non, peuvent être effectuées à l&#8217;aide d&#8217;une seule touche. La mesure faite, vous pouvez réitérer immédiatement à l&#8217;aide de cette unique fonction. Chaque mesure est archivée et est fournis à un rapport de synthèse final au format PDF, CVS ou XML</p>
</div>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecb6a44-34e9" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecb6a44-34e9"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b436a44-34e9" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b436a44-34e9"><span class="vc_tta-title-text">Details Techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#Downloads" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-Downloads"><span class="vc_tta-title-text">Téléchargement</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#references" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-references"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecb6a44-34e9" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecb6a44-34e9" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2 class="h2">The <strong>cable qualifier </strong>that is defining a new category &#8212; the <strong>cable project qualifier</strong></h2>
<p>If you are a cable installer, network owner, network builder, or system integrator, you&#8217;ll be excited to hear that NetXpert XG includes a project editor and auto test generator for up to 1000 cables, and test reports you can keep for your records or leave with your customer.  Once the tests are created, plug in the cable, click test, and NetXpert XG starts testing the cable to IEEE 802.3 standards to prove the speed of your cable.  Not only do you get a wiremap and cable length, NetXpert XG tests BERT, SNR, Delay Skew, distance to opens, shorts, or miswires.  As a bonus you get active network tests for copper, fiber, and wireless.  And, with 2 NetXpert XG local units, you can test fiber cables.</p>
<header>
<h2 class="h2 ">Cable Project Qualifier</h2>
</header>
<div class="ce-textpic ce-left ce-above">
<div class="ce-bodytext">
<ul class="default-list">
<li>Use the project editor, cable test editor, test label editor to pre-configure your cable testing projects</li>
<li>Press test to automatically sequence up to 1000 cable tests from the local or remote device to increase cable testing efficiency when working alone</li>
<li>Test data cabling for IEEE 802.3 compliance at data rates up to 10 Gb/s (BERT)</li>
<li>Determine signal-to-noise ratio (SNR) for compliance up to 10 Gb/s</li>
<li>Measure delay skew for compliance up to 10Gb/s</li>
<li>Measure length of cable with TDR and capacitance measurements for highly accurate test results and easier troubleshooting</li>
<li>Full-color wire map shows distance to open, distance to short, miswires, split pairs, and shield on a color graphical display</li>
<li>Save test results and generate standards-based measurement reports providing &#8220;Pass/Fail&#8221; indication in pdf, csv, or xml format</li>
</ul>
<header>
<h2 class="h2 ">Perform active network management</h2>
</header>
<div class="ce-textpic ce-left ce-above">
<div class="ce-bodytext">
<ul class="default-list">
<li>Support for IPv4 and IPv6</li>
<li>Discover your network and see the connected network devices</li>
<li>Identifies defective PoE switches with a PoE load test</li>
<li>DHCP test</li>
<li>Ping lists can be defined and saved for later use</li>
<li>LLDP/CDP detection and analysis</li>
<li>Identifies VLANs present in your network</li>
<li>Data transfer from the tester to the PC using USB stick, wireless, or bluetooth connectivity</li>
</ul>
</div>
</div>
</div>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b436a44-34e9" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b436a44-34e9" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Details Techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td class="si-detail-list-title ">Length Measurement Technology</td>
<td class="si-detail-list-description">Time-Domain Reflectometry (TDR) and capacitance</td>
</tr>
<tr>
<td class="si-detail-list-title ">Cable Measurements</td>
<td class="si-detail-list-description">Cable Testing and ID: up to 1,000 ft (305 m)<br />
Split Pair Detection: 3 ft (1 m) to 1,000 ft (305 m)<br />
Length Measurement: 0 to 1,500 ft (457 m), ± (5%+1ft (30 cm))<br />
Distance to fault: 0 to 656 ft (200 m) ± (5% + 3ft (1m))<br />
Supports 8 wiremap remotes (RJ 45) and 24 RJ-45 ID only<br />
remotes</td>
</tr>
<tr>
<td class="si-detail-list-title ">Power over Ethernet (PoE)</td>
<td class="si-detail-list-description">Test supports IEEE 802.3af PoE (Type 1, max 15.4W),<br />
IEEE 802.3at PoE+ (Type 2, 30W) and 802.3bt PoE++ (Type 3, 60W)<br />
Future proofed for IEEE 802.3bt Type 4 100W higherpower PoE</td>
</tr>
<tr>
<td class="si-detail-list-title ">Active Ethernet</td>
<td class="si-detail-list-description">Network and test support by interface:<br />
Copper RJ-45 interface –100/1,000/2,500/5,000/10,000 Mb/sec link speeds<br />
Fiber SFP+ #1 interface supports 10Gb/sec link speed<br />
Fiber SFP+ #2 interface supports 1Gb/sec link speed<br />
WiFi 802.11 a/b/g/n 2.4 Ghz WiFi and Bluetooth</td>
</tr>
<tr>
<td class="si-detail-list-title ">Maximum Voltages</td>
<td class="si-detail-list-description">Maximum voltage that can be applied to any 2 connector pins without causing damage to the tester:<br />
RJ-45: 60 VDC or 50 VAC</td>
</tr>
<tr>
<td class="si-detail-list-title ">Save Test Results</td>
<td class="si-detail-list-description">Stores virtually unlimited cable or network tests with user defined names per project</td>
</tr>
<tr>
<td class="si-detail-list-title ">Tone Generation</td>
<td class="si-detail-list-description">Tone Frequencies: 730 Hz and 1440 Hz</td>
</tr>
<tr>
<td class="si-detail-list-title ">Languages</td>
<td class="si-detail-list-description">English, German, French, Spanish</td>
</tr>
<tr>
<td class="si-detail-list-title ">Battery</td>
<td class="si-detail-list-description">Li-Ion, 7.2 VDC, 3.1A-hr (typical)<br />
Battery Life at 10Gb: 5 hrs minimum, 24 hrs stand-by</td>
</tr>
<tr>
<td class="si-detail-list-title ">Temperature</td>
<td class="si-detail-list-description">Operating: 14 to 140° F (-10 to 60°C)<br />
Storage: -22 to 158°F (-30 to 70°)</td>
</tr>
<tr>
<td class="si-detail-list-title ">Humidity</td>
<td class="si-detail-list-description">10 to 90% non-condensing</td>
</tr>
<tr>
<td class="si-detail-list-title ">Enclosure</td>
<td class="si-detail-list-description">Injection molded plastic</td>
</tr>
<tr>
<td class="si-detail-list-title ">Display</td>
<td class="si-detail-list-description">7&#8243; Color TFT-LCD capacitive touch display,<br />
1024 x 600 resolution (WSVGA)</td>
</tr>
<tr>
<td class="si-detail-list-title ">Size</td>
<td class="si-detail-list-description">245 x 177 x 73 mm (main unit)<br />
130 x 177 x 55 mm (Active Remote)</td>
</tr>
<tr>
<td class="si-detail-list-title ">Weight with Battery</td>
<td class="si-detail-list-description">2.6lbs (1.2 kg) main unit<br />
1.3lbs (0.6 kg) Active Remote</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="Downloads" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#Downloads" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargement</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Document</strong></p>
<ul>
<li><a href="https://www.atevatech.net/Datasheet.pdf">NetXpert Datasheet</a></li>
<li><a href="https://www.atevatech.net/NetXpert_UM.pdf">NetXpert User Manua</a><a href="https://www.atevatech.net/NetXpert_UM.pdf">l</a></li>
<li><a href="https://www.atevatech.net/NetXpert_QuickStart.pdf">NetXpert Quick Start Manual</a></li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="references" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#references" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2020/02/Netxpert_XG_Version_comparison.png" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/netxpertxg/">NetXpertXG</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Logiciel datacheck analyzer : pour diagnostic Ethernet industriel</title>
		<link>https://www.atevatech.net/fr/datacheck-analyzer-software-product-bundle-for-mobile-industrial-ethernet-diagnostics/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=datacheck-analyzer-software-product-bundle-for-mobile-industrial-ethernet-diagnostics</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Fri, 19 Oct 2018 05:21:24 +0000</pubDate>
				<category><![CDATA[Ethernet IP]]></category>
		<category><![CDATA[Modbus TCP]]></category>
		<category><![CDATA[Monitoring systems PROFINET]]></category>
		<category><![CDATA[PROFINET Tester]]></category>
		<category><![CDATA[SOFTING]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=7084</guid>

					<description><![CDATA[<p>Logiciel de diagnostic mobile et tests de réseaux industriels pour Profinet, Modbus et Ethernet/IP</p>
The post <a href="https://www.atevatech.net/fr/datacheck-analyzer-software-product-bundle-for-mobile-industrial-ethernet-diagnostics/">Logiciel datacheck analyzer : pour diagnostic Ethernet industriel</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>Analyzer IE / PRO</h1>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3>Software for Mobile Diagnostics and Acceptance Testing of Industrial Networks</h3>
<p>Analyzer IE / PRO is a comprehensive software solution for acceptance testing and efficient troubleshooting of Ethernet-based industrial communication. In a PROFINET environment, the mobile diagnostic tool generates standardized acceptance reports in accordance with the recommendations of PROFIBUS &amp; PROFINET International (PI), making it an easy-to-use product that is tailored to the needs of plant suppliers, maintenance personnel as well as service providers.</p>

		</div>
	</div>
<div class="wpb_gallery wpb_content_element vc_clearfix wpb_content_element" ><div class="wpb_wrapper"><div class="wpb_gallery_slides wpb_image_grid" data-interval="3"><ul class="wpb_image_grid_ul"><li class="isotope-item"><img decoding="async"  src="https://ca.atevatech.com/wp-content/uploads/sites/3/2018/10/csm_AnalyzerIE-PRO_application_DB_1000px_EN_31c3a74144.jpg" loading="lazy" /></li></ul></div></div></div></div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2018/10/csm_BCAnalyzerIE_D_EN_1701_100_331a6e663f.jpg" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e873d1ad-8391"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e873d1ad-8391"><span class="vc_tta-title-text">Détails techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e873d1ad-8391" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b58ced-e00aa190-e873d1ad-8391"><span class="vc_tta-title-text">Téléchargements</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e873d1ad-8391" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe8ced-e00aa190-e873d1ad-8391"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849338007-2f5d7957-cc0d8ced-e00aa190-e873d1ad-8391" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849338007-2f5d7957-cc0d8ced-e00aa190-e873d1ad-8391"><span class="vc_tta-title-text">Fomation</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3>Comprehensive Functionality</h3>
<ul>
<li>Diagnostics list, error statistics, network statistics</li>
<li>Enhanced flexibility by supporting online as well as offline mode</li>
<li>Generation, analysis and handling of diagnostic data such as graphical topology, inventory list and reference measurements, also for standard Ethernet components (eg PCs, camera systems)</li>
</ul>
<h3>Automated Generation of Acceptance Test Documents</h3>
<ul>
<li>Time saving by automatically created test reports</li>
<li>Flexible definition of acceptance criteria</li>
<li>Transparent reporting by following PI guidelines</li>
</ul>
<h3>Tool Addressing Complete Plant Lifecycle</h3>
<ul>
<li>Data on network configuration, network communication and diagnostic messages</li>
<li>Error identification for effective troubleshooting (e.g. based on inventory list of network devices)</li>
<li>Chance to support exchange of general project information between end users, EPC contractors, system integrators and maintenance service providers</li>
<li>Seamless integration with Softing diagnostics per-manent monitoring solutions TH SCOPE and TH LINK</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a8ced-e00aa190-e873d1ad-8391" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only" width="100%">
<tbody>
<tr>
<th>Technical Data</th>
<th></th>
</tr>
<tr valign="top">
<td width="34%">Functionality</td>
<td width="66%">
<ul>
<li>Analysis of device logs</li>
<li>Live list, statistics, inventory</li>
<li>Topology and trend analysis</li>
<li>GSDML file support, plaintext messages in diagnostic list</li>
<li>Acceptance measurements and acceptance reports</li>
<li>Reference comparison</li>
<li>Configurable time intervals for automated export of inventory and topology data</li>
<li>Data export via Excel</li>
<li>Configurable Blacklist feature for robust operation</li>
<li>Optional (Analyzer PRO): Telegram analysis: jitter, refresh interval, load ratio</li>
</ul>
</td>
</tr>
<tr valign="top">
<td>Supported Protocols</td>
<td>PROFINET, EtherNet/IP, Modbus TCP</td>
</tr>
<tr valign="top">
<td>Interfaces</td>
<td>
<ul>
<li>SNMP Agent</li>
<li>OPC UA Server</li>
</ul>
</td>
</tr>
<tr valign="top">
<td>System Requirements</td>
<td>Adobe Reader 8 or higher for reading the documentation and for printing the topology</td>
</tr>
<tr valign="top">
<td>Supported Operating Systems</td>
<td>Windows 7, Windows 8.1, Windows 10<br />
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016</td>
</tr>
<tr valign="top">
<td>Network Access</td>
<td>Data collection through TH LINK PC (PROFINET, EtherNet/IP, Modbus TCP)</td>
</tr>
<tr valign="top">
<td>Demo Version</td>
<td>Full TH SCOPE functionality can be used for free for 30 days after installation</td>
</tr>
<tr valign="top">
<td>Licensing</td>
<td>Software or hardware key</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b58ced-e00aa190-e873d1ad-8391" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b58ced-e00aa190-e873d1ad-8391" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargements</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>
<h4>Drivers &amp; Software</h4>
<ul>
<li class="download"><a href="http://f002.backblazeb2.com/file/atevatechnologie/SOFTING/AnalyserPRO/dataCHECK_Analyzer_v3.5_IE32.exe" rel="shadowbox;height=555;width=550"> Network Diagnostics dataCHECK Analyzer V3.5 (Installation for 32-Bit-Systems) </a></li>
<li class="download"><a href="http://f002.backblazeb2.com/file/atevatechnologie/SOFTING/AnalyserPRO/dataCHECK_Analyzer_v3.5_IE64.exe" rel="shadowbox;height=555;width=550"> Network Diagnostics dataCHECK Analyzer V3.5 (Installation for 64-Bit-Systems) </a></li>
</ul>
</li>
<li>
<h4>Manuals &amp; Documentation</h4>
<ul>
<li class="download"><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/10/bcAnalyzerIE_I_EN.pdf" target="_blank" rel="noopener">Network Diagnostics dataCHECK Analyzer Installation Manual</a></li>
</ul>
</li>
<li>
<h4>Data Sheets</h4>
<ul>
<li class="download"><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/10/AnalyzerIE-PRO_D_EN_180524_300.pdf" target="_blank" rel="noopener">Network Diagnostics dataCHECK Analyzer IE / PRO Datasheet</a></li>
</ul>
</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe8ced-e00aa190-e873d1ad-8391" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe8ced-e00aa190-e873d1ad-8391" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th colspan="2">Scope of Delivery</th>
</tr>
<tr valign="top">
<td width="34%">Software</td>
<td width="66%">Analyzer IE</td>
</tr>
<tr valign="top">
<td>License</td>
<td>Software key (bound to PC) or hardware key</td>
</tr>
<tr valign="top">
<td rowspan="1">Hardware</td>
<td rowspan="1">profiTap: Network tap for telegram analysis operation, optional (Analyzer PRO)</td>
</tr>
<tr valign="top">
<td>Documentation</td>
<td>Installation manual, user manual, release note</td>
</tr>
</tbody>
</table>
<table class="contenttable stacktable large-only" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th colspan="2">Order Numbers</th>
</tr>
<tr valign="top">
<td width="34%">LRA-JY-003041</td>
<td width="66%">Analyzer IE (software key)</td>
</tr>
<tr valign="top">
<td>LRL-JY-003042</td>
<td>Analyzer IE (hardware key)</td>
</tr>
<tr valign="top">
<td>KPL-JY-003043</td>
<td>Analyzer PRO</td>
</tr>
</tbody>
</table>
<table class="contenttable stacktable large-only" border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th colspan="2">Additional Products and Services</th>
</tr>
<tr valign="top">
<td width="34%">GEA-JN-003006</td>
<td width="66%">TH LINK PROFIBUS</td>
</tr>
<tr valign="top">
<td>GDA-JA-003034</td>
<td>TH LINK PROFINET</td>
</tr>
<tr valign="top">
<td>GDA-JY-003037</td>
<td>TH LINK Industrial Ethernet</td>
</tr>
<tr valign="top">
<td>LRA-JY-003028</td>
<td>TH LINK PC Industrial Ethernet</td>
</tr>
<tr valign="top">
<td>TRA-PB-TECH</td>
<td>Training “PROFIBUS Technology”</td>
</tr>
<tr valign="top">
<td>TRA-PB-TS</td>
<td>Training “PROFIBUS Troubleshooting with exam to Certified PROFIBUS Installer”</td>
</tr>
<tr valign="top">
<td>TRA-PN-CERTINST</td>
<td>Training “PROFINET Acceptance and Commissioning”</td>
</tr>
<tr valign="top">
<td>TRA-PN-CERTENG</td>
<td>Training “PROFINET Technology graduated as Certified PROFINET Engineer”</td>
</tr>
<tr valign="top">
<td rowspan="1">TRA-PN-TOOLS</td>
<td rowspan="1">On-site training: PROFINET tools</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849338007-2f5d7957-cc0d8ced-e00aa190-e873d1ad-8391" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849338007-2f5d7957-cc0d8ced-e00aa190-e873d1ad-8391" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Fomation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Pour les formations, veuillez nous contacter</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Les personnes intéressées par ce produit, peuvent être aussi interessées par :<br />
</strong></p>
<ul>
<li><a href="https://www.atevatech.net/thlink-industrial-ethernet/">THLink Industrial Ethernet</a></li>
<li><a href="https://www.atevatech.net/thlink-profinet/">THLink Profinet</a></li>
<li><a href="https://www.atevatech.net/thscope/">THScope</a></li>
</ul>
<p>&nbsp;</p>

		</div>
	</div>
</div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/datacheck-analyzer-software-product-bundle-for-mobile-industrial-ethernet-diagnostics/">Logiciel datacheck analyzer : pour diagnostic Ethernet industriel</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>THScope ( Logiciel )</title>
		<link>https://www.atevatech.net/fr/thscope/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=thscope</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 06 Jun 2018 19:12:10 +0000</pubDate>
				<category><![CDATA[FDT/DTM]]></category>
		<category><![CDATA[HART]]></category>
		<category><![CDATA[Modbus TCP]]></category>
		<category><![CDATA[PROFIBUS-DEBUG]]></category>
		<category><![CDATA[PROFINET Tester]]></category>
		<category><![CDATA[SOFTING]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=3040</guid>

					<description><![CDATA[<p>Logiciel THScope pour le management de réseaux Industriels et réseaux de diagnostics</p>
The post <a href="https://www.atevatech.net/fr/thscope/">THScope ( Logiciel )</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Management and Diagnostics for Industrial Networks</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h6>TH SCOPE is a software product for industrial network management and network diagnostics. Geared to plant operators and maintenance personnel, TH SCOPE is an all-in-one, easy-to-use solution for permanent monitoring and predictive maintenance, for acceptance testing and for troubleshooting. Combined with TH LINK components, the product supports<a href="https://www.atevatech.net/th-link-profibus/" target="_blank" rel="noopener noreferrer"> PROFIBUS</a>, PROFINET, EtherNet/IP and Modbus TCP protocols.</h6>
<h5><strong><span class="ce-sword">Th</span>e PROFINET Commissioning Report functionality is now available in new <span class="ce-sword">TH</span><span class="ce-sword">SCOPE</span> Release. Download <span class="ce-sword">th</span>e new <span class="ce-sword">TH</span><span class="ce-sword">SCOPE</span> under &#8216;Downloads&#8217; section.</strong></h5>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://www.atevatech.net/wp-content/uploads/2018/06/csm_THScope_D_EN_160401_300_9e86a142a3.jpg" width="865" height="404" alt="csm_THScope_D_EN_160401_300_9e86a142a3" title="csm_THScope_D_EN_160401_300_9e86a142a3" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecbad09-0639" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecbad09-0639"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b43ad09-0639" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b43ad09-0639"><span class="vc_tta-title-text">Technical details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320754302-7b727c18-3cf0ad09-0639" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320754302-7b727c18-3cf0ad09-0639"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320782574-3b588c5e-ffd4ad09-0639" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320782574-3b588c5e-ffd4ad09-0639"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1528305926698-97a712b3-77f3" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1528305926698-97a712b3-77f3"><span class="vc_tta-title-text">FAQ</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1552414358058-ed488140-68f3" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1552414358058-ed488140-68f3"><span class="vc_tta-title-text">Archives</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecbad09-0639" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecbad09-0639" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="articles" class="ui-tabs-panel ui-corner-bottom ui-widget-content" role="tabpanel" aria-labelledby="ui-id-1" aria-hidden="false">
<h3>Versatile Solution for a Wide Variety of Diagnostics Applications</h3>
<ul>
<li>Network commissioning, acceptance testing</li>
<li>Stationary operation for continuous monitoring</li>
<li>Fault localization and identification in case of failure</li>
</ul>
<h3>Comprehensive Representation and Analysis of Diagnostic Data</h3>
<ul>
<li>Data on network communication (e.g. load, error statistics)</li>
<li>Data from network configuration (e.g. device names, firmware versions, topology)</li>
<li>Diagnostic messages (network and device diagnostics)</li>
<li>Data collection also from standard Ethernet devices (e.g. PCs or camera systems)</li>
</ul>
<h3>Optimized for Maintenance Users</h3>
<ul>
<li>Easy and intuitive handling and operation</li>
<li>No expert knowledge of IT or networks required</li>
<li>Support of various network protocols (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP)</li>
</ul>
<h3>Flexible Integration into Existing Systems and Processes</h3>
<ul>
<li>Integration of network data into monitoring tools and supervisory control systems via SNMP or OPC</li>
<li>Export of all diagnostic data, support of further processing in applications such as Excel</li>
<li>Web-based access, local or remote</li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b43ad09-0639" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b43ad09-0639" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only" width="100%">
<tbody>
<tr>
<th colspan="2" valign="top"></th>
</tr>
<tr>
<td valign="top" width="34%">Functionality</td>
<td valign="top" width="66%">
<ul>
<li>Network overview with network and device status plus diagnostic messages with troubleshooting recommendations</li>
<li>Analysis of device logs</li>
<li>Live list, statistics, inventory</li>
<li>GSDML file support, plaintext messages in diagnostic list</li>
<li>Topology and trend analysis</li>
<li>Automatic e-mail notification in case of fault</li>
<li>Reference comparison</li>
<li>Acceptance measurements and acceptance reports</li>
<li>Data export via Excel</li>
</ul>
</td>
</tr>
<tr>
<td valign="top">Supported Protocols</td>
<td valign="top">PROFIBUS (TH SCOPE V2.2),<br />
PROFINET, EtherNet/IP, Modbus TCP (TH SCOPE V2.2 and TH SCOPE V3.0)</td>
</tr>
<tr>
<td valign="top">Interfaces</td>
<td valign="top">
<ul>
<li>SNMP Agent</li>
<li>OPC Classic DA Server</li>
</ul>
</td>
</tr>
<tr>
<td valign="top">System Requirements</td>
<td valign="top">
<ul>
<li>Web browser with Adobe Flash Player 14 or higher<br />
(for TH SCOPE V2.2, not required for TH SCOPE V3.0)</li>
<li>Adobe Reader 8 or higher for reading the documentation and for printing the topology</li>
</ul>
</td>
</tr>
<tr>
<td valign="top">Supported Operating Systems</td>
<td valign="top">Windows 7, Windows 8, Windows 8.1,<br />
Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2</td>
</tr>
<tr>
<td valign="top">Network Access</td>
<td valign="top">Data collection through TH LINK (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP and Industrial Ethernet)</td>
</tr>
<tr>
<td valign="top">Demo Version</td>
<td valign="top">Full TH SCOPE functionality can be used for free for 30 days after installation</td>
</tr>
<tr>
<td valign="top">Licensing</td>
<td valign="top">Via software or hardware key</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320754302-7b727c18-3cf0ad09-0639" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320754302-7b727c18-3cf0ad09-0639" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Documentations</strong></p>
<ul>
<li><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/10/TH_SCOPE_D_EN_180524_400.pdf">Datasheet</a></li>
<li><a href="https://www.atevatech.net/wp-content/uploads/2019/04/TH_SCOPE_U_V3_61_EN.pdf" target="_blank" rel="noopener noreferrer">TH Scope User Manual</a> v 3.60</li>
</ul>
<p><strong>Software</strong></p>
<ul>
<li><a href="https://www.atevatech.net/wp-content/uploads/2019/03/TH_SCOPE_R_EN_3.6.0.pdf" target="_blank" rel="noopener noreferrer">Release note ( TH Scope v 3.60 )</a></li>
<li><a href="https://www.atevatech.net/Latest_install32_THSCope" target="_blank" rel="noopener noreferrer">Network Diagnostrics TH Scope v 3.60 ( installation for 32 Bit-systems )</a></li>
<li><a href="https://www.atevatech.net/wp-content/uploads/exe/Softing/DIVERS/install64_TH_SCOPE_V3.60.exe" target="_blank" rel="noopener noreferrer">Network Diagnostrics TH Scope v 3.60 ( installation for 64 Bit-systems )</a></li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320782574-3b588c5e-ffd4ad09-0639" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320782574-3b588c5e-ffd4ad09-0639" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only" width="100%">
<tbody>
<tr>
<th colspan="2"> Scope of Delivery</th>
</tr>
<tr>
<td width="34%">Software</td>
<td width="66%">TH SCOPE (by download from Softing‘s website)</td>
</tr>
<tr>
<td>License</td>
<td>Software or hardware key</td>
</tr>
<tr>
<td>Documentation</td>
<td>Installation Manual, User Manual, Release Note</td>
</tr>
</tbody>
</table>
<table class="contenttable stacktable large-only" width="100%">
<tbody>
<tr>
<th colspan="2">Order Numbers</th>
</tr>
<tr>
<td width="34%">ATV-LRA-JY-003024</td>
<td width="66%">TH SCOPE (software key)</td>
</tr>
<tr>
<td>ATV-LRL-JY-003025</td>
<td>TH SCOPE (hardware key)</td>
</tr>
</tbody>
</table>
<table class="contenttable stacktable large-only" width="100%">
<tbody>
<tr>
<th colspan="2">Additional Products and Services</th>
</tr>
<tr>
<td width="34%">ATV-GEA-JN-003006</td>
<td width="66%">TH LINK PROFIBUS</td>
</tr>
<tr>
<td>ATV-GDA-JA-003034</td>
<td>TH LINK PROFINET</td>
</tr>
<tr>
<td>ATV-GDA-JY-003037</td>
<td>TH LINK Industrial Ethernet</td>
</tr>
<tr>
<td>ATV-LRA-JY-003028</td>
<td>TH LINK PC Industrial Ethernet</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1528305926698-97a712b3-77f3" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1528305926698-97a712b3-77f3" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">FAQ</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><b>TH SCOPE:</b><br />
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.</p>
<ul>
<li>Enabling of HTTP port 80 &#8211; inbound and outbound</li>
<li>Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).</li>
<li>Enabling of IP 224.0.5.128 port 2364 UDP outbound</li>
<li>Enabling of UDP ports 2365 outbound and 2366 inbound</li>
</ul>
<p>&nbsp;</p>
<p>The following ports are used by TH SCOPE for internal communication only:</p>
<ul>
<li>Port 22</li>
<li>Port 80</li>
<li>Port 1100</li>
<li>Ports 1123 &#8211; 1151</li>
<li>Port 1500</li>
<li>Port 1501</li>
<li>Ports 2363 &#8211; 2366</li>
<li>Ports 49152 &#8211; 49171</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1552414358058-ed488140-68f3" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1552414358058-ed488140-68f3" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Archives</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>V 3.50</strong></p>
<ul>
<li><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/06/TH_SCOPE_U_EN_V3_50.pdf">THScope v 3.50 User manual</a></li>
<li>Release Note 3.50</li>
<li><a href="http://f002.backblazeb2.com/file/atevatechnologie/SOFTING/THScope/Install64_TH_SCOPE_V3.5.exe" target="_blank" rel="noopener noreferrer">THScope V 3.50</a></li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>People interested in this product, can be interested in :</p>
<ul>
<li><a href="https://www.atevatech.net/th-link-profinet/">THLink PROFINET</a></li>
<li><a href="https://www.atevatech.net/th-link-profibus/">THLink PROFIBUS</a></li>
<li><a href="https://www.atevatech.net/thlink-industrial-ethernet/">THLink Industrial Ethernet</a></li>
</ul>

		</div>
	</div>
</div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/thscope/">THScope ( Logiciel )</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>THLink &#8211; Industrial Ethernet</title>
		<link>https://www.atevatech.net/fr/thlink-industrial-ethernet/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=thlink-industrial-ethernet</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Tue, 29 May 2018 22:18:13 +0000</pubDate>
				<category><![CDATA[ETHERNET-Testeur]]></category>
		<category><![CDATA[Ethernet IP]]></category>
		<category><![CDATA[Modbus TCP]]></category>
		<category><![CDATA[Monitoring systems PROFINET]]></category>
		<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[PROFINET Tester]]></category>
		<category><![CDATA[SOFTING]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=2760</guid>

					<description><![CDATA[<p>Outil de diagnostic pour réseaux Ethernet Industriels ( PROFINET/ Modbus TCP/ Ethernet IP ) indépendant du contrôleur  et non intrusif</p>
The post <a href="https://www.atevatech.net/fr/thlink-industrial-ethernet/">THLink – Industrial Ethernet</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h1>Outil de diagnostic : Industrial Ethernet, indépendant du contrôleurs</h1>
<p>Le THLink Industrial Ethernet, permet le contrôle et le diagnostic des réseaux PROFINET, MODBUS TCP et ETHERNET/IP. Les données sont collectées sur un réseua de 254 noeuds et  rendent disponibles ses données via le logiciel  THSCOPE. le THLINK Industrial Ethernet est facile à utiliser et peut être intégré sans interférer avec une installation existante</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://www.atevatech.net/wp-content/uploads/2018/05/csm_THLink_IE_D_EN_170101_311_fbdb7e6c27.jpg" width="847" height="394" alt="csm_THLink_IE_D_EN_170101_311_fbdb7e6c27" title="csm_THLink_IE_D_EN_170101_311_fbdb7e6c27" loading="lazy" /></div>
		</figure>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecb83c9-a525" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecb83c9-a525"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b4383c9-a525" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b4383c9-a525"><span class="vc_tta-title-text">Technical details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320754302-7b727c18-3cf083c9-a525" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320754302-7b727c18-3cf083c9-a525"><span class="vc_tta-title-text">Downloads</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320782574-3b588c5e-ffd483c9-a525" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320782574-3b588c5e-ffd483c9-a525"><span class="vc_tta-title-text">References</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecb83c9-a525" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecb83c9-a525" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3>THLink Industrial Ethernet for an independent Access to PROFINET, EtherNet/IP and Modbus TCP Networks</h3>
<ul>
<li>Controller-independent</li>
<li>Independent of configuration tools</li>
<li>Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers</li>
</ul>
<h3>THLink Industrial Ethernet has been designed for Installation without Interference with Plant Operation</h3>
<ul>
<li>Connection to free port in industrial network, also possible during operation of the plant</li>
<li>No need to install TAPs or use mirror ports</li>
<li>Highest security (separate accesses for control room level and plant level, no routing)</li>
<li>Easy integration into existing plants thanks to compact design</li>
</ul>
<h3>Powerful Data Collection Capabilities Optimized for Ethernet-Based Industrial Communication</h3>
<ul>
<li>Support of the PROFINET, EtherNet/IP and Modbus TCP protocols</li>
<li>Collection also from standard Ethernet devices (e.g. PCs or camera systems)</li>
<li>PROFINET supervisor in PROFINET networks</li>
<li>Network load limit according to PROFINET guidelines</li>
</ul>
<h3>Optimized for Use by Maintenance Engineers, thanks to the THLink industrial Ethernet</h3>
<ul>
<li>Suitable for network acceptance testing, continuous monitoring and troubleshooting</li>
<li>Easy and intuitive handling and operation</li>
<li>Fault identification with intelligent troubleshooting assistance</li>
<li>Seamless integration with TH SCOPE diagnostics software</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b4383c9-a525" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b4383c9-a525" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /></colgroup>
<tbody>
<tr>
<td rowspan="1">Functionality</td>
<td rowspan="1">
<ul>
<li>Network detection and data collection</li>
<li>Alarm notification in case of fault</li>
<li>Basic monitoring, configuration</li>
<li>Integrated web server</li>
</ul>
</td>
</tr>
<tr>
<td>Input Voltage</td>
<td>24 VDC (18 VDC … 32 VDC)</td>
</tr>
<tr>
<td rowspan="1">Current consumption</td>
<td rowspan="1">max. 180 mA</td>
</tr>
<tr>
<td rowspan="1">Current consumption relay contact</td>
<td rowspan="1">max. 100 mA</td>
</tr>
<tr>
<td rowspan="1">Operating Temperature</td>
<td rowspan="1">-40 °C … +75 °C</td>
</tr>
<tr>
<td rowspan="1">Relative Air Humidity</td>
<td rowspan="1">5 … 95 % (no condensation)</td>
</tr>
<tr>
<td rowspan="1">Ethernet Ports</td>
<td rowspan="1">RJ-45 (10Base-T/100Base-TX)</td>
</tr>
<tr>
<td rowspan="1">Supported SD Cards</td>
<td rowspan="1">See Release Notes</td>
</tr>
<tr>
<td rowspan="1">Mounting</td>
<td rowspan="1">35 mm DIN rail</td>
</tr>
<tr>
<td rowspan="1">Dimensions (HxWxD)</td>
<td rowspan="1">22.5 x 99 x 114.5 mm</td>
</tr>
<tr>
<td rowspan="1">Weight</td>
<td rowspan="1">120 g</td>
</tr>
<tr>
<td rowspan="1">Certifications</td>
<td rowspan="1">CE</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320754302-7b727c18-3cf083c9-a525" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320754302-7b727c18-3cf083c9-a525" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Documents:</strong></p>
<ul>
<li><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/TH_LINK_IE_D_EN_191122_402.pdf" target="_blank" rel="noopener noreferrer">THLink Datasheet</a></li>
<li><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/TH_LINK_ETH_I_EN_L_01.pdf" target="_blank" rel="noopener noreferrer">THLink : Installation Manual  ( Thlink Industrial Ethernet / Profinet / Ethernet IP / Modbus TCP)</a></li>
<li><a href="https://www.atevatech.net/wp-content/uploads/sites/3/2018/05/TH_LINK_MAINTENANCE_TOOL_UserGuide.pdf" target="_blank" rel="noopener noreferrer">THLink : Maintenance tool User Manuel</a></li>
<li><a href="https://www.atevatech.net/wp-content/uploads/2019/03/Audi_IEB91_11-2015.pdf" target="_blank" rel="noopener noreferrer"><em>Full control of communication and Diagnostics at AUDI</em></a></li>
<li>Firmware</li>
</ul>
<p><strong>Logiciel</strong></p>
<ul>
<li><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/Install_TH_Maintenance_Tool.exe">Maintenance tool</a></li>
<li><a href="https://www.atevatech.net/thscope/">TH Scope</a></li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320782574-3b588c5e-ffd483c9-a525" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320782574-3b588c5e-ffd483c9-a525" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /></colgroup>
<tbody>
<tr>
<td>GDA-JY-003037</td>
<td>TH LINK Industrial Ethernet</td>
</tr>
</tbody>
</table>
<h3>Scope of Delivery</h3>
<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /></colgroup>
<tbody>
<tr>
<td>Hardware</td>
<td>TH LINK Industrial Ethernet</td>
</tr>
<tr>
<td rowspan="1">Documentation</td>
<td rowspan="1">Installation Manual, Release Note (by download)</td>
</tr>
</tbody>
</table>
<h3>Additional Products and Services</h3>
<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /></colgroup>
<tbody>
<tr>
<td>ATV-LRA-JY-003024</td>
<td><a href="http://industrial.softing.com/en/products/network-health/installed-permanent-monitoring/industrial-ethernet/th-scope-management-and-diagnostics-of-industrial-ethernet-networks.html">TH SCOPE</a> (software key)</td>
</tr>
<tr>
<td rowspan="1">ATV-LRL-JY-003025</td>
<td rowspan="1">TH SCOPE (hardware key)</td>
</tr>
<tr>
<td rowspan="1">ATV-LRA-JY-003028</td>
<td rowspan="1">TH LINK PC Industrial Ethernet (software key)</td>
</tr>
<tr>
<td rowspan="1">ATV-LRL-JY-003029</td>
<td rowspan="1">TH LINK PC Industrial Ethernet (hardware key)</td>
</tr>
<tr>
<td rowspan="1">ATV-TRA-PN-TECH</td>
<td rowspan="1">Training “PROFINET Technology”</td>
</tr>
<tr>
<td rowspan="1">ATV-TRA-PN-CERTENG</td>
<td rowspan="1">Training “PROFINET Commissioning and Troubleshooting”</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/thlink-industrial-ethernet/">THLink – Industrial Ethernet</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>THLink &#8211; PROFINET</title>
		<link>https://www.atevatech.net/fr/thlink-profinet/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=thlink-profinet</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Wed, 12 Oct 2016 21:44:48 +0000</pubDate>
				<category><![CDATA[PROFINET]]></category>
		<category><![CDATA[PROFINET Tester]]></category>
		<category><![CDATA[SOFTING]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=193</guid>

					<description><![CDATA[<p>Système de Monitoring de réseaux PROFINET</p>
The post <a href="https://www.atevatech.net/fr/thlink-profinet/">THLink – PROFINET</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>PROFINET : THLink Profinet</h2>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/2016/10/Softing_TH_Scope_TH_Link_rgb_72dpi_600px.jpg" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div class="csc-textpic-text">
<div class="innerContentWrap">
<h2>Diagnostic PROFINET : Indépendant du contrôleur</h2>
<p>L&#8217;outil de diagnostic THLink PROFINET est totalement indépendant du contrôleur. Il permet le &#8220;monitoring&#8221; des réseaux PROFINET.  Les données sont collectés dans des réseaux comprenant jusqu&#8217;à 254 Noeuds et mise à la disposition des utilisateurs via le logiciel THScope. THLink PROFINET facile d&#8217;utilisations&#8217;intègre facilement sans intéraction avec le fonctionnement de l&#8217;installation existante.</p>
</div>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-modern vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1441874172163-094e5af5-15d53ae8-d10a29b8-109f" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172163-094e5af5-15d53ae8-d10a29b8-109f"><span class="vc_tta-title-text">Général</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1441874172283-f430400e-9d323ae8-d10a29b8-109f" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1441874172283-f430400e-9d323ae8-d10a29b8-109f"><span class="vc_tta-title-text">Détails techniques</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849058672-84c495bf-43b529b8-109f" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849058672-84c495bf-43b529b8-109f"><span class="vc_tta-title-text">Téléchargements</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849135016-9296723c-2afe29b8-109f" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849135016-9296723c-2afe29b8-109f"><span class="vc_tta-title-text">Numéro de référence</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1475849171874-4dab6cc8-a76129b8-109f" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1475849171874-4dab6cc8-a76129b8-109f"><span class="vc_tta-title-text">Formation</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1593500985305-4c6e5afa-2c36" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1593500985305-4c6e5afa-2c36"><span class="vc_tta-title-text">Wiki</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1441874172163-094e5af5-15d53ae8-d10a29b8-109f" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172163-094e5af5-15d53ae8-d10a29b8-109f" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Général</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="articles" class="ui-tabs-panel ui-widget-content ui-corner-bottom">
<h4><strong>Independent Access to PROFINET Network</strong></h4>
<ul>
<li>Controller-independent</li>
<li>Independent of configuration tools</li>
<li>Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers)</li>
</ul>
<h4><strong>Designed for Installation without Interference with Plant Operation</strong></h4>
<ul>
<li>Connection to free port in PROFINET network, also possible during operation of the plant</li>
<li>No need to install TAPs or use mirror ports</li>
<li>Highest security (separate accesses for control room level and plant level, no routing)</li>
<li>Easy integration into existing plants thanks to compact design</li>
</ul>
<h4><strong>Powerful Data Collection Capabilities Optimized for PROFINET</strong></h4>
<ul>
<li>Collection from PROFINET devices and other nodes (e.g. PCs or camera systems)</li>
<li>PROFINET supervisor in PROFINET networks</li>
<li>Network load limit according to PROFINET guidelines</li>
</ul>
<h4><strong>Optimized for Use by Maintenance Engineers</strong></h4>
<ul>
<li>Suitable for network acceptance testing, continuous monitoring and troubleshooting</li>
<li>Easy and intuitive handling and operation</li>
<li>Fault identification with intelligent troubleshooting assistance</li>
<li>Seamless integration with <a href="https://www.atevatech.net/thscope/">TH SCOPE diagnostics software</a></li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1441874172283-f430400e-9d323ae8-d10a29b8-109f" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1441874172283-f430400e-9d323ae8-d10a29b8-109f" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Détails techniques</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /> </colgroup>
<tbody>
<tr>
<td rowspan="1">Functionality</td>
<td rowspan="1">
<ul>
<li>Network detection and data collection (active/passive for PROFINET Networks)</li>
<li>Alarm notification in case of fault</li>
<li>Basic monitoring, configuration</li>
<li>Integrated web server</li>
</ul>
</td>
</tr>
<tr>
<td>Input Voltage</td>
<td>24 VDC (18 VDC … 32 VDC)</td>
</tr>
<tr>
<td rowspan="1">Current consumption</td>
<td rowspan="1">max. 180 mA</td>
</tr>
<tr>
<td rowspan="1">Current consumption relay contact</td>
<td rowspan="1">max. 100 mA</td>
</tr>
<tr>
<td rowspan="1">Operating Temperature</td>
<td rowspan="1">-40 °C … +75 °C</td>
</tr>
<tr>
<td rowspan="1">Relative Air Humidity</td>
<td rowspan="1">5 … 95 % (no condensation)</td>
</tr>
<tr>
<td rowspan="1">Ethernet Ports</td>
<td rowspan="1">RJ-45 (10Base-T/100Base-TX)</td>
</tr>
<tr>
<td rowspan="1">Supported SD Cards</td>
<td rowspan="1">See Release Notes</td>
</tr>
<tr>
<td rowspan="1">Mounting</td>
<td rowspan="1">35 mm DIN rail</td>
</tr>
<tr>
<td rowspan="1">Dimensions (HxWxD)</td>
<td rowspan="1">22.5 x 99 x 114.5 mm</td>
</tr>
<tr>
<td rowspan="1">Weight</td>
<td rowspan="1">120 g</td>
</tr>
<tr>
<td rowspan="1">Certifications</td>
<td rowspan="1">CE</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849058672-84c495bf-43b529b8-109f" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849058672-84c495bf-43b529b8-109f" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Téléchargements</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li>
<h4>Data Sheets</h4>
<ul>
<li class="download"><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/TH_LINK_IE_D_EN_191122_402.pdf" target="_blank" rel="noopener noreferrer">PROFINET Diagnostics TH LINK PROFINET Data Sheet</a></li>
</ul>
</li>
<li>
<h4>Drivers &amp; Software</h4>
<ul>
<li class="download"><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/firmware4_4_0_0.zip" target="_blank" rel="noopener noreferrer">PROFINET Diagnostics TH LINK PROFINET Firmware Update V4.1</a></li>
</ul>
</li>
<li>
<h4>Manuals &amp; Documentation</h4>
<ul>
<li class="download"><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/TH_LINK_ETH_I_EN_L_01.pdf" target="_blank" rel="noopener noreferrer">PROFINET Diagnostics TH LINK PROFINET Installation Manual</a></li>
<li class="download"><a href="https://www.atevatech.net/ftp/softing/THLinkPROFINET/TH_LINK_ETH_ReleaseNote_EN_02.pdf">PROFINET Diagnostics TH LINK PROFINET Release Note V4.10</a></li>
<li class="download"></li>
</ul>
</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849135016-9296723c-2afe29b8-109f" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849135016-9296723c-2afe29b8-109f" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Numéro de référence</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>GDA-JA-003034</td>
<td>TH LINK PROFINET</td>
</tr>
</tbody>
</table>
<h3>Scope of Delivery</h3>
<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /> </colgroup>
<tbody>
<tr>
<td>Hardware</td>
<td>TH LINK PROFINET</td>
</tr>
<tr>
<td rowspan="1">Documentation</td>
<td rowspan="1">Installation Manual, Release Note (by download)</td>
</tr>
</tbody>
</table>
<h3>Additional Products and Services</h3>
<table class="contenttable stacktable large-only">
<colgroup>
<col width="200" />
<col width="400" /> </colgroup>
<tbody>
<tr>
<td>LRA-JY-003024</td>
<td><a href="http://industrial.softing.com/en/products/network-diagnostics/monitoring/profinet/th-scope-management-and-diagnostics-of-profinet-networks.html">TH SCOPE</a> (software key)</td>
</tr>
<tr>
<td rowspan="1">LRL-JY-003025</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/products/network-diagnostics/monitoring/profinet/th-scope-management-and-diagnostics-of-profinet-networks.html">TH SCOPE </a>(hardware key)</td>
</tr>
<tr>
<td rowspan="1">LRA-JY-003028</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/products/network-diagnostics/monitoring/industrial-ethernet/th-link-pc-industrial-ethernet-controller-independent-diagnostics-for-ethernet-based-industrial-networks.html">TH LINK PC Industrial Ethernet</a> (software key)</td>
</tr>
<tr>
<td rowspan="1">LRL-JY-003029</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/products/network-diagnostics/monitoring/industrial-ethernet/th-link-pc-industrial-ethernet-controller-independent-diagnostics-for-ethernet-based-industrial-networks.html">TH LINK PC Industrial Ethernet </a>(hardware key)</td>
</tr>
<tr>
<td rowspan="1">GDA-JY-003037</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/products/network-diagnostics/monitoring/industrial-ethernet/th-link-industrial-ethernet-industrial-ethernet-network-diagnostics-independent-from-controller-and-control-room.html">TH LINK Industrial Ethernet</a></td>
</tr>
<tr>
<td rowspan="1">TRA-PN-TECH</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/services/training/profinet.html">Training “PROFINET Technology”</a></td>
</tr>
<tr>
<td rowspan="1">TRA-PN-CERTENG</td>
<td rowspan="1"><a href="http://industrial.softing.com/en/services/training/profinet.html">Training “PROFINET Commissioning and Troubleshooting”</a></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1475849171874-4dab6cc8-a76129b8-109f" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1475849171874-4dab6cc8-a76129b8-109f" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Formation</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="trainings" class="tab-pane ui-tabs-panel ui-widget-content ui-corner-bottom">
<ul>
<li><a href="http://industrial.softing.com/en/services/training/profinet.html?openTraining=31&amp;cHash=f54dac66ee03fe06a20a343bf4b1be9c">PROFINET Technology Training with Exam for Certified PROFINET Engineer</a></li>
<li><a href="http://industrial.softing.com/en/services/training/profinet.html?openTraining=32&amp;cHash=5fff5ee8cbcb7f6b79f770779931e24a">PROFINET &#8211; Commissioning and Troubleshooting with Exam for Certified PROFINET Installer</a></li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1593500985305-4c6e5afa-2c36" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1593500985305-4c6e5afa-2c36" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Wiki</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="accordion-content-15326" class="accordion-content collapse show" aria-labelledby="accordion-header-15326">
<div id="c14836" class="frame frame-default frame-type-text frame-layout-0">
<p><strong>TH LINK:</strong><br />
enablement of the following ports:</p>
<ul>
<li>HTTP Protocol:      80 TCP</li>
<li>Firmware update: 1100 TCP</li>
<li>communication with each other:    1123, 1124, 2364 UDP</li>
<li>communication with TH SCOPE via Multicast:  2364 UDP</li>
<li>communication with TH SCOPE via Unicast:    1151, 2365 UDP</li>
</ul>
<p>There must be no firewall between the TH LINK and the PROFINET and/or EtherNet/IP devices.</p>
<p><strong>TH SCOPE:</strong><br />
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.</p>
<ul>
<li>Enabling of HTTP port 80 &#8211; inbound and outbound</li>
<li>Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).</li>
<li>Enabling of IP 224.0.5.128 port 2364 UDP outbound</li>
<li>Enabling of UDP ports 2365 outbound and 2366 inbound</li>
</ul>
<p>&nbsp;</p>
<p>The following ports are used by TH SCOPE for internal communication only:</p>
<ul>
<li>Port 22</li>
<li>Port 80</li>
<li>Port 1100</li>
<li>Ports 1123 &#8211; 1151</li>
<li>Port 1500</li>
<li>Port 1501</li>
<li>Ports 2363 &#8211; 2366</li>
<li>Ports 49152 &#8211; 49171</li>
</ul>
</div>
</div>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h3><strong>Produits qui pourrait vous intéresser</strong></h3>
<ul>
<li><a href="https://www.atevatech.net/bc-700-pb">Testeur PROFIBUS</a></li>
<li><a href="https://www.atevatech.net/thlink-industrial-ethernet/">THLink Industrial Ethernet</a></li>
</ul>

		</div>
	</div>
</div></div></div></div>
</div>The post <a href="https://www.atevatech.net/fr/thlink-profinet/">THLink – PROFINET</a> first appeared on <a href="https://www.atevatech.net">ATEVA Technologies</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
