<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>S5 | ATEVA Technologies</title>
	<atom:link href="https://www.atevatech.net/category/s5-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.atevatech.net</link>
	<description>Votre partenaire en réseaux industriels</description>
	<lastBuildDate>Mon, 13 Mar 2023 16:58:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://www.atevatech.net/wp-content/uploads/2021/03/cropped-cropped-ATV_logo_web-32x32.png</url>
	<title>S5 | ATEVA Technologies</title>
	<link>https://www.atevatech.net</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PGMux II eng</title>
		<link>https://www.atevatech.net/pgmux-ii-eng/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=pgmux-ii-eng</link>
		
		<dc:creator><![CDATA[Webmaster]]></dc:creator>
		<pubDate>Mon, 13 Mar 2023 16:45:52 +0000</pubDate>
				<category><![CDATA[S5]]></category>
		<guid isPermaLink="false">https://www.atevatech.net/?p=34480</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Simultaneous Operation of two Devices on one S5 PG Interface</h2>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async"  src="https://www.atevatech.net/wp-content/uploads/sites/3/2018/06/PG-MUXII1-310x310.png" class="vc_single_image-img" loading="lazy"" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>PG-MUX II enables the simultaneous operation of two devices on one S5 PG interface: Connection of programming device, text display, operator panel or other process devices, that understand the PG protocol AS511.</p>
<div class="general-information-middle">
<ul class="component-items">
<li>Interface doubling for PG connection to a SIMATIC S5</li>
<li>Compatible with all S5 controllers including CPU 945. Since physical connection, pin allocation, and the electrical data conform to the PG/PLC interfaces, you can use your regular cables to connect the devices without having to bother with adapters</li>
<li>When two PGs are connected to one PLC, all PG functions except &#8220;process command&#8221; can be executed simultaneously on both PGs</li>
</ul>
</div>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left"><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list" role="tablist"><li class="vc_tta-tab vc_active" data-vc-tab role="presentation"><a href="#1486320650397-1646515a-4ecb1df3-fbee" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650397-1646515a-4ecb1df3-fbee"><span class="vc_tta-title-text">Overview</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320650533-951f3bce-9b431df3-fbee" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320650533-951f3bce-9b431df3-fbee"><span class="vc_tta-title-text">Technical details</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1486320782574-3b588c5e-ffd41df3-fbee" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1486320782574-3b588c5e-ffd41df3-fbee"><span class="vc_tta-title-text">References</span></a></li><li class="vc_tta-tab" data-vc-tab role="presentation"><a href="#1678726209175-1639a291-002a" data-vc-tabs data-vc-container=".vc_tta" role="tab" aria-selected="false" id="tab-1678726209175-1639a291-002a"><span class="vc_tta-title-text">Downloads</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1486320650397-1646515a-4ecb1df3-fbee" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650397-1646515a-4ecb1df3-fbee" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Overview</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<div id="articles" class="ui-tabs-panel ui-corner-bottom ui-widget-content" role="tabpanel" aria-labelledby="ui-id-1" aria-hidden="false">
<ul class="component-items">
<li>Industrial metal housing</li>
<li>All interfaces and control elements in the front</li>
<li>Including connection cable</li>
</ul>
</div>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320650533-951f3bce-9b431df3-fbee" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320650533-951f3bce-9b431df3-fbee" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical details</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>PLC Interface</td>
<td>TTY (20 mA), active</td>
</tr>
<tr>
<td>PG1 + PG 2 Interface</td>
<td>TTY (20 mA), active</td>
</tr>
<tr>
<td>Protocols</td>
<td>2 x AS511 or<br />
1 x SINEC-L1-Bus<br />
and 1 x AS511</td>
</tr>
<tr>
<td>Combinations</td>
<td>
<ul class="component-items">
<li>AS511 (PG Protocol) &#8211; AS511 (PG Protocol)</li>
<li>AS511 (PG Protocol) &#8211; SINEC-L1-BUS</li>
<li>SINEC-L1-BUS  &#8211; AS511 (PG Protocol)</li>
</ul>
</td>
</tr>
<tr>
<td>Power Supply</td>
<td>230 V AC and 24 V DC</td>
</tr>
<tr>
<td>Dimensions[in mm]</td>
<td>L = 190, D = 110, H = 50</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1486320782574-3b588c5e-ffd41df3-fbee" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1486320782574-3b588c5e-ffd41df3-fbee" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">References</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>400-9361-05</td>
<td>PG-MUX II, EURO (230V)</td>
</tr>
</tbody>
</table>
<h3>Additional Products and Services</h3>
<table class="contenttable stacktable large-only">
<tbody>
<tr>
<td>400-9361-03</td>
<td>Connection Cable Multiplexer &#8211; PLC TTY</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1678726209175-1639a291-002a" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1678726209175-1639a291-002a" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Downloads</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li><a href="https://atevatech.aztgrp.net/index.php/s/tJtziifEP9Bmnbe" target="_blank" rel="noopener">PGMux II User Manual </a></li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>People intersted in this product, may be interested in :</strong></p>
<p><a href="https://www.atevatech.net/s5-tcp-ip-100/">S5-TCP/IP-100</a></p>
<p><a href="https://www.atevatech.net/produit/testeur-profibus-pb-t5-bc-700-pb/">Profibus DP Tester</a></p>

		</div>